A tri-level optimization model to mitigate coordinated attacks on electric power systems in a cyber-physical environment

被引:102
作者
Lai, Kexing [1 ]
Illindala, Mahesh [1 ]
Subramaniam, Karthikeyan [1 ]
机构
[1] Ohio State Univ, Dept Elect & Comp Engn, Columbus, OH 43210 USA
关键词
Coordinated attack; cyber-physical system; Power system defending; Power system relay; Robust programming; Tri-level optimization; 2-STAGE ROBUST OPTIMIZATION; UNCERTAINTY; GENERATION;
D O I
10.1016/j.apenergy.2018.10.077
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The electric power system is facing greater threats each year due to malicious attacks. In the recent decade, multiple attacks on both physical and cyber layers of the power system resulted in significant economic loss. In particular, a cyber-physical coordinated attack is deemed to be a destructive behavior that is likely to cause cascading failures. Therefore, this paper focuses on hedging against a coordinated cyber-physical attack from the standpoint of allocating defending resources. The coordinated attack involves physical short-circuiting of transmission lines after intruding the communication network of protection relays. The paper proposes a tri-level optimization model to formulate the coordinated attack scenario and identify the optimal defending strategy, which is a first of its kind study of defending resource allocation to hedge against the coordinated attack. Upper level problem represents the actions of the planner and determines the optimal defending resource allocation on transmission lines and communication network of protection relays. Defending strategy achieves the lowest expected unserved energy with coordinated attacks considering multiple representative operating conditions. Middle-level problem formulates the behaviors of the attacker, who identifies the targets and attack time to maximize unserved energy. Lower-level problem simulates the actions of operator for system redispatch aimed at minimizing unserved energy. Sensitivity analyses are conducted on IEEE 14-bus system and IEEE 57-bus system to investigate the effects of attack budget, defend budget and restoration duration on unserved energy. The results indicate greater unserved energy with higher attack budget, lower defend budget, and longer restoration duration. Moreover, significant unserved energy reduction was observed when the proposed optimization model is applied to allocate defending resource.
引用
收藏
页码:204 / 218
页数:15
相关论文
共 38 条
[1]  
[Anonymous], FPL PLANS STRENGTH R
[2]  
[Anonymous], 2018, 71 ANN C PROT RELAY
[3]  
[Anonymous], IEEE 57 BUS SYST
[4]   Bilevel programming applied to power system vulnerability analysis under multiple contingencies [J].
Arroyo, J. M. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2010, 4 (02) :178-190
[5]   Performance of Electric Power Systems Under Physical Malicious Attacks [J].
Bilis, Evangelos I. ;
Kroeger, Wolfgang ;
Nan, Cen .
IEEE SYSTEMS JOURNAL, 2013, 7 (04) :854-865
[6]   An optimization model for power grid fortification to maximize attack immunity [J].
Costa, Alberto ;
Georgiadis, Dionysios ;
Ng, Tsan Sheng ;
Sim, Melvyn .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 99 :594-602
[7]   Day ahead optimization of an electric vehicle fleet providing ancillary services in the Los Angeles Air Force Base vehicle-to-grid demonstration [J].
DeForest, Nicholas ;
MacDonald, Jason S. ;
Black, Douglas R. .
APPLIED ENERGY, 2018, 210 :987-1001
[8]   CCPA: Coordinated Cyber-Physical Attacks and Countermeasures in Smart Grid [J].
Deng, Ruilong ;
Zhuang, Peng ;
Liang, Hao .
IEEE TRANSACTIONS ON SMART GRID, 2017, 8 (05) :2420-2430
[9]   A multi-uncertainty-set based two-stage robust optimization to defender-attacker-defender model for power system protection [J].
Ding, Tao ;
Yao, Li ;
Li, Fangxing .
RELIABILITY ENGINEERING & SYSTEM SAFETY, 2018, 169 :179-186
[10]   Optimizing power system investments and resilience against attacks [J].
Fang, Yiping ;
Sansavini, Giovanni .
RELIABILITY ENGINEERING & SYSTEM SAFETY, 2017, 159 :161-173