Fast acceleration-encoded magnetic resonance imaging

被引:15
作者
Forster, J
Sieverding, L
Breuer, J
Lutz, O
Schick, F
机构
[1] Univ Tubingen, Abt Radiol Diagnost, D-72076 Tubingen, Germany
[2] Univ Tubingen, Abt Kinderheilkunde 2, D-72076 Tubingen, Germany
[3] Univ Tubingen, Inst Phys, D-72076 Tubingen, Germany
关键词
MR imaging; MR flow imaging; MR acceleration mapping;
D O I
10.1118/1.1333413
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Direct acceleration imaging with high spatial resolution was implemented and tested. The well-known principle of phase encoding motion components was applied. Suitable gradient switching provides a signal phase shift proportional to the acceleration perpendicular to the slice in the first scan of the sequences. An additional scan serving as a reference was recorded for compensation of phase effects due to magnetic field inhomogeneities. The first scan compensated for phase shifts from undesired first- and second-order motions; the second scan was completely insensitive to velocity and acceleration in all directions. Advantages of the proposed two-step technique compared to former approaches with Fourier acceleration encoding (with several phase encoding steps) are relatively short echo times and short total measuring times. On the other hand, the new approach does not allow us to assess the velocity or acceleration spectrum simultaneously. The capabilities of the sequences were tested on a modern 1.5 T whole body MR unit providing relatively high gradient amplitudes (25 mT/m) and short rise times (600 mus to maximum amplitude). The results from a mechanical acceleration phantom showed a standard deviation of 0.3 m/s(2) in sequences with an acceleration range between -12 and 12 m/s(2). This range covers the expected maximum acceleration in the human aorta of 10 m/s(2). Further tests were performed on a stenosis phantom with a variable volume flow rate to assess the how characteristics and possible displacement artifacts of the sequences. Preliminary examinations of volunteers demonstrate the potential applicability of the technique in vivo. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:28 / 35
页数:8
相关论文
共 19 条
[1]   MR FLOW IMAGING BY VELOCITY-COMPENSATED UNCOMPENSATED DIFFERENCE IMAGES [J].
AXEL, L ;
MORTON, D .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (01) :31-34
[2]   Concomitant gradient terms in phase contrast MR: Analysis and correction [J].
Bernstein, MA ;
Zhou, XHJ ;
Polzin, JA ;
King, KF ;
Ganin, A ;
Pelc, NJ ;
Glover, GH .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (02) :300-308
[3]   SIMULTANEOUS DETECTION OF MULTIPLE COMPONENTS OF MOTION WITH MRI [J].
DUMOULIN, CL ;
DARROW, RD ;
EISNER, DR ;
TARNAWSKI, M ;
SCOTT, KT ;
CARO, CG .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (04) :652-660
[4]   PULSATILE BLOOD VELOCITY IN HUMAN ARTERIES DISPLAYED BY MAGNETIC-RESONANCE IMAGING [J].
FEINBERG, DA ;
CROOKS, L ;
HOENNINGER, J ;
ARAKAWA, M ;
WATTS, J .
RADIOLOGY, 1984, 153 (01) :177-180
[5]   FLOW THROUGH A CONVERGING-DIVERGING TUBE AND ITS IMPLICATIONS IN OCCLUSIVE VASCULAR DISEASE .1. THEORETICAL DEVELOPMENT [J].
FORRESTE.JH ;
YOUNG, DF .
JOURNAL OF BIOMECHANICS, 1970, 3 (03) :297-&
[6]   VELOCITY-MEASUREMENTS IN FLOWING FLUIDS BY MNR [J].
GARROWAY, AN .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1974, 7 (14) :L159-L163
[7]   DETECTION OF SEA-WATER MOTION BY NUCLEAR PRECESSION [J].
HAHN, EL .
JOURNAL OF GEOPHYSICAL RESEARCH, 1960, 65 (02) :776-777
[8]   MOTION-INDUCED PHASE-SHIFTS IN MR - ACCELERATION EFFECTS IN QUANTITATIVE FLOW MEASUREMENTS - A RECONSIDERATION [J].
KOUWENHOVEN, M ;
HOFMAN, MBM ;
SPRENGER, M .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (06) :766-777
[9]  
MORAN P R, 1982, Magnetic Resonance Imaging, V1, P197
[10]  
MULLER E, 1989, P SMRM 8 ANN M, P729