Construction of effective symmetrical air-cooled system for battery thermal management

被引:207
作者
Chen, Kai [1 ]
Chen, Yiming [1 ]
She, Yiqi [1 ]
Song, Mengxuan [2 ]
Wang, Shuangfeng [1 ]
Chen, Lin [3 ]
机构
[1] South China Univ Technol, Sch Chem & Chem Engn, Key Lab Enhanced Heat Transfer & Energy Conservat, Minist Educ, Guangzhou 510640, Guangdong, Peoples R China
[2] Tongji Univ, Dept Control Sci & Engn, Shanghai 201804, Peoples R China
[3] North China Elect Power Univ, Key Lab Power Stn Energy Transfer Convers & Syst, Minist Educ, Beijing 102206, Peoples R China
基金
中国国家自然科学基金;
关键词
Air-cooled battery thermal management; Symmetrical system; Uneven cell-spacing distribution; Cooling performance improvement; LITHIUM-ION BATTERY; PHASE-CHANGE MATERIAL; STRUCTURE OPTIMIZATION; FLOW CONFIGURATION; COOLING STRATEGY; PERFORMANCE; PACK; DESIGN;
D O I
10.1016/j.applthermaleng.2019.114679
中图分类号
O414.1 [热力学];
学科分类号
摘要
In an air-cooled battery thermal-management system, inducing a large temperature difference in a battery pack is very easy because of the low specific heat of air. In this study, we develop a simple method of constructing a symmetrical air-cooled system with uneven cell-spacing distribution to improve the cooling performance. First, the influence of the battery cell number on the performance of an air-cooled system is numerically studied. The results show that the system with fewer battery cells can achieve a more uniform temperature distribution, and the energy consumption of each cell is lower. Then, different symmetrical systems are constructed based on asymmetrical systems with various inlet and outlet positions. The comparisons indicate that the symmetrical systems perform much better than the asymmetrical ones. Finally, uneven cell-spacing distribution is applied to the symmetrical systems, and the corresponding distribution expressions are derived. Compared with the asymmetrical system, we achieve at least 43% reduction in the maximum cell-temperature difference and at least 33% reduction in the energy consumption. Furthermore, the designed systems perform better than the optimized ones in the previous studies.
引用
收藏
页数:9
相关论文
共 27 条
[1]  
Bai F., 2016, ADV NEW RENEW ENERGY, V4, P358
[2]   Design of the structure of battery pack in parallel air-cooled battery thermal management system for cooling efficiency improvement [J].
Chen, Kai ;
Song, Mengxuan ;
Wei, Wei ;
Wang, Shuangfeng .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 132 :309-321
[3]   Cooling efficiency improvement of air-cooled battery thermal management system through designing the flow pattern [J].
Chen, Kai ;
Wu, Weixiong ;
Yuan, Fang ;
Chen, Lin ;
Wang, Shuangfeng .
ENERGY, 2019, 167 :781-790
[4]   Design of the cell spacings of battery pack in parallel air-cooled battery thermal management system [J].
Chen, Kai ;
Chen, Yiming ;
Li, Zeyu ;
Yuan, Fang ;
Wang, Shuangfeng .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 127 :393-401
[5]   Structure optimization of parallel air-cooled battery thermal management system with U-type flow for cooling efficiency improvement [J].
Chen, Kai ;
Song, Mengxuan ;
Wei, Wei ;
Wang, Shuangfeng .
ENERGY, 2018, 145 :603-613
[6]   Structure optimization of parallel air-cooled battery thermal management system [J].
Chen, Kai ;
Wang, Shuangfeng ;
Song, Mengxuan ;
Chen, Lin .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 111 :943-952
[7]   Experimental study on the thermal management performance of air cooling for high energy density cylindrical lithium-ion batteries [J].
Fan, Yuqian ;
Bao, Yun ;
Ling, Chen ;
Chu, Yanyan ;
Tan, Xiaojun ;
Yang, Shuting .
APPLIED THERMAL ENGINEERING, 2019, 155 :96-109
[8]  
Fang X.H., 2017, Thesis
[9]   Design of flow configuration for parallel air-cooled battery thermal management system with secondary vent [J].
Hong, Sihui ;
Zhang, Xinqiang ;
Chen, Kai ;
Wang, Shuangfeng .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 116 :1204-1212
[10]   Experimental investigation of the thermal performance of heat pipe assisted phase change material for battery thermal management system [J].
Huang, Qiqiu ;
Li, Xinxi ;
Zhang, Guoqing ;
Zhang, Jiangyun ;
He, Fengqi ;
Li, Yang .
APPLIED THERMAL ENGINEERING, 2018, 141 :1092-1100