摘要
A dual wetting-film extraction/back-extraction system based on a multi-syringe flow injection analysis (MSFIA) set-up coupled to additional burettes and solenoid valves is proposed. The system performs on-line analyte extraction from an aqueous medium to an organic solvent based on the differential flow velocities of the aqueous and organic phases into PTFE tubing, which is due to the formation of a thin and pseudo-stationary organic film adhered to the inner walls of the extraction coil. The pre-concentrated analytes are eluted into a small eluting solution segment and conducted to a diode-array spectrophotometer for analysis. The peak maximum spectrum is used for the simultaneous determination of different analytes by using multi-component analysis with multi-linear regression (MLR). This dual system is applied to the multi-component determination of 2, 3- and 4-nitrophenol. By using 8 mi of sample and 88 mul of 1-chloroburane in l-octanol (66/34, v/v) as organic phase, a sample throughput of 11 analyses per hour can be obtained. The detection limits for 2-, 3- and 4-nitrophenol are 0.11, 0.46 and 0.07 muM, respectively, and the relative standard deviations are less than 4%. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:103 / 116
页数:14
相关论文
共 28 条
[1]  
[Anonymous], STAND METH EX WAT WA
[2]   DESIGN OF A CONTINUOUS-FLOW 2-STEP EXTRACTION SAMPLE WORK-UP SYSTEM FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BACKSTROM, K ;
DANIELSSON, LG .
ANALYTICA CHIMICA ACTA, 1990, 232 (02) :301-315
[3]  
Becerra E, 1999, LAB ROBOTICS AUTOMAT, V11, P131, DOI 10.1002/(SICI)1098-2728(1999)11:3<131::AID-LRA2>3.0.CO
[4]  
2-9
[5]   PRECONCENTRATION AND MATRIX-ISOLATION OF HEAVY-METALS THROUGH A 2-STAGE SOLVENT-EXTRACTION IN A FLOW SYSTEM [J].
BENGTSSON, M ;
JOHANSSON, G .
ANALYTICA CHIMICA ACTA, 1984, 158 (02) :147-156
[6]   Flow techniques in water analysis [J].
Cerdà, V ;
Estela, JM ;
Forteza, R ;
Cladera, A ;
Becerra, E ;
Altimira, P ;
Sitjar, P .
TALANTA, 1999, 50 (04) :695-705
[7]   Coupling of flow injection wetting-film extraction without segmentation and phase separation to flame atomic absorption spectrometry for the determination of trace copper in water samples [J].
Chen, HW ;
Liu, JS ;
Mao, XQ .
ANALYTICA CHIMICA ACTA, 1998, 370 (2-3) :151-161
[8]   APPLICATION OF MULTICOMPONENT ANALYSIS TO THE SIMULTANEOUS RESOLUTION OF PHENOL COMPOUNDS IN MIXTURES .1. DEVELOPMENT OF THE CALCULATION METHODS AND EXPERIMENTAL METHODOLOGY [J].
CLADERA, A ;
GOMEZ, E ;
ESTELA, JM ;
CERDA, V .
ANALYTICA CHIMICA ACTA, 1992, 267 (01) :95-102
[9]   Multicomponent sequential injection analysis determination of nitro-phenols in waters by on-line liquid-liquid extraction and preconcentration [J].
Cladera, A ;
Miró, M ;
Estela, JM ;
Cerdà, V .
ANALYTICA CHIMICA ACTA, 2000, 421 (02) :155-166
[10]   SIMULTANEOUS MONITORING OF BOTH PHASES IN THE SOLVENT-EXTRACTION FLOW-INJECTION ANALYSIS OF DRAMAMINE TABLETS [J].
FOSSEY, L ;
CANTWELL, FF .
ANALYTICAL CHEMISTRY, 1983, 55 (12) :1882-1885