A surface crosslinked UHMWPE stabilized by vitamin E with low wear and high fatigue strength

被引:64
作者
Oral, Ebru [1 ,2 ]
Ghali, Bassem W. [1 ]
Rowell, Shannon L. [1 ]
Micheli, Brad R. [1 ]
Lozynsky, Andrew J. [1 ]
Muratoglu, Orhun K. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Orthopaed Surg, Harris Orthopaed Biomech & Biomat Lab, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Cambridge, MA 02138 USA
关键词
Vitamin E; Arthroplasty; Delamination; Interface; Biomaterial; Implant; MOLECULAR-WEIGHT POLYETHYLENE; ALPHA-TOCOPHEROL; PROPAGATION RESISTANCE; ACETABULAR COMPONENTS; MECHANICAL-PROPERTIES; LINKING; IRRADIATION; OXIDATION; RADIATION; DAMAGE;
D O I
10.1016/j.biomaterials.2010.05.041
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wear particle-induced periprosthetic osteolysis has been a clinical problem driving the development of wear resistant ultrahigh molecular weight polyethylene (UHMWPE) for total joint replacement. Radiation crosslinking has been used to decrease wear through decreased plastic deformation; but crosslinking also reduces mechanical properties including fatigue resistance, a major factor limiting the longevity of joint implants. Reducing UHMWPE wear with minimal detriment to mechanical properties is an unaddressed need for articular bearing surface development. Here we report a novel approach to achieve this by limiting crosslinking to the articular surface. The antioxidant vitamin E reduces crosslinking efficiency in UHMWPE during irradiation with increasing concentration, thus we propose to spatially control the crosslink density distribution by controlling the vitamin E concentration profile. Surface crosslinking UHMWPE prepared using this approach had high wear resistance and decreased crosslinking in the bulk resulting in high fatigue crack propagation resistance. The interface region did not represent a weakness in the material due to the gradual change in the crosslink density. Such an implant has the potential of decreasing risk of fatigue fracture of total joint implants as well as expanding the use of UHMWPE to younger and more active patients. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:7051 / 7060
页数:10
相关论文
共 42 条
[1]  
*ASTM INT, 2008, F221402 ASTM INT
[2]   The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene [J].
Baker, DA ;
Bellare, A ;
Pruitt, L .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 66A (01) :146-154
[3]   Stabilisation of ultra-high molecular weight polyethylene with Vitamin E [J].
Bracco, P. ;
Brunella, V. ;
Zanetti, M. ;
Luda, M. P. ;
Costa, L. .
POLYMER DEGRADATION AND STABILITY, 2007, 92 (12) :2155-2162
[4]   A new pin-on-disk wear testing method for simulating wear of polyethylene on cobalt-chrome alloy in total hip arthroplasty [J].
Bragdon, CR ;
O'Connor, DO ;
Lowenstein, JD ;
Jasty, M ;
Biggs, SA ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2001, 16 (05) :658-665
[5]  
BRUNNER L, 2008, AMST NL T 8 WORLD BI
[6]   A Double-Blind, Prospective, Randomized Controlled Trial Comparing Highly Cross-Linked and Conventional Polyethylene in Primary Total Hip Arthroplasty [J].
Calvert, George T. ;
Devane, Peter A. ;
Fielden, Jan ;
Adams, Kathryn ;
Horne, J. Geoffrey .
JOURNAL OF ARTHROPLASTY, 2009, 24 (04) :505-510
[7]  
CHRISTENSEN S, 2006, CHIC IL T 52 ANN M O
[8]  
Coates J., ENCY ANAL CHEM APPL
[9]  
COSTA L, 2009, LAS VEG NV T 55 ANN
[10]   Evaluation of oxidation and fatigue damage of retrieved crossfire polyethylene acetabular cups [J].
Currier, Barbara H. ;
Currier, John H. ;
Mayor, Michael B. ;
Lyford, Kimberly A. ;
Collier, John P. ;
Van Citters, Douglas W. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (09) :2023-2029