Compact X-Ray Tube With Ceramic Vacuum Seal for Portable and Robust Dental Imaging

被引:6
|
作者
Gupta, Amar Prasad [1 ]
Choi, Jinho [2 ]
Mativenga, Mallory [3 ]
Park, Keunhwa [4 ]
Jang, Jaekyu [5 ]
Yeo, Seung Jun [5 ]
Jung, Jaeik [5 ]
Chae, Moon Shik [6 ]
Lee, Byeong-No [6 ]
Jang, Jejin [7 ]
Zhu, He-Lin [7 ]
Mok, Hyung-Soo [7 ]
Ahn, Jeung Sun [1 ]
Ryu, Jehwang [4 ]
机构
[1] Kyung Hee Univ, Dept Phys, Seoul 02447, South Korea
[2] Kyung Hee Univ, Dept Radiat Oncol, Coll Med, Seoul 02447, South Korea
[3] Kyung Hee Univ, Dept Informat Dis, Seoul 02447, South Korea
[4] Kyung Hee Univ, Dept Radiol, Coll Med, Seoul 02447, South Korea
[5] CAT Beam Tech Co Ltd, Seoul 02455, South Korea
[6] Korea Atom Energy Res Inst, Jeongeup Si 56212, Jeollabuk Do, South Korea
[7] Konkuk Univ, Dept Elect & Engn, Seoul 05029, South Korea
基金
新加坡国家研究基金会;
关键词
Brazing; ceramic; dental; filament; X-ray;
D O I
10.1109/TED.2021.3097315
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A major challenge for glass X-ray tube makers is the reduction in the tube size for portable or handheld applications. Size reduction is difficult mainly due to contact size restrictions for glass-to-metal welding. In high-voltage (60-70 kV) portable applications such as dental imaging, a distance of at least 5 mm should be maintained between the anode and the glass envelope to prevent the latter from burnout, which further limits reduction in the tube's diameter. In this study, reduction in the size of a dental X-ray tube by approximately 43% is achieved by replacing the glass envelope with ceramic. Instead of welding, the ceramic body permits the use of brazing, which supports extremely small contact sizes. Additionally, due to the higher dielectric constant of ceramic, even less than 1 mm spacing is permissible between the envelope and the anode, enabling further size reduction. Despite the 43% reduction in size, limiting spatial resolutions of approximately 8 and 7 lines per mm are obtained for the ceramic and glass sealed tubes, respectively. Moreover, the two tubes obtain similar X-ray images of human teeth, verifying the potential of the compact-size ceramic X-ray tube in dental imaging.
引用
收藏
页码:4705 / 4710
页数:6
相关论文
共 50 条
  • [21] Solar X-ray imaging telescope
    Gaither, CC
    Desai, UD
    MISSIONS TO THE SUN, 1996, 2804 : 274 - 285
  • [22] Hybrid scintillators for x-ray imaging
    Bueno, C
    Rairden, RL
    Betz, RA
    PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 469 - 481
  • [23] Understanding X-ray cargo imaging
    Chen, GY
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 241 (1-4) : 810 - 815
  • [24] X-ray and neutron imaging with colloids
    Waigh, Thomas A.
    Rau, Christoph
    CURRENT OPINION IN COLLOID & INTERFACE SCIENCE, 2012, 17 (01) : 13 - 22
  • [25] Justification and good practice in using handheld portable dental X-ray equipment: a position paper prepared by the European Academy of DentoMaxilloFacial Radiology (EADMFR)
    Berkhout, W. E. R.
    Suomalainen, A.
    Bruellmann, D.
    Jacobs, R.
    Horner, K.
    Stamatakis, H. C.
    DENTOMAXILLOFACIAL RADIOLOGY, 2015, 44 (06)
  • [26] Coherent X-Ray Diffractive Imaging
    Vartaniants, Ivan
    INTERNATIONAL CONFERENCE ON ADVANCED PHASE MEASUREMENT METHODS IN OPTICS AN IMAGING, 2010, 1236 : 200 - 200
  • [27] A compact X-ray source based on Compton scattering
    Bulyak, E
    Gladkikh, P
    Grigor'ev, Y
    Guk, I
    Karnaukhov, I
    Khodyachikh, A
    Kononenko, S
    Mocheshnikov, N
    Mytsykov, A
    Shcherbakov, A
    Tarasenko, A
    Telegin, Y
    Zelinsky, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 88 - 90
  • [28] A set of X-ray Polarimeters for the New Hard X-Ray Imaging and Polarimetric Mission
    Soffitta, Paolo
    Costa, Enrico
    Muleri, Fabio
    Campana, Riccardo
    Del Monte, Ettore
    Di Cosimo, Sergio
    Evangelista, Yuri
    Fabiani, Sergio
    Feroci, Marco
    Lazzarotto, Francesco
    Rubini, Alda
    Bellazzini, Ronaldo
    Brez, Alessandro
    Minuti, Massimo
    Omodei, Nicola
    Pinchera, Michele
    Razzano, Massimiliano
    Sgro, Carmelo
    Spandre, Gloria
    Argan, Andrea
    Matt, Giorgio
    SPACE TELESCOPES AND INSTRUMENTATION 2010: ULTRAVIOLET TO GAMMA RAY, 2010, 7732
  • [29] Effect of the amount of battery charge on tube voltage in different hand-held dental x-ray systems
    Kim, Eun-Kyung
    IMAGING SCIENCE IN DENTISTRY, 2012, 42 (01) : 1 - 4
  • [30] Periapical dental X-ray image classification using deep neural networks
    Vasdev, Dipit
    Gupta, Vedika
    Shubham, Shubham
    Chaudhary, Ankit
    Jain, Nikita
    Salimi, Mehdi
    Ahmadian, Ali
    ANNALS OF OPERATIONS RESEARCH, 2023, 326 (SUPPL 1) : 161 - 161