Development and validation of sensitive methods for simultaneous determination of 9 antiviral drugs in different various environmental matrices by UPLC-MS/MS

被引:24
|
作者
Yao, Li [1 ]
Dou, Wen-Yuan [1 ]
Ma, Yan-Fang [1 ]
Liu, You-Sheng [2 ,3 ]
机构
[1] Guangdong Acad Sci, Inst Anal, China Natl Analyt Ctr, Guangzhou 510070, Peoples R China
[2] South China Normal Univ, Sch Environm, SCNU Environm Res Inst, Guangdong Prov Key Lab Chem Pollut & Environm Saf, Guangzhou 510006, Peoples R China
[3] South China Normal Univ, Sch Environm, MOE Key Lab Environm Theoret Chem, Guangzhou 510006, Peoples R China
关键词
Antiviral drugs; Multi-residue determination; Tandem solid-phase extraction; QuEChERS; Environmental matrix; SOLID-PHASE EXTRACTION; WASTE-WATER TREATMENT; NAIROBI RIVER-BASIN; LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; ANTIRETROVIRAL DRUGS; GAS-CHROMATOGRAPHY; SURFACE-WATER; OREOCHROMIS-MOSSAMBICUS; PESTICIDE-RESIDUES;
D O I
10.1016/j.chemosphere.2021.131047
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Trace antiviral drug contamination in aquatic ecosystems is becoming a significant environmental concern that requires an urgent efficient determination method. Here we developed sensitive and robust multi-residue determination methods to simultaneously extract and analyze 9 commonly used antiviral drugs (abacavir, zidovudine, efavirenz, nevirapine, ritonavir, lopinavir, lamivudine, telbivudine and entecavir) in surface water, wastewater, sediment, and sludge. Water samples were extracted with solid-phase extraction (SPE) technique using tandem hydrophilic-lipophilic balance and graphitized carbon black cartridges, while sediment and sludge samples were extracted using QuEChERS (quick, easy, cheap, effective, rugged, and safe) method. The extraction conditions of SPE (pH and cartridge type) and QuEChERS (acetic acid content, salts reagent, and purification sorbent) methods were carefully optimized. We observed that under optimum conditions, the method quantification limits of the 9 antiviral drugs in water and solid samples ranged from 0.05 to 19.23 ng L-1 and from 0.02 to 7.38 ng g-1, respectively. For environmental samples spiking 3 different concentrations, the recovery values for the most targeted antiviral drugs ranged from 70 to 130%, except for efavirenz. All targeted antiviral drugs were detected in wastewater samples except for entecavir. We also found abacavir, efavirenz, ritonavir, lopinavir, and telbivudine in sediment and sludge samples. Notably, telbivudine was identified in all environmental matrices, with a high concentration of 127 ng L-1 and 222 ng g-1 in water and sediment samples, respectively.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Development and validation of a sensitive UPLC-MS/MS method for the simultaneous determination of dapoxetine and its two metabolites in human plasma
    Zhang, Wei-min
    Wu, Qiang
    Wang, Ying-fei
    Sun, Ming
    Wang, Rong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 119 : 45 - 49
  • [2] Development and validation of a UPLC-MS/MS method for the simultaneous determination of paritaprevir and ritonavir in rat liver
    Ocque, Andrew J.
    Hagler, Colleen E.
    Difrancesco, Robin
    Woolwine-Cunningham, Yvonne
    Bednasz, Cindy J.
    Morse, Gene D.
    Talal, Andrew H.
    BIOANALYSIS, 2016, 8 (13) : 1353 - 1363
  • [3] Development and validation of a highly sensitive UPLC-MS/MS method for the determination of Huperzine A in rat plasma
    Zhang, Kejun
    Wang, Haizhou
    BIOMEDICAL CHROMATOGRAPHY, 2024, 38 (11)
  • [4] Simultaneous determination of 11 illicit drugs and metabolites in wastewater by UPLC-MS/MS
    Yuan, Shuai
    Wang, Xin
    Wang, Roujia
    Luo, Ruxin
    Shi, Yan
    Shen, Baohua
    Liu, Wei
    Yu, Zhiguo
    Xiang, Ping
    WATER SCIENCE AND TECHNOLOGY, 2020, 82 (09) : 1771 - 1780
  • [5] Development and validation of UPLC-MS/MS method for simultaneous determination of gestodene and ethinyl estradiol in rat plasma
    Xiong, Zhili
    Sun, Xiaohong
    Huo, Taoguang
    Li, Ning
    Zheng, Yan
    Sun, Yi
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (02) : 160 - 168
  • [6] Development and Validation of a UPLC-MS/MS Method for the Simultaneous Determination of Telmisartan and Metformine HCl in Human Plasma
    Fawzy, Sherif
    Helal, Mohamed A.
    Abdel-Aziz, Lobna M.
    Salama, Ismail
    CURRENT ANALYTICAL CHEMISTRY, 2015, 11 (02) : 130 - 137
  • [7] Development and validation of a systematic UPLC-MS/MS method for simultaneous determination of three phenol impurities in ritonavir
    Venugopal, N.
    Reddy, A. Vijaya Bhaskar
    Madhavi, G.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 90 : 127 - 133
  • [8] Development and validation of a UPLC-MS/MS method for simultaneous determination of LBPT and its metabolites in human plasma
    Wu, Mengyi
    Liu, Aijing
    Zhuang, Quankun
    Jia, Ranran
    Zhou, Yinping
    Liu, Yali
    Wang, Hongyun
    BIOANALYSIS, 2020, 12 (04) : 211 - 220
  • [9] Simultaneous determination of 14 antiviral drugs and relevant metabolites in chicken muscle by UPLC-MS/MS after QuEChERS preparation
    Mu, Pengqian
    Xu, Nana
    Chai, Tingting
    Jia, Qi
    Yin, Zhiqiang
    Yang, Shuming
    Qian, Yongzhong
    Qiu, Jing
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1023 : 17 - 23
  • [10] Development and validation of a rapid and sensitive UPLC-MS/MS method for determination of uracil and dihydrouracil in human plasma
    Jacobs, Bart A. W.
    Rosing, Hilde
    de Vries, Niels
    Meulendijks, Didier
    Henricks, Linda M.
    Schellens, Jan H. M.
    Beijnen, Jos H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 126 : 75 - 82