TL dosimetry for quality control of CR mammography imaging systems

被引:4
作者
Gaona, E.
Nieto, J. A.
Gongora, J. A. I. D.
Arreola, M.
Enriquez, J. G. F.
机构
[1] Univ Autonoma Metropolitana Xochimilco, Mexico City 04960, DF, Mexico
[2] Univ Autonoma Metropolitana Iztapalapa, Mexico City 09340, DF, Mexico
[3] CICATA, Unidad Legaria, Inst Politecn Nacl, Mexico City 11599, DF, Mexico
[4] Univ Florida, Shands Hosp, Dept Radiol, Gainesville, FL 32610 USA
来源
RADIATION EFFECTS AND DEFECTS IN SOLIDS | 2007年 / 162卷 / 10-12期
关键词
quality imaging; TLD; CR mammography;
D O I
10.1080/10420150701482170
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The aim of this work is to estimate the average glandular dose with thermoluminescent (TL) dosimetry and comparison with quality imaging in computed radiography (CR) mammography. For a measuring dose, the Food and Drug Administration (FDA) and the American College of Radiology (ACR) use a phantom, so that dose and image quality are assessed with the same test object. The mammography is a radiological image to visualize early biological manifestations of breast cancer. Digital systems have two types of image-capturing devices, full fleld digital mammography (FFDM) and CR mammography. In Mexico, there are several CR mammography systems in clinical use, but only one system has been approved for use by the FDA. Mammography CR uses a photostimulable phosphor detector (PSP) system. Most CR plates are made of 85% BaFBr and 15% BaFI doped with europium (Eu) commonly called barium flourohalide. We carry out an exploratory survey of six CR mammography units from three different manufacturers and six dedicated X-ray mammography units with fully automatic exposure. The results show three CR mammography units (50%) have a dose greater than 3.0 mGy without demonstrating improved image quality. The differences between doses averages from TLD system and dosimeter with ionization chamber are less than 10%. TLD system is a good option for average glandular dose measurement for X-rays with a HVL (0.35-0.38 mmAl) and kVp (24-26) used in quality control procedures with ACR Mammography Accreditation Phantom.
引用
收藏
页码:759 / 763
页数:5
相关论文
共 8 条
[1]  
*ACS, 2003, CANC FACTS FIG 2003
[2]  
BUSHBERG JT, 2002, ESSENTIAL PHYS MED I, P155
[3]   Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol [J].
Dance, DR ;
Skinner, CL ;
Young, KC ;
Beckett, JR ;
Kotre, CJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11) :3225-3240
[4]  
Food and Drug Administration (FDA), 2002, MAMM QUAL STAND ACTS, P40
[5]  
GAONA E, 2002, RAYOS X MAMOGRAFIA, P121
[6]  
HAMMERSTEIN GR, 1979, RADIOLOGY, V130, P485
[7]  
Hendrick R. E, 1999, ACR MAMMOGRAPHY QUAL, P117
[8]  
PISANO ED, 2004, DIGITAL MAMMOGRAPHY, P22