Implementation of Relative Humidity Control in DMA Measurements

被引:2
|
作者
Coletti, Marco [1 ]
机构
[1] TA Instruments, Vimodrone, MI, Italy
来源
5TH INTERNATIONAL CONFERENCE ON TIMES OF POLYMERS TOP AND COMPOSITES | 2010年 / 1255卷
关键词
DMA; Relative Humidity; Coefficient of Hygroscopic Expansion;
D O I
10.1063/1.3455673
中图分类号
O59 [应用物理学];
学科分类号
摘要
A novel apparatus to perform Dynamic Mechanical Analysis tests under controlled conditions of Relative Humidity and Temperature is presented. It is possible to assess material properties which are dependent on RH (such as the Coefficient of Hygroscopic Expansion) or classical DMA parameters under more real-life conditions (Storage and Loss Moduli in a wet environment). Three case studies are presented reporting about mechanical properties of Nylon 6, the Coefficient of Hygroscopic Expansion of Nylon 6 and the Stress Relaxation behavior of Nation 112, a material which is used in applications such as fuel cells.
引用
收藏
页码:82 / 84
页数:3
相关论文
共 50 条
  • [31] Constrained temperature and relative humidity predictive control: Agricultural greenhouse case of study
    Hamidane, Hafsa
    EL Faiz, Samira
    Rkik, Iliass
    El Khayat, Mohamed
    Guerbaoui, Mohammed
    Ed-Dahhak, Abdelali
    Lachhab, Abdeslam
    INFORMATION PROCESSING IN AGRICULTURE, 2024, 11 (03): : 409 - 420
  • [32] Effect of relative humidity on preeclampsia
    Choi, G. J.
    Ahn, K. H.
    Kim, L. Y.
    Hwang, S. Y.
    Hong, S. C.
    Oh, M. J.
    Kim, H. J.
    CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, 2017, 44 (02): : 264 - 267
  • [33] Metrological challenges for measurements of key climatological observables. Part 4: atmospheric relative humidity
    Lovell-Smith, J. W.
    Feistel, R.
    Harvey, A. H.
    Hellmuth, O.
    Bell, S. A.
    Heinonen, M.
    Cooper, J. R.
    METROLOGIA, 2016, 53 (01) : R40 - R59
  • [34] Modelling diurnal pattern of relative humidity from daily air temperature and relative humidity data of Hyderabad
    Srivastava, N. N.
    Rao, V. U. M.
    Saikia, U. S.
    Kumar, P. Vijaya
    Rao, A. V. M. Subba
    JOURNAL OF AGROMETEOROLOGY, 2011, 13 (01): : 25 - 30
  • [35] Design and Implementation of High Speed UART Based on DMA
    Zang, Feng
    Niu, Honghai
    PROCEEDINGS OF THE 2018 3RD INTERNATIONAL CONFERENCE ON ELECTRICAL, AUTOMATION AND MECHANICAL ENGINEERING (EAME 2018), 2018, 127 : 128 - 131
  • [36] Amplitude modulation of relative humidity by wind in Northeast China: the formation of variance annual cycle in relative humidity
    Da Nian
    Yu Huang
    Zuntao Fu
    Climate Dynamics, 2022, 59 : 1133 - 1142
  • [37] Amplitude modulation of relative humidity by wind in Northeast China: the formation of variance annual cycle in relative humidity
    Nian, Da
    Huang, Yu
    Fu, Zuntao
    CLIMATE DYNAMICS, 2022, 59 (3-4) : 1133 - 1142
  • [38] Relative humidity measurements of a thin-film humidity sensor in condensing conditions in the temperature range from-40 °C to 5 °C
    Lee, Sang-Wook
    Lee, Young-Suk
    Choi, Byung Il
    Kim, Yong-Gyoo
    Kim, Sunghun
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2024, 35 (07)
  • [39] Testing of salt-contaminated materials:: use of aqueous solutions for control of relative humidity
    Goncalves, T. Diaz
    Abreu, M. Marinho
    JOURNAL OF TESTING AND EVALUATION, 2007, 35 (05) : 529 - 532
  • [40] Study on the control effectiveness of relative humidity by various ventilation systems for the conservation of cultural relics
    Liu, Benli
    He, Chenchen
    Zhang, Guobin
    Xu, Ruihong
    Zhan, Hongtao
    Wu, Fasi
    He, Dongpeng
    HERITAGE SCIENCE, 2024, 12 (01):