摘要
A piston and cylinder apparatus was designed and fabricated based on pulse-echo technique to perform ultrasound scans for both liquids and solid samples of variable heights. A short time fast Fourier transform program was used to reduce noise in the signal. This apparatus was tested with distilled water. Velocity was accurately measured, whereas values of amplitude ratio varied widely. Chicken breast muscles' density, velocity, impedance and amplitude ratio were determined. Amplitude ratio could successfully discriminate between uncut samples, cut samples, and cut samples with a bone fragment, regardless of bone fragment size from 6 mm 2 to 16 mm 2 projected area. The ratio of amplitude ratios of cut samples with bone fragment to that of cut (or uncut) samples decreased as the ratio of bone fragment projected area to transducer projected area increased. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:109 / 115
页数:7
相关论文
共 16 条
[1]   Ultrasonic determination of chicken composition [J].
Chanamai, R ;
McClements, DJ .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1999, 47 (11) :4686-4692
[2]   Foreign object and internal disorder detection in food materials using noncontact ultrasound imaging [J].
Cho, BK ;
Irudayaraj, JMK .
JOURNAL OF FOOD SCIENCE, 2003, 68 (03) :967-974
[3]   SPEED OF SOUND IN PURE WATER [J].
DELGROSS.VA ;
MADER, CW .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1972, 52 (05) :1442-&
[4]  
ENSMINGER D, 1973, LOW HIGH INTENSITY A, P200
[5]   Ultrasound detection and identification of foreign bodies in food products [J].
Hæggström, E ;
Luukkala, M .
FOOD CONTROL, 2001, 12 (01) :37-45
[6]  
JIANG Y, 2003, P 4 INT S HVAC, V1, P27
[7]  
KAY GWC, 1986, TABLES PHYS CHEM CON, P74
[8]   Evaluation of ultrasonic attenuation without invoking the diffraction correction separately [J].
Kumar, B ;
Kumar, A .
ULTRASONICS, 1996, 34 (08) :847-853
[9]   ULTRASONIC PULSE ECHO REFLECTOMETER [J].
MCCLEMENTS, DJ ;
FAIRLEY, P .
ULTRASONICS, 1991, 29 (01) :58-62
[10]  
McClements DJ, 1997, CRIT REV FOOD SCI, V37, P1, DOI 10.1080/10408399709527766