Fully automated solid-phase microextraction-fast gas chromatography-mass spectrometry method using a new ionic liquid column for high-throughput analysis of sarcosine and N-ethylglycine in human urine and urinary sediments

被引:55
作者
Bianchi, F. [1 ]
Dugheri, S. [2 ]
Musci, M. [1 ]
Bonacchi, A. [3 ]
Salvadori, E. [3 ]
Arcangeli, G. [3 ]
Cupelli, V. [3 ]
Lanciotti, M. [4 ]
Masieri, L. [4 ]
Serni, S. [4 ]
Carini, M. [4 ]
Careri, M. [1 ]
Mangia, A. [1 ]
机构
[1] Univ Parma, Dipartimento Chim Gen & Inorgan, I-43124 Parma, Italy
[2] Univ Careggi, Azienda Osped, Lab Igiene & Tossicol Ind, I-50139 Florence, Italy
[3] Univ Florence, Dipartimento Sanita Pubbl, Lab Igiene & Tossicol Ind, I-50139 Florence, Italy
[4] Univ Florence, Dipartimento Urol, SOD Urol 1, I-50139 Florence, Italy
关键词
Solid-phase microextraction; Ionic liquid column; Fast GC; Sarcosine; Prostate cancer; PROSTATE-CANCER DETECTION; RECTAL EXAMINATION FAILS; GC-MS ANALYSIS; AMINO-ACIDS; IDENTIFICATION; MARKER; MORTALITY; DIAGNOSIS;
D O I
10.1016/j.aca.2011.09.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fully automated, non invasive, rapid and high-throughput method for the direct determination of sarcosine and N-ethylglycine in urine and urinary sediments using hexyl chloroformate derivatization followed by direct immersion solid-phase micro extraction and fast gas chromatography-mass spectrometric analysis was developed and validated. The use of a new ionic liquid narrow bore column, as well as the automation and miniaturization of the preparation procedure by a customized configuration of the utilized XYZ robotic system, allowed a friendly use of the GC apparatus achieving a quantitation limit of 0.06 mu g L-1 for sarcosine, good repeatability with CV always lower than 7% and reduced analysis times useful for point-of-care testing. The method was then applied for the analysis of 56 samples of urine and urinary sediments in healthy subjects, in those with benign prostatic hypertrophy and in patients with clinically localized prostate cancer. The results obtained showed that the medians of sarcosine/creatinine in urine were 103,137 and 267 mu g g(-1) respectively, thus assessing the potential use of sarcosine as urinary biomarker for prostate cancer detection. The highest values of sensitivity (79%) and specificity (87%) were obtained in correspondence of a cut-off value of 179 mu g sarcosine (g creatinine)(-1), thus by using this cut-off threshold, sarcosine was significantly associated with the presence of cancer (p < 0.0001). Finally, ROC analyses proved that the discrimination between clinically localized prostate cancer and patients without evidence of tumor is significantly correlated with sarcosine. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:197 / 203
页数:7
相关论文
共 39 条
[1]   Mortality Results from a Randomized Prostate-Cancer Screening Trial [J].
Andriole, Gerald L. ;
Grubb, Robert L., III ;
Buys, Saundra S. ;
Chia, David ;
Church, Timothy R. ;
Fouad, Mona N. ;
Gelmann, Edward P. ;
Kvale, Paul A. ;
Reding, Douglas J. ;
Weissfeld, Joel L. ;
Yokochi, Lance A. ;
Crawford, E. David ;
O'Brien, Barbara ;
Clapp, Jonathan D. ;
Rathmell, Joshua M. ;
Riley, Thomas L. ;
Hayes, Richard B. ;
Kramer, Barnett S. ;
Izmirlian, Grant ;
Miller, Anthony B. ;
Pinsky, Paul F. ;
Prorok, Philip C. ;
Gohagan, John K. ;
Berg, Christine D. .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 360 (13) :1310-1319
[2]   Improved procedure for n-hexyl chloroformate-mediated derivatization of highly hydrophilic substances directly in water:hydroxyaminic compounds [J].
Angelino, S ;
Maurino, V ;
Minero, C ;
Pelizzetti, E ;
Vincenti, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 793 (02) :307-316
[3]   Statistics review 9: One-way analysis of variance [J].
Bewick, V ;
Cheek, L ;
Ball, J .
CRITICAL CARE, 2004, 8 (02) :130-136
[4]   Innovative sol-gel coatings for solid-phase microextraction - Development of fibers for the determination of polycyclic aromatic hydrocarbons at trace level in water [J].
Bianchi, Federica ;
Bisceglie, Franco ;
Careri, Maria ;
Di Berardino, Sara ;
Mangia, Alessandro ;
Musci, Marilena .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1196 :15-22
[5]   Optimization of the solid phase microextraction procedure for the ultra-trace determination of organotin compounds by gas chromatography-inductively coupled plasma-mass spectrometry [J].
Bianchi, Federica ;
Careri, Maria ;
Maffini, Monica ;
Mangia, Alessandro ;
Mucchino, Claudio .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (09) :970-973
[6]   An SPME-GC-MS method using an octadecyl silica fibre for the determination of the potential angiogenesis modulators 17β-estradiol and 2-methoxyestradiol in culture media [J].
Bianchi, Federica ;
Mattarozzi, Monica ;
Careri, Maria ;
Mangia, Alessandro ;
Musci, Marilena ;
Grasselli, Francesca ;
Bussolati, Simona ;
Basini, Giuseppina .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (07) :2639-2645
[7]  
Box G.E., 1978, STAT EXPT
[8]   Characterization of phosphonium ionic liquids through a linear solvation energy relationship and their use as GLC stationary phases [J].
Breitbach, Zachary S. ;
Armstrong, Daniel W. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (06) :1605-1617
[9]   Efforts to resolve the contradictions in early diagnosis of prostate cancer: a comparison of different algorithms of sarcosine in urine [J].
Cao, D-L ;
Ye, D-W ;
Zhu, Y. ;
Zhang, H-L ;
Wang, Y-X ;
Yao, X-D .
PROSTATE CANCER AND PROSTATIC DISEASES, 2011, 14 (02) :166-172
[10]  
Carlson R., 1992, DESIGN OPTIMIZATION