Three-level hysteresis current control strategy for three-phase four-switch shunt active filters

被引:40
|
作者
Biricik, Samet [1 ,2 ]
Komurcugil, Hasan [3 ]
机构
[1] European Univ Lefke, Dept Elect & Elect Engn, Via Mersin 10, Lefka, Turkey
[2] Dublin Inst Technol, Sch Elect & Elect Engn, Dublin, Ireland
[3] Eastern Mediterranean Univ, Dept Comp Engn, Via Mersin 10, Gazimagusa, Turkey
关键词
active filters; electric current control; reliability; harmonic distortion; power harmonic filters; three-level hysteresis current control strategy; three-level HCC strategy; three-phase four-switch shunt active power filters; four-switch topology; series-connected capacitors; cost reduction; switching loss; system reliability improvement; capacitor voltages; reduced switching frequency; steady-state performance; dynamic performance; RT-LAB real-time platform; total harmonic distortion; source current; IEEE-519; standard; POWER FILTER; REACTIVE POWER; RECTIFIER; DESIGN; IMPLEMENTATION; COMPENSATION;
D O I
10.1049/iet-pel.2015.0764
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this study, a three-level hysteresis current-control (HCC) strategy is proposed for three-phase four-switch shunt active power filters. The four-switch topology which utilises four switching devices together with two series connected capacitors is able to reduce the cost, switching losses and improve the reliability of system. In this topology, when the current control of phases A and B is achieved successfully, the current control of phase C which is connected to the midpoint of the series connected capacitors is achieved automatically. The current control is achieved by using a three-level HCC strategy. An important consequence of using this control strategy is that it enables access to the zero level of the input voltage of active filter so that a switching device is only switched when the current error is negative, while it remains off when the current error is positive. Furthermore, the imbalance in the capacitor voltages is eliminated by adding a feedback term (the difference in the capacitor voltages multiplied by a suitable gain) to the current control. The proposed control strategy offers a reduced switching frequency, losses and cost. The steady-state and dynamic performance of the proposed control strategy is verified through simulations and experimental studies.
引用
收藏
页码:1732 / 1740
页数:9
相关论文
共 50 条
  • [41] Current Regulated PWM Based Control for Four-Switch Three-Phase Brushless DC Motor Drives
    Varatharaju, V. M.
    Mathur, B. L.
    Udhayakumar, K.
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2011, 6 (04): : 1620 - 1626
  • [42] Overmodulation Strategy for Four-Switch Three-Phase Inverter Based on Virtual Voltage Vector
    Li, Ze
    Zhang, Ming
    Guo, Yuanbo
    Zhang, Xiaohua
    PROCEEDINGS OF THE 36TH CHINESE CONTROL CONFERENCE (CCC 2017), 2017, : 7364 - 7369
  • [43] Three-phase four-switch PFC and its analytical model
    Klima, Jiri
    Skramlik, Jiri
    Valouch, Viktor
    POWERENG2007: INTERNATIONAL CONFERENCE ON POWER ENGINEERING - ENERGY AND ELECTRICAL DRIVES PROCEEDINGS, VOLS 1 & 2, 2007, : 66 - +
  • [44] Scalar PWM algorithms for four-switch three-phase inverters
    An, Q. T.
    Sun, L.
    Zhao, K.
    Jahns, T. M.
    ELECTRONICS LETTERS, 2010, 46 (13) : 900 - U48
  • [45] A Ten-Switch Three-Phase Three-Level Inverter
    Deng, Xiaojun
    Wang, Hongliang
    Zhu, Xiaonan
    Zhang, Wenyuan
    Wang, Hanzhe
    Yue, Xiumei
    2020 IEEE 9TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC2020-ECCE ASIA), 2020, : 279 - 283
  • [46] Harmonic Current Compensation based on Three-phase Three-level Shunt Active Filter using Fuzzy Logic Current Controller
    Salim, Chennai
    Benchouia, M-T
    Golea, A.
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2011, 6 (05) : 595 - 604
  • [47] Space vector pulse-width modulation algorithm and DC-side voltage control strategy of three-phase four-switch active power filters
    Wang, Wen
    Luo, An
    Xu, Xianyong
    Fang, Lu
    Thuyen Minh Chau
    Li, Zhou
    IET POWER ELECTRONICS, 2013, 6 (01) : 125 - 135
  • [48] A novel variable hysteresis band current control of three-phase three-level rectifier with constant switching frequency
    Maswood, AI
    Liu, FR
    2005 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS, 1-3, 2005, : 23 - 27
  • [49] Parallel control of three-phase three-wire shunt active power filters
    Wei, Xueliang
    Dai, Ke
    Fang, Xin
    Geng, Pan
    Luo, Fang
    Kang, Yong
    IPEMC 2006: CES/IEEE 5TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2006, : 790 - +
  • [50] A Four-Switch Three-Phase SEPIC-Based Inverter
    Diab, Mohamed S.
    Elserougi, Ahmed
    Massoud, Ahmed M.
    Abdel-Khalik, Ayman S.
    Ahmed, Shehab
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (09) : 4891 - 4905