Compact X-Ray Tube With Ceramic Vacuum Seal for Portable and Robust Dental Imaging

被引:6
|
作者
Gupta, Amar Prasad [1 ]
Choi, Jinho [2 ]
Mativenga, Mallory [3 ]
Park, Keunhwa [4 ]
Jang, Jaekyu [5 ]
Yeo, Seung Jun [5 ]
Jung, Jaeik [5 ]
Chae, Moon Shik [6 ]
Lee, Byeong-No [6 ]
Jang, Jejin [7 ]
Zhu, He-Lin [7 ]
Mok, Hyung-Soo [7 ]
Ahn, Jeung Sun [1 ]
Ryu, Jehwang [4 ]
机构
[1] Kyung Hee Univ, Dept Phys, Seoul 02447, South Korea
[2] Kyung Hee Univ, Dept Radiat Oncol, Coll Med, Seoul 02447, South Korea
[3] Kyung Hee Univ, Dept Informat Dis, Seoul 02447, South Korea
[4] Kyung Hee Univ, Dept Radiol, Coll Med, Seoul 02447, South Korea
[5] CAT Beam Tech Co Ltd, Seoul 02455, South Korea
[6] Korea Atom Energy Res Inst, Jeongeup Si 56212, Jeollabuk Do, South Korea
[7] Konkuk Univ, Dept Elect & Engn, Seoul 05029, South Korea
基金
新加坡国家研究基金会;
关键词
Brazing; ceramic; dental; filament; X-ray;
D O I
10.1109/TED.2021.3097315
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A major challenge for glass X-ray tube makers is the reduction in the tube size for portable or handheld applications. Size reduction is difficult mainly due to contact size restrictions for glass-to-metal welding. In high-voltage (60-70 kV) portable applications such as dental imaging, a distance of at least 5 mm should be maintained between the anode and the glass envelope to prevent the latter from burnout, which further limits reduction in the tube's diameter. In this study, reduction in the size of a dental X-ray tube by approximately 43% is achieved by replacing the glass envelope with ceramic. Instead of welding, the ceramic body permits the use of brazing, which supports extremely small contact sizes. Additionally, due to the higher dielectric constant of ceramic, even less than 1 mm spacing is permissible between the envelope and the anode, enabling further size reduction. Despite the 43% reduction in size, limiting spatial resolutions of approximately 8 and 7 lines per mm are obtained for the ceramic and glass sealed tubes, respectively. Moreover, the two tubes obtain similar X-ray images of human teeth, verifying the potential of the compact-size ceramic X-ray tube in dental imaging.
引用
收藏
页码:4705 / 4710
页数:6
相关论文
共 50 条
  • [41] Performance criteria for x-ray imaging sensors
    Fröjdh, C
    Nelvig, P
    PHYSICA MEDICA, 1998, 14 : 10 - 12
  • [42] Energy-resolved x-ray imaging
    Vasin, M. G.
    Ignatiev, Yu. V.
    Lakhtikov, A. E.
    Morovov, A. P.
    Nazarov, V. V.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (6-7) : 648 - 653
  • [43] New type x-ray Imaging intensifier
    Li, Y
    Fu, LC
    Dan, TR
    Jiang, DL
    Duanmu, QD
    Tian, JQ
    ADVANCED MATERIALS AND DEVICES FOR SENSING AND IMAGING, 2002, 4919 : 421 - 423
  • [44] Line focal X-ray source imaging
    Liu Xin
    Yi Ming-Hao
    Guo Jin-Chuan
    ACTA PHYSICA SINICA, 2016, 65 (21)
  • [45] XIPE: the X-ray imaging polarimetry explorer
    Soffitta, Paolo
    Barcons, Xavier
    Bellazzini, Ronaldo
    Braga, Joao
    Costa, Enrico
    Fraser, George W.
    Gburek, Szymon
    Huovelin, Juhani
    Matt, Giorgio
    Pearce, Mark
    Poutanen, Juri
    Reglero, Victor
    Santangelo, Andrea
    Sunyaev, Rashid A.
    Tagliaferri, Gianpiero
    Weisskopf, Martin
    Aloisio, Roberto
    Amato, Elena
    Attina, Primo
    Axelsson, Magnus
    Baldini, Luca
    Basso, Stefano
    Bianchi, Stefano
    Blasi, Pasquale
    Bregeon, Johan
    Brez, Alessandro
    Bucciantini, Niccolo
    Burderi, Luciano
    Burwitz, Vadim
    Casella, Piergiorgio
    Churazov, Eugene
    Civitani, Marta
    Covino, Stefano
    Curado da Silva, Rui Miguel
    Cusumano, Giancarlo
    Dadina, Mauro
    D'Amico, Flavio
    De Rosa, Alessandra
    Di Cosimo, Sergio
    Di Persio, Giuseppe
    Di Salvo, Tiziana
    Dovciak, Michal
    Elsner, Ronald
    Eyles, Chris J.
    Fabian, Andrew C.
    Fabiani, Sergio
    Feng, Hua
    Giarrusso, Salvatore
    Goosmann, Rene W.
    Grandi, Paola
    EXPERIMENTAL ASTRONOMY, 2013, 36 (03) : 523 - 567
  • [46] X-ray phase-contrast imaging
    Endrizzi, Marco
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 878 : 88 - 98
  • [47] Vacuum system of X-ray beamlines of SPring-8
    Ohashi, H
    Goto, S
    Kishimoto, H
    Murase, T
    Isshiki, M
    Suzuki, Y
    Kimura, H
    Takeshita, K
    Ishikawa, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 801 - 804
  • [48] X-ray medical imaging - A centennial perspective
    Sprawls, P
    PHYSICA MEDICA, 1997, 13 : 193 - 196
  • [49] High resolution X-ray imaging with pnCCDs
    Schopper, Florian
    Ninkovic, J.
    Richter, R.
    Schaller, G.
    Selle, T.
    Treis, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 912 : 11 - 15
  • [50] Context sensitive cardiac x-ray imaging: a machine vision approach to x-ray dose control
    Kengyelics, Stephen M.
    Gislason-Lee, Amber J.
    Keeble, Claire
    Magee, Derek R.
    Davies, Andrew G.
    JOURNAL OF ELECTRONIC IMAGING, 2015, 24 (05)