Bioabsorbable versus titanium interference screws with hamstring autograft in anterior cruciate ligament reconstruction: A prospective randomized trial with 2-year follow-up

被引:56
作者
Myers, Peter [1 ]
Logan, Martin [1 ]
Stokes, Andy [1 ]
Boyd, Kevin [1 ]
Watts, Mark [1 ,2 ]
机构
[1] Brisbane Private Hosp, Brisbane Orthopaed & Sports Med Ctr, Brisbane, Qld 4000, Australia
[2] Queensland Univ Technol, Inst Hlth & Biomed Innovat, Brisbane, Qld, Australia
关键词
anterior cruciate ligament; interference screws; hamstring autograft; bioabsorbable;
D O I
10.1016/j.arthro.2008.02.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to prospectively assess the outcome of hamstring autograft anterior cruciate ligament (ACL) reconstruction by use of identically shaped bioabsorbable and titanium interference screws in a randomized trial. Methods: One hundred patients were randomized to have either bioabsorbable or titanium interference screws used for graft tunnel fixation in hamstring autograft ACL reconstruction. Patients were objectively and subjectively assessed preoperatively and 3, 6, 12, and 24 months postoperatively. Radiographs at 12 months postoperatively were also assessed for tunnel width. Results: There were no differences in clinical outcome by use of Lysholm and International Knee Documentation Committee scores between the 2 groups at any stage of follow-up to 2 years. Tibial tunnel widths were the same between the 2 groups. There was slightly more tunnel widening in the femur when bioabsorbable interference screws were used. Conclusions: Identically shaped bioabsorbable interference screws and titanium interference screws used for hamstring autograft ACL reconstruction are equally successful up to 2 years postoperatively. Level of Evidence: Level 1, prospective randomized trial with more than 80% follow-up.
引用
收藏
页码:817 / 823
页数:7
相关论文
共 18 条
[1]   Anterior cruciate ligament reconstruction with bioabsorbable polyglycolic acid interference screws:: MR imaging follow-up [J].
Bach, FD ;
Carlier, RY ;
Elis, JB ;
Mompoint, DM ;
Feydy, A ;
Judet, O ;
Beaufils, P ;
Vallée, C .
RADIOLOGY, 2002, 225 (02) :541-550
[2]   FOREIGN-BODY REACTIONS TO FRACTURE FIXATION IMPLANTS OF BIODEGRADABLE SYNTHETIC-POLYMERS [J].
BOSTMAN, O ;
HIRVENSALO, E ;
MAKINEN, J ;
ROKKANEN, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (04) :592-596
[3]   Soft-tissue interference fixation: Bioabsorbable screw versus metal screw [J].
Brand, JC ;
Nyland, J ;
Caborn, DNM ;
Johnson, DL .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (08) :911-916
[4]   Endoscopic reconstruction of the anterior cruciate ligament using bone-patellar tendon-bone grafts fixed with bioabsorbable or metal interference screws - A prospective randomized study of the clinical outcome [J].
Drogset, JO ;
Grontvedt, T ;
Tegnander, A .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (08) :1160-1165
[5]   SEVERE ASEPTIC SYNOVITIS OF THE KNEE AFTER BIODEGRADABLE INTERNAL-FIXATION - A CASE-REPORT [J].
FRIDEN, T ;
RYDHOLM, U .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (01) :94-97
[6]   A prospective randomized comparison of bioabsorbable and titanium anterior cruciate ligament interference screws [J].
Kaeding, C ;
Farr, J ;
Kavanaugh, T ;
Pedroza, A .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (02) :147-151
[7]   Bone tunnel remodeling at the site of biodegradable interference screws used for anterior cruciate ligament reconstruction:: 5-year follow-up [J].
Lajtai, G ;
Schmiedhuber, G ;
Unger, F ;
Aitzetmüller, G ;
Klein, M ;
Noszian, I ;
Orthner, E .
ARTHROSCOPY, 2001, 17 (06) :597-602
[8]   Is bone tunnel osseointegration in hamstring tendon autograft anterior cruciate ligament reconstruction important? [J].
Logan, M ;
Williams, A ;
Myers, P .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (08)
[9]   A 10-year comparison of anterior cruciate ligament reconstructions with hamstring tendon and patellar tendon autograft - A controlled, prospective trial [J].
Pinczewski, Leo A. ;
Lyman, Jeffrey ;
Salmon, Lucy J. ;
Russell, Vivianne J. ;
Roe, Justin ;
Linklater, James .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2007, 35 (04) :564-574
[10]   The natural history of a bioabsorbable interference screw used for anterior cruciate ligament reconstruction with a 4-strand hamstring technique [J].
Radford, MJ ;
Noakes, J ;
Read, J ;
Wood, DG .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (06) :707-710