Ultrahigh-resolution and 3-dimensional optical coherence tomography ex vivo imaging of the large and small intestines

被引:41
作者
Hsiung, PL
Pantanowitz, L
Aguirre, AD
Chen, Y
Phatak, D
Ko, TH
Bourquin, S
Schnitt, SJ
Raza, S
Connolly, JL
Mashimo, H
Fujimoto, JG
机构
[1] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[2] MIT, Elect Res Lab, Cambridge, MA 02139 USA
[3] Baystate Med Ctr, Dept Pathol, Springfield, MA 01199 USA
[4] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Dept Pathol, Boston, MA 02115 USA
[5] VA Boston Healthcare Syst, Boston, MA USA
关键词
D O I
10.1016/j.gie.2005.05.006
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Ultrahigh-resolution optical coherence tomography (OCT) has an axial resolution of < 5 mu m, 2 to 3 times finer than standard OCT This study investigates ultrahigh-resolution and three-dimensional OCT for ex vivo imaging of the large and small intestines and correlates images with histology. Methods: Ultrahigh-resolution OCT imaging was performed on fresh surgical specimens from the large and small intestines in the pathology laboratory, and images were correlated with histology. OCT was performed at 1.3-mu m wavelength with 4.5-mu m axial x 11-mu m transverse resolution and at 1.1-mu m wavelength with 3.5-mu m axial x 6-mu m transverse resolution. Three-dimensional OCT also was investigated. Results: Normal and pathologic areas from 23 surgical specimens of the large and small intestines were imaged. Ultrahigh-resolution OCT distinguished the epithelia] layer of the mucosa and visualized individual villi, glands, and crypts. Finer transverse resolutions improved visualization of features, e.g., the epithelium, but reduced the depth of field. Architectural distortion of glands from inflammatory and neoplastic processes was observed. Three-dimensional rendering enabled visualization of surface pit pattern and mucosal folds as well as subsurface crypt microstructure. Conclusions: This study evaluates new OCT technology and can provide a baseline for interpreting future ultrahigh-resolution endoscopic OCT studies.
引用
收藏
页码:561 / 574
页数:14
相关论文
共 59 条
[1]   High-resolution optical coherence microscopy for high-speed, in vivo cellular imaging [J].
Aguirre, AD ;
Hsiung, P ;
Ko, TH ;
Hartl, I ;
Fujimoto, JG .
OPTICS LETTERS, 2003, 28 (21) :2064-2066
[2]   Compact, broad-bandwidth fiber laser for sub-2-μm axial resolution optical coherence tomography in the 1300-nm wavelength region [J].
Bizheva, K ;
Povazay, B ;
Hermann, B ;
Sattmann, H ;
Drexler, W ;
Mei, M ;
Holzwarth, R ;
Hoelzenbein, T ;
Wacheck, V ;
Pehamberger, H .
OPTICS LETTERS, 2003, 28 (09) :707-709
[3]   Forward-imaging instruments for optical coherence tomography [J].
Boppart, SA ;
Bouma, BE ;
Pitris, C ;
Tearney, GJ ;
Fujimoto, JG ;
Brezinski, ME .
OPTICS LETTERS, 1997, 22 (21) :1618-1620
[4]   Self-phase-modulated Kerr-lens mode-locked Cr:forsterite laser source for optical coherence tomography [J].
Bouma, BE ;
Tearney, GJ ;
Bilinsky, IP ;
Golubovic, B ;
Fujimoto, JG .
OPTICS LETTERS, 1996, 21 (22) :1839-1841
[5]   Power-efficient nonreciprocal interferometer and linear-scanning fiber-optic catheter for optical coherence tomography [J].
Bouma, BE ;
Tearney, GJ .
OPTICS LETTERS, 1999, 24 (08) :531-533
[6]   High-resolution imaging of the human esophagus and stomach in vivo using optical coherence tomography [J].
Bouma, BE ;
Tearney, GJ ;
Compton, CC ;
Nishioka, NS .
GASTROINTESTINAL ENDOSCOPY, 2000, 51 (04) :467-474
[7]   Ultrahigh resolution real time OCT imaging using a compact femtosecond Nd:Glass laser and nonlinear fiber [J].
Bourquin, S ;
Aguirre, AD ;
Hartl, I ;
Hsiung, P ;
Ko, TH ;
Fujimoto, JG ;
Birks, TA ;
Wadsworth, WJ ;
Bünting, U ;
Kopf, D .
OPTICS EXPRESS, 2003, 11 (24) :3290-3297
[8]   Optical coherence tomography in the gastrointestinal tract [J].
Brand, S ;
Poneros, JM ;
Bouma, BE ;
Tearney, GJ ;
Compton, CC ;
Nishioka, NS .
ENDOSCOPY, 2000, 32 (10) :796-803
[9]   Optical coherence tomography for optical biopsy - Properties and demonstration of vascular pathology [J].
Brezinski, ME ;
Tearney, GJ ;
Bouma, BE ;
Izatt, JA ;
Hee, MR ;
Swanson, EA ;
Southern, JF ;
Fujimoto, JG .
CIRCULATION, 1996, 93 (06) :1206-1213
[10]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189