Near-Atomic Resolution Structure Determination in Over-Focus with Volta Phase Plate by Cs-Corrected Cryo-EM

被引:37
|
作者
Fan, Xiao [1 ,2 ]
Zhao, Lingyun [1 ,2 ]
Liu, Chuan [1 ,2 ]
Zhang, Jin-Can [3 ,4 ]
Fan, Kelong [5 ]
Yan, Xiyun [5 ,6 ]
Peng, Hai-Lin [3 ,4 ]
Lei, Jianlin [1 ]
Wang, Hong-Wei [1 ,2 ]
机构
[1] Tsinghua Univ, Beijing Adv Innovat Ctr Struct Biol, Sch Life Sci, Minist Educ,Key Lab Prot Sci, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Tsinghua Peking Joint Ctr Life Sci, Beijing 100084, Peoples R China
[3] Peking Univ, Beijing Sci & Engn Ctr Nanocarbons, Beijing Natl Lab Mol Sci, Ctr Nanochem,Coll Chem & Mol Engn, Beijing 100871, Peoples R China
[4] Peking Univ, Acad Adv Interdisciplinary Studies, Beijing 100871, Peoples R China
[5] Chinese Acad Sci, Key Lab Prot & Peptide Pharmaceut, CAS Univ Tokyo Joint Lab Struct Virol & Immunol, Inst Biophys, Beijing 100101, Peoples R China
[6] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
北京市自然科学基金; 中国博士后科学基金;
关键词
CONTRAST CRYOELECTRON TOMOGRAPHY; TRANSMISSION ELECTRON-MICROSCOPY; BEAM-INDUCED MOTION; PROTEIN COMPLEX; H-FERRITIN; VISUALIZATION; NANOPARTICLES; MICROGRAPHS; DETECTORS; RIBOSOME;
D O I
10.1016/j.str.2017.08.008
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Volta phase plate (VPP) is a recently developed transmission electron microscope (TEM) apparatus that can significantly enhance the image contrast of biological samples in cryoelectron microscopy, and therefore provide the possibility to solve structures of relatively small macromolecules at high-resolution. In this work, we performed theoretical analysis and found that using phase plate on objective lens spherical aberration (Cs)-corrected TEM may gain some interesting optical properties, including the over-focus imaging of macromolecules. We subsequently evaluated the imaging strategy of frozen-hydrated apo-ferritin with VPP on a Cs-corrected TEM and obtained the structure of apo-ferritin at near-atomic resolution from both under-and over-focused dataset, illustrating the feasibility and new potential of combining VPP with Cs-corrected TEM for high-resolution cryo-EM.
引用
收藏
页码:1623 / +
页数:11
相关论文
共 4 条
  • [1] Volta phase plate data collection facilitates image processing and cryo-EM structure determination
    von Loeffelholz, Ottilie
    Papai, Gabor
    Danev, Radostin
    Myasnikov, Alexander G.
    Natchiar, S. Kundhavai
    Hazemann, Isabelle
    Menetret, Jean-Francois
    Klaholz, Bruno P.
    JOURNAL OF STRUCTURAL BIOLOGY, 2018, 202 (03) : 191 - 199
  • [2] Near-Atomic Resolution Structure Determination of a Cypovirus Capsid and Polymerase Complex Using Cryo-EM at 200 kV
    Li, Xiaowu
    Zhou, Niyun
    Chen, Wenyuan
    Zhu, Bin
    Wang, Xurong
    Xu, Bin
    Wang, Jiawei
    Liu, Hongrong
    Cheng, Lingpeng
    JOURNAL OF MOLECULAR BIOLOGY, 2017, 429 (01) : 79 - 87
  • [3] Single-particle cryo-EM structures from iDPC-STEM at near-atomic resolution
    Lazic, Ivan
    Wirix, Maarten
    Leidl, Max Leo
    de Haas, Felix
    Mann, Daniel
    Beckers, Maximilian
    Pechnikova, Evgeniya, V
    Muller-Caspary, Knut
    Egoavil, Ricardo
    Bosch, Eric G. T.
    Sachse, Carsten
    NATURE METHODS, 2022, 19 (09) : 1126 - 1136
  • [4] Cryo-EM near-atomic structure of a dsRNA fungal virus shows ancient structural motifs preserved in the dsRNA viral lineage
    Luque, Daniel
    Gomez-Blanco, Josue
    Garriga, Damia
    Brilot, Axel F.
    Gonzalez, Jose M.
    Havens, Wendy M.
    Carrascosa, Jose L.
    Trus, Benes L.
    Verdaguer, Nuria
    Ghabrial, Said A.
    Caston, Jose R.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2014, 111 (21) : 7641 - 7646