Novel Approach to Test the Relative Recovery of Liquid-Phase Standard in Sorbent-Tube Analysis of Gaseous Volatile Organic Compounds

被引:48
作者
Kim, Yong-Hyun [1 ]
Kim, Ki-Hyun [1 ]
机构
[1] Sejong Univ, Environm & Energy Dept, Seoul 143747, South Korea
基金
新加坡国家研究基金会;
关键词
GAS-CHROMATOGRAPHY; THERMAL-DESORPTION; SAMPLING METHODS; ADSORBENT TUBE; AMBIENT AIR; PERFORMANCE; POLLUTANTS; EXPOSURE; QUALITY;
D O I
10.1021/ac300334b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sorbent tubes (STs) are highly efficient and versatile tools for collecting gaseous samples of volatile organic compounds (VOCs). In order to assess the experimental bias in their application, the relative recovery (RR) of 19 VOCs (acetaldehyde, propionaldehyde, butyraldehyde, isovaleraldehyde, valeraldehyde, benzene, toluene, m-xylene, p-xylene, o-xylene, styrene, methyl ethyl ketone, methyl isobutyl ketone, isobutyl alcohol, butyl acetate, propionic acid, butyric acid, isovaleric acid, and n-valeric acid) was evaluated in accordance to three different sorbent tube types: (1) Tenax (Te), (2) Carbopack X (X), and (3) Tenax + Carbopack B + Carboxen 1000 (TBC). Calibration was initially made by direct injection of the liquid working standard (L-WS) into the link tube (LT) of the thermal desorption (TD) system. The LT was modified to optimize the transfer of all the VOCs to the focusing trap of the TD. Three different types of ST were then loaded with the same L-WS using (1) direct injection (DI) to tube and (2) injection to tube via vaporization (VAP). The results of the two ST/TD methods (DI and VAP) were normalized to those of the LT/TD to derive RR The mean RR values of all target VOCs were 62.6 (X), 83.9 (Te), and 82.8% (TBC) for the DI and 76.5, 75.8, and 81.0% for the VAP. Although the results using TBC and Te tubes exhibited better recovery in DI than in VAP, those of X tubes had the reverse trend. As such, the relative affinity of each sorbent material can be affected by the mode of introduction of the standard. The practicality of the LT/TD, especially as a reference for the ST/TD, was also validated from some environmental samples in an ancillary experiment. As such, we were able to demonstrate the usefulness of the LT/TD method to evaluate analyte recovery from spiked sorbent tubes.
引用
收藏
页码:4126 / 4139
页数:14
相关论文
共 19 条
  • [1] [Anonymous], 1999, COMPENDIUM METHODS D
  • [2] Environmental pollutants and skin cancer
    Baudouin, C
    Charveron, M
    Tarroux, R
    Gall, Y
    [J]. CELL BIOLOGY AND TOXICOLOGY, 2002, 18 (05) : 341 - 348
  • [3] COLLECTION AND ANALYSIS OF TRACE ORGANIC VAPOR POLLUTANTS IN AMBIENT ATMOSPHERES - PERFORMANCE OF A TENAX-GC ADSORBENT TUBE
    BROWN, RH
    PURNELL, CJ
    [J]. JOURNAL OF CHROMATOGRAPHY, 1979, 178 (01): : 79 - 90
  • [4] Quality control in quantification of volatile organic compounds analysed by thermal desorption-gas chromatography-mass spectrometry
    Demeestere, Kristof
    Dewulf, Jo
    De Roo, Karlien
    De Wispelaere, Patrick
    Van Langenhove, Herman
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1186 (1-2) : 348 - 357
  • [5] COLLECTING AND ANALYZING SYSTEM FOR THE DETERMINATION OF ORGANIC TRACE SUBSTANCES IN THE ATMOSPHERE
    FIGGE, K
    DOMMROSE, AM
    RABEL, W
    ZERHAU, W
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 327 (3-4): : 279 - 292
  • [6] Comparative study of the adsorption performance of a multi-sorbent bed (Carbotrap, Carbopack X, Carboxen 569) and a Tenax TA adsorbent tube for the analysis of volatile organic compounds (VOCs)
    Gallego, E.
    Roca, F. J.
    Perales, J. F.
    Guardino, X.
    [J]. TALANTA, 2010, 81 (03) : 916 - 924
  • [7] Effect of standard phase differences between gas and liquid and the resulting experimental bias in the analysis of gaseous volatile organic compounds
    Kim, Yong-Hyun
    Kim, Ki-Hyun
    [J]. ANALYTICA CHIMICA ACTA, 2012, 714 : 98 - 103
  • [8] Matney ML, 2000, AM IND HYG ASSOC J, V61, P69, DOI 10.1202/0002-8894(2000)061<0069:MTFCVO>2.0.CO
  • [9] 2
  • [10] Gas chromatographic approach for the determination of carbonyl compounds in ambient air
    Pal, Raktim
    Kim, Ki-Hyun
    [J]. MICROCHEMICAL JOURNAL, 2008, 90 (02) : 147 - 158