Human convective boundary layer and its interaction with room ventilation flow

被引:84
作者
Licina, D. [1 ,2 ]
Melikov, A. [1 ]
Sekhar, C. [2 ]
Tham, K. W. [2 ]
机构
[1] Natl Univ Singapore, Sch Design & Environm, Singapore 117566, Singapore
[2] Tech Univ Denmark, Int Ctr Indoor Environm & Energy, DK-2800 Lyngby, Denmark
关键词
Convective boundary layer; Thermal manikin; Particle image velocimetry; Pseudocolor visualization; Ventilation flow; Airflow interaction; PERSONALIZED VENTILATION; THERMAL PLUME; AIR; EXPOSURE;
D O I
10.1111/ina.12120
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study investigates the interaction between the human convective boundary layer (CBL) and uniform airflow with different velocity and from different directions. Human body is resembled by a thermal manikin with complex body shape and surface temperature distribution as the skin temperature of an average person. Particle image velocimetry (PIV) and pseudocolor visualization (PCV) are applied to identify the flow around the manikin's body. The findings show that the direction and magnitude of the surrounding airflows considerably influence the airflow distribution around the human body. Downward flow with velocity of 0.175m/s does not influence the convective flow in the breathing zone, while flow at 0.30m/s collides with the CBL at the nose level reducing the peak velocity from 0.185 to 0.10m/s. Transverse horizontal flow disturbs the CBL at the breathing zone even at 0.175m/s. A sitting manikin exposed to airflow from below with velocity of 0.30 and 0.425m/s assisting the CBL reduces the peak velocity in the breathing zone and changes the flow pattern around the body, compared to the assisting flow of 0.175m/s or quiescent conditions. In this case, the airflow interaction is strongly affected by the presence of the chair.
引用
收藏
页码:21 / 35
页数:15
相关论文
共 30 条
[1]  
[Anonymous], 2005, Ergonomics of the thermal environment _ Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
[2]  
ASHRAE, 2013, HVAC design manual for hospitals and clinics
[3]  
ASHRAE, 2012, 552012 ASHRAE
[4]  
Baldwin PEJ, 1998, ANN OCCUP HYG, V42, P303, DOI 10.1093/annhyg/42.5.303
[5]   Dispersal of exhaled air and personal exposure in displacement ventilated rooms [J].
Bjorn, E ;
Nielsen, PV .
INDOOR AIR, 2002, 12 (03) :147-164
[6]  
Bolashikov Z., 2011, P ROOMVENT
[7]   Exposure of health care workers and occupants to coughed airborne pathogens in a double-bed hospital patient room with overhead mixing ventilation [J].
Bolashikov, Zhecho D. ;
Melikov, Arsen K. ;
Kierat, Wojciech ;
Popiolek, Zbigniew ;
Brand, Marek .
HVAC&R RESEARCH, 2012, 18 (04) :602-615
[8]  
CDC, 2003, GUID ENV INF CONTR H
[9]   NATURAL-CONVECTION AROUND HUMAN HEAD [J].
CLARK, RP ;
TOY, N .
JOURNAL OF PHYSIOLOGY-LONDON, 1975, 244 (02) :283-+
[10]   A computational and experimental investigation of the human thermal plume [J].
Craven, Brent A. ;
Settles, Gary S. .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (06) :1251-1258