Case study of the upgrade of an existing office building for low energy consumption and low carbon emissions

被引:54
作者
Charles, Alexandra [1 ]
Maref, Wahid [1 ]
Ouellet-Plamondon, Claudiane M. [1 ]
机构
[1] Univ Quebec, Montreal ETS Montreal, Ecole Technol Super, 1100 Notre Dame West, Montreal, PQ H3C 1K3, Canada
关键词
MULTIOBJECTIVE OPTIMIZATION; EFFICIENCY; RETROFIT; STRATEGIES; DESIGN; IMPACT; SIMULATION; SYSTEMS; SINGLE;
D O I
10.1016/j.enbuild.2018.10.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This case study evaluates the best energy efficiency measures of an existing two-story office building from the late 1960s located in Vancouver. Natural gas was used for heating and electricity was used for lighting, cooling and other needs. The building was simulated to match both metered data and bills. The energy model allowed identifying the parameters to reduce the energy consumption and mitigate the impact on CO2-eq emissions. On-site renewable energy supply was simulated. The return on investment (ROI) of the retrofit strategies (building envelope and renewable energy) was calculated to determine the profitability. From the parametric study, the insulation of the wall and roof, the airtightness and window replacement have the most impact on energy saving and allowed reducing 45% of the total annual energy consumed. These improvements can save more than 70 tons of CO2-eq per year from reducing the natural gas consumption. The return on investment of upgrading the building envelope was 7.7 years in Vancouver. Net zero energy building performance was possible with the addition of photovoltaic solar panel and solar heating to supply the total energy needs of the building, with an ROI of 11.6 years. If we changed the building location to Montreal, the same optimized building envelope reduces the energy consumption by 39%, and the energy saving increases to 56% when using the electric heating system usually already in place. Overall, building envelope upgrades are solutions to consider to improve energy saving in northern climate. Crown Copyright (C) 2018 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:151 / 160
页数:10
相关论文
共 49 条
[1]  
[Anonymous], 2017, NAT INV REP 1990 201
[2]   IEA ESC annex 57 'evaluation of embodied energy and CO2eq for building construction' [J].
Birgisdottir, H. ;
Moncaster, A. ;
Wiberg, A. Houlihan ;
Chae, C. ;
Yokoyama, K. ;
Balouktsi, M. ;
Seo, S. ;
Oka, T. ;
Luetzkendorf, T. ;
Malmqvist, T. .
ENERGY AND BUILDINGS, 2017, 154 :72-80
[3]   Life cycle assessment (LCA) and life cycle energy analysis (LCEA) of buildings and the building sector: A review [J].
Cabeza, Luisa F. ;
Rincon, Lidia ;
Vilarino, Virginia ;
Perez, Gabriel ;
Castell, Albert .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 29 :394-416
[4]   Development of a new multi-stage building energy model calibration methodology and validation in a public library [J].
Cacabelos, Anton ;
Eguia, Pablo ;
Febrero, Lara ;
Granada, Enrique .
ENERGY AND BUILDINGS, 2017, 146 :182-199
[5]   Value impacts of energy efficiency retrofits on commercial office buildings in Toronto, Canada [J].
Carlson, Kaitlin ;
Pressnail, Kim D. .
ENERGY AND BUILDINGS, 2018, 162 :154-162
[6]   Assessment of Retrofitting Measures for a Large Historic Research Facility Using a Building Energy Simulation Model [J].
Chae, Young Tae ;
Lee, Young M. ;
Longinott, David .
ENERGIES, 2016, 9 (06)
[7]   Effectiveness of single and multiple energy retrofit measures on the energy consumption of office buildings [J].
Chidiac, S. E. ;
Catania, E. J. C. ;
Morofsky, E. ;
Foo, S. .
ENERGY, 2011, 36 (08) :5037-5052
[8]   A review of methods to match building energy simulation models to measured data [J].
Coakley, Daniel ;
Raftery, Paul ;
Keane, Marcus .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 37 :123-141
[9]   Teardown Index: Impact of property values on carbon dioxide emissions of single family housing in Vancouver [J].
Dahmen, Joseph ;
von Bergmann, Jens ;
Das, Misha .
ENERGY AND BUILDINGS, 2018, 170 :95-106
[10]  
Dettling J., 2012, QUANTIFYING VALUE BU, P174