Three-level hysteresis current control strategy for three-phase four-switch shunt active filters

被引:40
|
作者
Biricik, Samet [1 ,2 ]
Komurcugil, Hasan [3 ]
机构
[1] European Univ Lefke, Dept Elect & Elect Engn, Via Mersin 10, Lefka, Turkey
[2] Dublin Inst Technol, Sch Elect & Elect Engn, Dublin, Ireland
[3] Eastern Mediterranean Univ, Dept Comp Engn, Via Mersin 10, Gazimagusa, Turkey
关键词
active filters; electric current control; reliability; harmonic distortion; power harmonic filters; three-level hysteresis current control strategy; three-level HCC strategy; three-phase four-switch shunt active power filters; four-switch topology; series-connected capacitors; cost reduction; switching loss; system reliability improvement; capacitor voltages; reduced switching frequency; steady-state performance; dynamic performance; RT-LAB real-time platform; total harmonic distortion; source current; IEEE-519; standard; POWER FILTER; REACTIVE POWER; RECTIFIER; DESIGN; IMPLEMENTATION; COMPENSATION;
D O I
10.1049/iet-pel.2015.0764
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this study, a three-level hysteresis current-control (HCC) strategy is proposed for three-phase four-switch shunt active power filters. The four-switch topology which utilises four switching devices together with two series connected capacitors is able to reduce the cost, switching losses and improve the reliability of system. In this topology, when the current control of phases A and B is achieved successfully, the current control of phase C which is connected to the midpoint of the series connected capacitors is achieved automatically. The current control is achieved by using a three-level HCC strategy. An important consequence of using this control strategy is that it enables access to the zero level of the input voltage of active filter so that a switching device is only switched when the current error is negative, while it remains off when the current error is positive. Furthermore, the imbalance in the capacitor voltages is eliminated by adding a feedback term (the difference in the capacitor voltages multiplied by a suitable gain) to the current control. The proposed control strategy offers a reduced switching frequency, losses and cost. The steady-state and dynamic performance of the proposed control strategy is verified through simulations and experimental studies.
引用
收藏
页码:1732 / 1740
页数:9
相关论文
共 50 条
  • [21] Shunt active filter based on three-level inverter for three-phase four-wire systems
    Vodyakho, O.
    Kim, T.
    IET POWER ELECTRONICS, 2009, 2 (03) : 216 - 226
  • [22] Control and topologies for three-phase three-level active power
    Jin, TT
    Wen, J
    Smedley, K
    IPEMC 2004: THE 4TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2004, : 450 - 455
  • [23] Three-Phase Three-Level Inverter Based Shunt Active Power Filter
    Altin, Necmi
    Kaplan, Orhan
    Ozdemir, Saban
    2014 16TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE AND EXPOSITION (PEMC), 2014, : 799 - 804
  • [24] Eight-switch CHB-based three-level three-phase shunt active power filter
    Muneer, V.
    Bhattacharya, Avik
    IET POWER ELECTRONICS, 2020, 13 (16) : 3511 - 3521
  • [25] A Control Strategy for a Three-Phase Four-Wire Shunt Active Filter
    Ferreira, Filipe
    Monteiro, Luis
    Afonso, Joao L.
    Couto, Carlos
    IECON 2008: 34TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-5, PROCEEDINGS, 2008, : 360 - 365
  • [26] Reply to comments on: 'General SVPWM strategy for three different four-switch three-phase inverters'
    Liu, Y. -C.
    ELECTRONICS LETTERS, 2018, 54 (07)
  • [27] A reduced hysteresis controller for a four-switch three-phase bidirectional power electronics interface
    Lo, YK
    Chiu, HJ
    Li, WT
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1999, 46 (04) : 864 - 866
  • [28] LQ control of a three-phase four-wire shunt active power filter based on three-level NPC inverter
    Kedjar, Bachir
    Al-Haddad, Kamal
    2008 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-4, 2008, : 1236 - 1241
  • [29] A Current Control Scheme of Brushless DC Motors Driven by Four-Switch Three-Phase Inverters
    Xia, Changliang
    Wu, Dan
    Shi, Tingna
    Wei, Chen
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2017, 5 (01) : 547 - 558
  • [30] Modulation and Control Strategy of Three-Phase Three-Level Four-Leg NPC Inverter
    Chen, Haohui
    Zhang, Zhi
    Li, Yiyun
    Ren, Bin
    2022 34TH CHINESE CONTROL AND DECISION CONFERENCE, CCDC, 2022, : 1071 - 1076