Agreement Between the OptoGait and Instrumented Treadmill System for the Quantification of Spatiotemporal Treadmill Running Parameters

被引:12
|
作者
Weart, Amy N. [1 ]
Miller, Erin M. [2 ]
Freisinger, Gregory M. [3 ]
Johnson, Michael R. [1 ]
Goss, Donald L. [4 ]
机构
[1] Keller Army Community Hosp, Dept Phys Therapy, West Point, NY 10996 USA
[2] Baylor Univ, Keller Army Community Hosp, Div Sports Phys Therapy Fellowship 1, West Point, NY USA
[3] US Mil Acad, Dept Civil & Mech Engn, West Point, NY 10996 USA
[4] High Point Univ, Dept Phys Therapy, High Point, NC USA
来源
FRONTIERS IN SPORTS AND ACTIVE LIVING | 2020年 / 2卷
关键词
gait analysis; running; spatiotemporal parameters; OptoGait; method comparision; PHOTOELECTRIC-CELL SYSTEM; GAIT; LENGTH; REPEATABILITY; RELIABILITY; VALIDITY; ANTERIOR; CONTACT; RUNNERS; CADENCE;
D O I
10.3389/fspor.2020.571385
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The measurement of spatiotemporal gait parameters is commonly utilized to assess gait in healthy and injured individuals. The OptoGait system is a portable system and can be mounted to a treadmill to collect data in a clinical, training, or research setting. The purpose of this method comparison study was to examine the agreement of spatiotemporal gait parameters calculated by the OptoGait compared to an instrumented treadmill system during running. Thirty healthy runners ran on an instrumented treadmill with the OptoGait 1-m system mounted along the treadmill platform. Spatiotemporal running variables of step rate, step length, and contact time were calculated during the final minute of treadmill running. The level of agreement between the OptoGait and treadmill was analyzed using intraclass correlation coefficients [ICC (2,3)] for step rate, step length, and contact time. Step rate and step length demonstrated excellent agreement. Contact time demonstrated good agreement. Intraclass correlation coefficients for spatiotemporal parameters ranged from 0.83 to 0.99. The OptoGait demonstrated good to excellent agreement in the evaluation of running step rate, step length, and contact time and should be considered for use in clinical, training, or research settings.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Validity and reliability of a portable gait analysis system for measuring spatiotemporal gait characteristics: comparison to an instrumented treadmill
    Lars Donath
    Oliver Faude
    Eric Lichtenstein
    Corina Nüesch
    Annegret Mündermann
    Journal of NeuroEngineering and Rehabilitation, 13
  • [22] Determining the centre of pressure during walking and running using an instrumented treadmill
    Verkerke, GJ
    Hof, AL
    Zijlstra, W
    Ament, W
    Rakhorst, G
    JOURNAL OF BIOMECHANICS, 2005, 38 (09) : 1881 - 1885
  • [23] Reproducibility of electromyographic and dynamic parameters during running on a treadmill with deliberate changes in running technique
    Karamanidis, K
    Arampatzis, A
    Brüggemann, GP
    DEUTSCHE ZEITSCHRIFT FUR SPORTMEDIZIN, 2002, 53 (04): : 107 - 113
  • [24] Reliability and minimum detectable change of measures of gait in children during walking and running on an instrumented treadmill
    McSweeney, Simon C.
    Reed, Lloyd F.
    Wearing, Scott C.
    GAIT & POSTURE, 2020, 75 : 105 - 108
  • [25] Agreement Between Spatiotemporal Gait Parameters Measured by a Markerless Motion Capture System and Two Reference Systems-a Treadmill-Based Photoelectric Cell and High-Speed Video Analyses: Comparative Study
    Garcia-Pinillos, Felipe
    Jaen-Carrillo, Diego
    Hermoso, Victor Soto
    Roman, Pedro Latorre
    Delgado, Pedro
    Martinez, Cristian
    Carton, Antonio
    Roche Seruendo, Luis
    JMIR MHEALTH AND UHEALTH, 2020, 8 (10):
  • [26] The effect of visual focus on spatio-temporal and kinematic parameters of treadmill running
    Lucas-Cuevas, Angel G.
    Priego Quesada, Jose I.
    Gooding, Josh
    Lewis, Martin G. C.
    Encarnacion-Martinez, Alberto
    Perez-Soriano, Pedro
    GAIT & POSTURE, 2018, 59 : 292 - 297
  • [27] Validity and Reliability of an Instrumented Treadmill with an Accelerometry System for Assessment of Spatio-Temporal Parameters and Impact Transmission
    Encarnacion-Martinez, Alberto
    Perez-Soriano, Pedro
    Sanchis-Sanchis, Roberto
    Garcia-Gallart, Antonio
    Berenguer-Vidal, Rafael
    SENSORS, 2021, 21 (05) : 1 - 17
  • [28] Differences between Systems Using Optical and Capacitive Sensors in Treadmill-Based Spatiotemporal Analysis of Level and Sloping Gait
    Mandalidis, Dimitris
    Kafetzakis, Ioannis
    SENSORS, 2022, 22 (07)
  • [29] SPATIOTEMPORAL COMPARISON OF OVERGROUND AN D TREADMILL RUNNING WITH PRESSURE SENSOR INSOLES IN DIVISION I COLLEGIATE RUNNERS
    Tao, Hanz
    Joyce, Lindsay
    Kozak, Bethany
    Luiken, Jacob
    Wendt, Nathan
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2019, 14 (05): : 731 - 739
  • [30] Shock attenuation, spatio-temporal and physiological parameter comparisons between land treadmill and water treadmill running
    Paul W.Macdermid
    Philip W.Fink
    Stephen R.Stannard
    Journal of Sport and Health Science, 2017, 6 (04) : 482 - 488