An optimization technique for performance improvement of gap-changeable MEMS accelerometers

被引:22
作者
Mohammed, Zakriya [1 ]
Dushaq, Ghada [1 ]
Chatterjee, Aveek [2 ]
Rasras, Mahmoud [1 ]
机构
[1] Khalifa Univ Sci & Technol, Masdar Inst, Dept Elect & Comp Sci Engn, I Micro Res Ctr, Abu Dhabi 54224, U Arab Emirates
[2] MEMS GlobalFoundries, Singapore, Singapore
关键词
Accelerometer; Anti-gap spacing; Comb fingers; Capacitive sensitivity; Finger gap spacing; Spring constant; SENSITIVITY; RESONATORS;
D O I
10.1016/j.mechatronics.2017.10.011
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper demonstrates the design and optimization of single- and dual-axis capacitive accelerometers. Detailed analysis together with fabrication and characterization results are reported. The designs utilize a simplified comb structure to detect capacitance change between rotor and stator fingers. By optimizing the gap spacing (finger gap and anti-finger gap), the devices are designed to yield high capacitance change as a function of the proof mass displacement. It was found that there is a critical anti-gap spacing for a selected finger gap at which the device sensitivity is the highest (ratio of 3.45: 1). Designs are first optimized using Finite Element Analysis (FEA) tools. Initial simulation results indicated a differential capacitive sensitivity of 80fF/g and 68fF/g for single-and dual-axis accelerometers, respectively. The capacitance-voltage (CV) measurements exhibited a parabolic behavior which is an important characteristic for these type of accelerometers. Furthermore, results show a rest capacitance of 16.42 pF and sensitivity of 35 fF/g for single-axis accelerometer. Overall, the devices have excellent sensitivity, high linearity, and low cross-axis sensitivity. The accelerometers are fabricated using GlobalFoundries' Inertial Measurement Unit (IMU) platform and have a compact footprint of 1.8 mm x 1.8 mm.
引用
收藏
页码:203 / 216
页数:14
相关论文
共 37 条
[1]   Sub-micro-gravity in-plane accelerometers with reduced capacitive gaps and extra seismic mass [J].
Abdolvand, Reza ;
Amini, Babak Vakili ;
Ayazi, Farrokh .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2007, 16 (05) :1036-1043
[2]  
Alciatore DG, 2011, INSTRO MECHATRONICS
[3]   Nonlinear regression model of a low-g MEMS accelerometer [J].
Ang, Wei Tech ;
Khosla, Pradeep K. ;
Riviere, Cameron N. .
IEEE SENSORS JOURNAL, 2007, 7 (1-2) :81-88
[4]  
Aydin O, 2012, IEEE SENSORS, V2012
[5]  
Baldwin C., 2005, P IMAC 23 C EXP STRU
[6]   A ± 1-g dual-axis linear accelerometer in a standard 0.5-μm CMOS technology for high-sensitivity applications [J].
Baschirotto, A ;
Gola, A ;
Chiesa, E ;
Lasalandra, E ;
Pasolini, F ;
Tronconi, M ;
Ungaretti, T .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2003, 38 (07) :1292-1297
[7]   Optimization of MEMS capacitive accelerometer [J].
Benmessaoud, Mourad ;
Nasreddine, Mekkakia Maaza .
MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2013, 19 (05) :713-720
[8]  
Boser BE, 1997, INT C SOL STAT SENS
[9]   A monolithic three-axis micro-g micromachined silicon capacitive accelerometer [J].
Chae, J ;
Kulah, H ;
Najafi, K .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2005, 14 (02) :235-242
[10]  
Chae J., 2004, J MICROMECH MICROENG, V15, P336