Reliability of arm wingate anaerobic testing in persons with complete paraplegia

被引:42
作者
Jacobs, PL [1 ]
Mahoney, ET
Johnson, B
机构
[1] Univ Miami, Sch Med, Dept Neurol Surg, Miami Project Cure Paralysis, Miami, FL 33101 USA
[2] Miami Vet Affairs Med Ctr, Ctr Excellence Funct Recovery Chron Spinal Cord I, Miami, FL USA
关键词
Wingate Anaerobic Testing; spinal cord injuries; paraplegia; ergometry; upper extremity power; activities of daily living; arm power; rehabilitation;
D O I
10.1080/10790268.2003.11753674
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Accurate, reliable assessment of upper extremity muscular power in persons with paraplegia caused by spinal cord injury (SCI) would provide an objective indication of their ability to generate the forces necessary for the performance of daily activities. Wingate Anaerobic Testing (WAnT) consists of a 30-second sprint test on a cycle ergometer and has been used widely in both athletic and research settings. Purpose: To examine test-retest reliability of arm WAnT performance in persons with complete SCI and paraplegia. Methods: Forty-three participants with thoracic-level paraplegia (T2 through T12) performed 2 trials of arm WAnT with 2 to 7 days between each trial. Testing was performed using a Monarch 834E ergometer with participants seated in their wheelchairs. Participants were directed to crank at maximal pace for 30 seconds against a resistance load equivalent to 3.5% of their body mass. The SMI OptoSensor 2000 system was used to determine values of peak power (P-peak), mean power (P-mean), minimum power, and rate of fatigue, which were compared between trials using I-way analysis of variance for repeated measures. Coefficients of determination (r(2)) were calculated between trials for P-peak and P-mean Results: No significant difference was found between trials for any of the power output variables. Regression analysis indicated that P-peak and P-mean were closely associated between the 2 trials (r(2) = 0.92 and 0.94, respectively). Conclusion: Arm WAnT is a reliable measurement tool for the assessment of upper extremity muscular power in persons with complete paraplegia.
引用
收藏
页码:141 / 144
页数:4
相关论文
共 27 条
[1]  
*AM SPIN INJ ASS, 1996, INT STAND NEUR CLASS
[2]  
[Anonymous], 1974, INT SERIES SPORTS SC
[3]  
BAROR O, 1977, ISRAEL J MED SCI, V13, P326
[4]  
BAROR O, 1976, P INT SEM MOT LEARN, P310
[5]  
BAROR O, 1978, PHYSICAL FITNESS ASS, P142
[6]  
BLAIR SN, 1994, CARDIOVASCULAR RESPO, P303
[7]  
EVANS J A, 1981, Canadian Journal of Applied Sport Sciences, V6, P53
[8]  
GLASER RM, 1989, MED SCI SPORT EXER, V21, pS149
[9]   Rotator cuff repairs in individuals with paraplegia [J].
Goldstein, B ;
Young, J ;
Escobedo, EM .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 1997, 76 (04) :316-322
[10]  
Hawley J A, 1992, Br J Sports Med, V26, P151