Non-invasive evaluation of portal hypertension using shearwave elastography: analysis of two algorithms combining liver and spleen stiffness in 191 patients with cirrhosis

被引:43
|
作者
Elkrief, L. [1 ,2 ]
Ronot, M. [2 ,3 ,4 ]
Andrade, F. [2 ]
Burgio, M. Dioguardi [3 ,4 ]
Issoufaly, T. [2 ]
Zappa, M. [3 ,4 ]
Roux, O. [2 ]
Bissonnette, J. [2 ]
Payance, A. [2 ]
Lebrec, D. [2 ,4 ]
Francoz, C. [2 ,4 ]
Soubrane, O. [4 ,5 ]
Valla, D. [2 ,4 ]
Durand, F. [2 ,4 ]
Vilgrain, V. [3 ,4 ]
Castera, L. [2 ,4 ]
Rautou, P-E [2 ,6 ]
机构
[1] Hop Univ Geneve, Serv Hepatol & Gastroenterol, Suisse, Switzerland
[2] Hop Beaujon, AP HP, Serv Hepatol, Clichy, France
[3] Hop Beaujon, AP HP, Serv Radiol, Clichy, France
[4] Univ Paris Diderot Paris 7, INSERM, CRI, UMR 1149, Paris, France
[5] Hop Beaujon, AP HP, Serv Chirurg Digest, Clichy, France
[6] Univ Paris 05, Sorbonne Paris Cite, INSERM, Paris Cardiovasc Res Ctr,UMR 970, Paris, France
关键词
BAVENO VI CRITERIA; HEPATITIS-C VIRUS; WAVE ELASTOGRAPHY; COMPENSATED CIRRHOSIS; TRANSIENT ELASTOGRAPHY; CONSENSUS WORKSHOP; DISEASE; VARICES; RISK; DIAGNOSIS;
D O I
10.1111/apt.14488
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Two algorithms based on sequential measurements of liver and spleen stiffness using two-dimensional shearwave elastography (2D-SWE) have been recently proposed to estimate clinically significant portal hypertension (hepatic venous pressure gradient [HVPG] >10 mm Hg) in patients with cirrhosis, with excellent diagnostic accuracy. Aim: To validate externally these algorithms in a large cohort of patients with cirrhosis. Methods: One hundred and ninety-one patients with stable cirrhosis (Child-Pugh class A 39%, B 29% and C 31%) who underwent liver and spleen stiffness measurements using 2D-SWE at the time of HVPG measurement were included. Diagnostic accuracy of the 2 algorithms was assessed by calculating sensitivity, specificity, positive and negative predictive values. Results: The first algorithm, using liver stiffness <16.0 kilopascals (kPa) and then spleen stiffness <26.6 kPa, was used to rule-out HVPG >10 mm Hg. In our population, its sensitivity and negative predictive value were 95% and 63% respectively. The second algorithm, using liver stiffness >38.0 kPa, or liver stiffness <= 38.0 kPa but spleen stiffness >27.9 kPa, was used to rule-in HVPG >= 10 mm Hg. In our population, its specificity and positive predictive value were 52% and 83% respectively. Restricting the analyses to the 74 patients without any history of decompensation of cirrhosis or to the 65 patients with highly reliable liver stiffness measurement did not improve the results. Conclusion: In our population, diagnostic accuracies of non-invasive algorithms based on sequential measurements of liver and spleen stiffness using 2D-SWE were acceptable, but not good enough to replace HVPG measurement or to base clinical decisions.
引用
收藏
页码:621 / 630
页数:10
相关论文
共 50 条
  • [1] Non-invasive evaluation of clinically significant portal hypertension: validation of two novel algorithms combining liver and spleen stiffness using shear-wave elastography in a large independent cohort of patients with cirrhosis
    Elkrief, L.
    Rautou, P-E
    Ronot, M.
    Zappa, M.
    Burgio, M. Di.
    Roux, O.
    Bissonnette, J.
    Payance, A.
    Lebrec, D.
    Francoz, C.
    Soubrane, O.
    Valla, D.
    Durand, F.
    Vilgrain, V.
    Castera, L.
    JOURNAL OF HEPATOLOGY, 2017, 66 (01) : S663 - S663
  • [2] Non-invasive evaluation of portal hypertension using ultrasound elastography
    Berzigotti, Annalisa
    JOURNAL OF HEPATOLOGY, 2017, 67 (02) : 399 - 411
  • [3] Non-invasive diagnosis of portal hypertension in cirrhosis using ultrasound based elastography
    Grgurevic, Ivica
    Bokun, Tomislav
    Bozin, Tonci
    Matic, Vladimir
    Haberle, Sara
    Sporea, Ioan
    MEDICAL ULTRASONOGRAPHY, 2017, 19 (03) : 310 - 317
  • [4] Is spleen stiffness the newfrontier for non-invasive assessment of portal hypertension?
    Giuffre, Mauro
    Macor, Daniele
    Masutti, Flora
    Tine, Fabio
    Abazia, Cristiana
    Patti, Riccardo
    Buonocore, Matteo Rossano
    Colombo, Anna
    Visintin, Alessia
    Campigotto, Michele
    Monica, Fabio
    Croce, Saveria Lory
    JOURNAL OF HEPATOLOGY, 2019, 70 (01) : E644 - E644
  • [5] Non-invasive diagnostic and prognostic evaluation of liver cirrhosis and portal hypertension
    Berzigotti, Annalisa
    Ashkenazi, Eyal
    Reverter, Enric
    Abraldes, Juan G.
    Bosch, Jaime
    DISEASE MARKERS, 2011, 31 (03) : 129 - 138
  • [6] SPLEEN AND LIVER ELASTOGRAPHY AS A NON-INVASIVE TOOL FOR DETECTION OF ESOPHAGEAL VARICES IN PATIENTS WITH LIVER CIRRHOSIS
    Macor, D.
    Giuffre, M.
    Tine, F.
    Masutti, F.
    Abazia, C.
    Buonocore, M. R.
    Colombo, A.
    Visintin, A.
    Campigotto, M.
    Monica, F.
    Croce, S. L.
    DIGESTIVE AND LIVER DISEASE, 2019, 51 : E172 - E172
  • [7] The Value of Liver and Spleen Stiffness for Evaluation of Portal Hypertension in Compensated Cirrhosis
    Reiberger, Thomas
    HEPATOLOGY COMMUNICATIONS, 2022, 6 (05) : 950 - 964
  • [8] Portal Hypertension in Patients with Liver Cirrhosis: Diagnostic Accuracy of Spleen Stiffness
    Takuma, Yoshitaka
    Nouso, Kazuhiro
    Morimoto, Youichi
    Tomokuni, Junko
    Sahara, Akiko
    Takabatake, Hiroyuki
    Matsueda, Kazuhiro
    Yamamoto, Hiroshi
    RADIOLOGY, 2016, 279 (02) : 609 - 619
  • [9] Osteopontin is a new non-invasive parameter of portal hypertension in patients with liver cirrhosis
    Bruha, Radan
    Jachymova, Marie
    Petrtyl, Jaromir
    Vitek, Libor
    Urbanek, Petr
    Dvorak, Karel
    HEPATOLOGY, 2014, 60 : 1192A - 1192A
  • [10] OSTEOPONTIN IS A NEW NON-INVASIVE PARAMETER OF PORTAL HYPERTENSION IN PATIENTS WITH LIVER CIRRHOSIS
    Bruha, R.
    Jachymova, M.
    Petrtyl, J.
    Vitek, L.
    Urbanek, P.
    Dvorak, K.
    JOURNAL OF HEPATOLOGY, 2014, 60 (01) : S234 - S234