Analysis and correction of errors in DTI-based tractography due to diffusion gradient inhomogeneity

被引:27
作者
Borkowski, Karol [1 ]
Krzyzak, Artur Tadeusz [2 ]
机构
[1] AGH Univ Sci & Technol, Fac Phys & Appl Comp Sci, Al Mickiewicza 30, PL-30059 Krakow, Poland
[2] AGH Univ Sci & Technol, Fac Geol Geophys & Environm Protect, Al Mickiewicza 30, PL-30059 Krakow, Poland
关键词
DTI; Tractography; BSD-DTI; B-matrix; Diffusion gradient; FIBER TRACKING; B-MATRIX; TENSOR; NONLINEARITY; DISTORTION; IMAGES; CALIBRATION; FIELDS; BIAS;
D O I
10.1016/j.jmr.2018.08.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The DTI-based tractography, despite its restrictions, is the most widely utilized fiber tracking method in clinical practice. Its fidelity is strictly dependent on the precision and accuracy of the DTI measurement, which in turn is limited by the linearity of the diffusion sensitizing gradient. The influence of the gradient distortions on the differences between the real and measured orientation of fibers was investigated by computer simulations. In addition, the potential of the b-matrix Spatial Distribution in DTI (BSD-DTI) technique in correcting such kind of errors was demonstrated experimentally. The simulations revealed that the diffusion gradient inhomogeneity, if not corrected, leads to the erroneous indication of the fiber direction. The average and maximum deviations were about 1 degrees and 15 degrees, respectively. Remarkably, the deviation between the real and measured orientation of fibers is directionally dependent, what was confirmed in MRI measurement. The deviation errors can be effectively corrected by preceding the DTI measurement with the BSD-DTI calibration. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:5 / 11
页数:7
相关论文
共 45 条
  • [1] ANALYSIS OF THE EDDY-CURRENT INDUCED ARTIFACTS AND THE TEMPORAL COMPENSATION IN NUCLEAR-MAGNETIC-RESONANCE IMAGING
    AHN, CB
    CHO, ZH
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (01) : 47 - 52
  • [2] Analysis and generalized correction of the effect of spatial gradient field distortions in diffusion-weighted imaging
    Bammer, R
    Markl, M
    Barnett, A
    Acar, B
    Alley, MT
    Pelc, NJ
    Glover, GH
    Moseley, ME
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (03) : 560 - 569
  • [3] The effect of concomitant gradient fields on diffusion tensor imaging
    Baron, C. A.
    Lebel, R. M.
    Wilman, A. H.
    Beaulieu, C.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (04) : 1190 - 1201
  • [4] Basser PJ, 2000, MAGNET RESON MED, V44, P625, DOI 10.1002/1522-2594(200010)44:4<625::AID-MRM17>3.0.CO
  • [5] 2-O
  • [6] Basser PJ, 1996, J MAGN RESON SER B, V111, P209, DOI [10.1006/jmrb.1996.0086, 10.1016/j.jmr.2011.09.022]
  • [7] ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO
    BASSER, PJ
    MATTIELLO, J
    LEBIHAN, D
    [J]. JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03): : 247 - 254
  • [8] Characterization and propagation of uncertainty in diffusion-weighted MR imaging
    Behrens, TEJ
    Woolrich, MW
    Jenkinson, M
    Johansen-Berg, H
    Nunes, RG
    Clare, S
    Matthews, PM
    Brady, JM
    Smith, SM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) : 1077 - 1088
  • [9] BORKOWSKI K, 2016, FED CONF COMPUT SCI, P935, DOI DOI 10.15439/2016F403
  • [10] A theoretical validation of the B-matrix spatial distribution approach to diffusion tensor imaging
    Borkowski, Karol
    Klodowski, Krzysztof
    Figiel, Henryk
    Krzyzak, Artur Tadeusz
    [J]. MAGNETIC RESONANCE IMAGING, 2017, 36 : 1 - 6