Agreement Between the OptoGait and Instrumented Treadmill System for the Quantification of Spatiotemporal Treadmill Running Parameters

被引:12
|
作者
Weart, Amy N. [1 ]
Miller, Erin M. [2 ]
Freisinger, Gregory M. [3 ]
Johnson, Michael R. [1 ]
Goss, Donald L. [4 ]
机构
[1] Keller Army Community Hosp, Dept Phys Therapy, West Point, NY 10996 USA
[2] Baylor Univ, Keller Army Community Hosp, Div Sports Phys Therapy Fellowship 1, West Point, NY USA
[3] US Mil Acad, Dept Civil & Mech Engn, West Point, NY 10996 USA
[4] High Point Univ, Dept Phys Therapy, High Point, NC USA
来源
FRONTIERS IN SPORTS AND ACTIVE LIVING | 2020年 / 2卷
关键词
gait analysis; running; spatiotemporal parameters; OptoGait; method comparision; PHOTOELECTRIC-CELL SYSTEM; GAIT; LENGTH; REPEATABILITY; RELIABILITY; VALIDITY; ANTERIOR; CONTACT; RUNNERS; CADENCE;
D O I
10.3389/fspor.2020.571385
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The measurement of spatiotemporal gait parameters is commonly utilized to assess gait in healthy and injured individuals. The OptoGait system is a portable system and can be mounted to a treadmill to collect data in a clinical, training, or research setting. The purpose of this method comparison study was to examine the agreement of spatiotemporal gait parameters calculated by the OptoGait compared to an instrumented treadmill system during running. Thirty healthy runners ran on an instrumented treadmill with the OptoGait 1-m system mounted along the treadmill platform. Spatiotemporal running variables of step rate, step length, and contact time were calculated during the final minute of treadmill running. The level of agreement between the OptoGait and treadmill was analyzed using intraclass correlation coefficients [ICC (2,3)] for step rate, step length, and contact time. Step rate and step length demonstrated excellent agreement. Contact time demonstrated good agreement. Intraclass correlation coefficients for spatiotemporal parameters ranged from 0.83 to 0.99. The OptoGait demonstrated good to excellent agreement in the evaluation of running step rate, step length, and contact time and should be considered for use in clinical, training, or research settings.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] RUNNING PERFORMANCE, PACE STRATEGY, AND THERMOREGULATION DIFFER BETWEEN A TREADMILL AND INDOOR TRACK
    Heesch, Matthew W. S.
    Slivka, Dustin R.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2015, 29 (02) : 330 - 335
  • [42] Spatiotemporal Parameters are not Substantially Influenced by Load Carriage or Inclination During Treadmill and Overground Walking
    Fellin, Rebecca E.
    Seay, Joseph F.
    Gregorczyk, Karen N.
    Hasselquist, Leif
    JOURNAL OF HUMAN KINETICS, 2016, 50 (01) : 27 - 35
  • [43] Absolute reliability and validity of the OptoGaitTM system to measure spatiotemporal gait parameters during running
    Garcia-Pinillos, Felipe
    Latorre-Roman, Pedro A.
    Chicano-Gutierrez, Jose M.
    Ruiz-Malagon, Emilio J.
    Parraga-Montilla, Juan A.
    Roche-Seruendo, Luis E.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2022, 236 (02) : 90 - 96
  • [44] Comparison between Accelerometer and Gyroscope in Predicting Level-Ground Running Kinematics by Treadmill Running Kinematics Using a Single Wearable Sensor
    Chow, Daniel Hung Kay
    Tremblay, Luc
    Lam, Chor Yin
    Yeung, Adrian Wai Yin
    Cheng, Wilson Ho Wu
    Tse, Peter Tin Wah
    SENSORS, 2021, 21 (14)
  • [45] Agreement between Optoelectronic System and Wearable Sensors for the Evaluation of Gait Spatiotemporal Parameters in Progressive Supranuclear Palsy
    Ricciardi, Carlo
    Pisani, Noemi
    Donisi, Leandro
    Abate, Filomena
    Amboni, Marianna
    Barone, Paolo
    Picillo, Marina
    Cesarelli, Mario
    Amato, Francesco
    SENSORS, 2023, 23 (24)
  • [46] Evaluation of osteoarthritis induced by treadmill-running exercise using the modified Mankin and the new OARSI assessment system
    Lee, Yun Jong
    Park, Ji Ah
    Yang, Sei Hoon
    Kim, Kwang Yong
    Kim, Byoung Kwon
    Lee, Eun Young
    Lee, Eun Bong
    Seo, Jeong-Wook
    Echtermeyer, Frank
    Pap, Thomas
    Song, Yeong Wook
    RHEUMATOLOGY INTERNATIONAL, 2011, 31 (12) : 1571 - 1576
  • [47] Lower between-limb asymmetry during running on treadmill compared to overground in subjects with laterally pronounced knee osteoarthritis
    Robadey, Jacques
    Staudenmann, Didier
    Schween, Raphael
    Gehring, Dominic
    Gollhofer, Albert
    Taube, Wolfgang
    PLOS ONE, 2018, 13 (10):
  • [48] Heart rates at equivalent submaximal levels of VO2 do not differ between deep water running and treadmill running
    Mercer, JA
    Jensen, RL
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 1998, 12 (03) : 161 - 165
  • [49] Development of a force-sensing cane instrumented within a treadmill-based virtual reality locomotor system
    Perez, Claire
    Oates, Alison
    Hughey, Lucinda
    Fung, Joyce
    2009 VIRTUAL REHABILITATION INTERNATIONAL CONFERENCE, 2009, : 154 - +
  • [50] Does Arch Stiffness Influence Running Spatiotemporal Parameters? An Analysis of the Relationship between Influencing Factors on Running Performance
    Garcia-Pinillos, Felipe
    Jaen-Carrillo, Diego
    Latorre-Roman, Pedro angel
    Escalona-Marfil, Carles
    Soto-Hermoso, Victor M.
    Lago-Fuentes, Carlos
    Pueyo-Villa, Silvia
    Dominguez-Azpiroz, Irma
    Roche-Seruendo, Luis E.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (05) : 1 - 10