An assessment of the accuracy of renal blood flow estimation by Doppler ultrasound

被引:52
作者
Wan, Li [1 ]
Yang, Natalie [2 ]
Hiew, Chee-Yan [2 ]
Schelleman, Anthony [2 ]
Johnson, Lynne [2 ]
May, Clive [3 ]
Bellomo, Rinaldo [1 ]
机构
[1] Austin Hosp, Dept Intens Care, Heidelberg, Vic 3084, Australia
[2] Austin Hosp, Dept Radiol, Heidelberg, Vic 3084, Australia
[3] Univ Melbourne, Howard Florey Inst, Melbourne, Vic, Australia
关键词
Doppler ultrasound; renal blood flow; transit-time flow probes; renal artery; peak velocity; mean velocity; resistive index; receiver operating characteristics curve; limits of agreement; bias; correlation;
D O I
10.1007/s00134-008-1106-8
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Knowledge of renal blood flow is considered important in the management of critically ill patients with acute renal failure. Renal Doppler ultrasound has been used to estimate renal blood flow. Its accuracy, however, has not been formally assessed. Design: Prospective blinded animal study. Setting: University physiology laboratory. Subjects: Seven merino crossewes. Interventions: We chronically implanted transit-time flow probes around the left renal artery and performed Doppler ultrasound measurements of RBF. We simultaneously recorded RBF values obtained with implanted flow probes and Doppler ultrasound during (a) observation, (b) dobutamine and (c) nitroprusside infusion in random order. Results: In a total of 202 paired measurements, Doppler ultrasound measured peak systolic velocity (PSV) correlated very weakly with implanted flow probe measurements of RBF (r(2) = 0.015), as did end-diastolic velocity (EDV; r(2) = 0.086) and mean velocity (MV_vel; r(2) = 0.04). We also found similar weak correlations with other Doppler-ultrasound-derived indices. All comparisons showed bias and wide limits of agreement. Conclusions: Doppler-ultrasound-derived estimates of RBF show little correlation with transit-time flow probe measurements, display significant bias and wide limits of agreement and have low accuracy for clinically significant changes in RBF in large animals.
引用
收藏
页码:1503 / 1510
页数:8
相关论文
共 22 条
[1]  
AVASTHI PS, 1984, J ULTRAS MED, V3, P213
[2]   Renal blood flow measurements with use of phase-contrast magnetic resonance imaging: Normal values and reproducibility [J].
Bax, L ;
Bakker, CJG ;
Klein, WM ;
Blanken, N ;
Beutler, JJ ;
Mali, WPTRM .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 16 (06) :807-814
[3]   EVALUATION OF A TRANSIT-TIME SYSTEM FOR THE CHRONIC MEASUREMENT OF BLOOD-FLOW IN CONSCIOUS SHEEP [J].
BEDNARIK, JA ;
MAY, CN .
JOURNAL OF APPLIED PHYSIOLOGY, 1995, 78 (02) :524-530
[4]   STATISTICS NOTES .12. CALCULATING CORRELATION-COEFFICIENTS WITH REPEATED OBSERVATIONS .1. CORRELATION WITHIN-SUBJECTS [J].
BLAND, JM ;
ALTMAN, DG .
BRITISH MEDICAL JOURNAL, 1995, 310 (6977) :446-446
[5]   CALCULATING CORRELATION-COEFFICIENTS WITH REPEATED OBSERVATIONS .2. CORRELATION BETWEEN SUBJECTS [J].
BLAND, JM ;
ALTMAN, DG .
BRITISH MEDICAL JOURNAL, 1995, 310 (6980) :633-633
[6]  
BURNS PN, 1985, RADIOL CLIN N AM, V23, P641
[7]   Validation study of a new transit time ultrasonic flow probe for continuous great vessel measurements [J].
Dean, DA ;
Jia, CX ;
Cabreriza, SE ;
DAlessandro, DA ;
Dickstein, ML ;
Sardo, MJ ;
Chalik, N ;
Spotnitz, HM .
ASAIO JOURNAL, 1996, 42 (05) :M671-M676
[8]   Vital organ blood flow during hyperdynamic sepsis [J].
Di Giantomasso, D ;
May, CN ;
Bellomo, R .
CHEST, 2003, 124 (03) :1053-1059
[9]   Vascular and nonvascular complications of renal transplants: Sonographic evaluation and correlation with other imaging modalities, surgery, and pathology [J].
Friedewald, SM ;
Molmenti, EP ;
Friedewald, JJ ;
DeJong, MR ;
Hamper, UM .
JOURNAL OF CLINICAL ULTRASOUND, 2005, 33 (03) :127-139
[10]   MODIFIED DOPPLER FLOWMETRY IN THE SPLANCHNIC CIRCULATION [J].
GIBSON, RN ;
GIBSON, PR ;
DONLAN, JD ;
PADMANABHAN, R .
GASTROENTEROLOGY, 1993, 105 (04) :1029-1034