Sensors based on ruthenium-doped TiO2 nanoparticles loaded into multi-walled carbon nanotubes for the detection of flufenamic acid and mefenamic acid

被引:147
作者
Shetti, Nagaraj P. [1 ,2 ,4 ]
Nayak, Deepti S. [1 ,2 ]
Malode, Shweta J. [1 ,2 ]
Kakarla, Raghava Reddy [3 ]
Shukla, Shyam S. [4 ]
Aminabhavi, Tejraj M. [4 ]
机构
[1] KLE Inst Technol, Dept Chem, Electrochem & Mat Grp, Gokul 580030, Hubballi, India
[2] Visvesvaraya Technol Univ, Belgaum, Karnataka, India
[3] Univ Sydney, Sch Chem & Biomol Engn, Sydney, NSW 2006, Australia
[4] Lamar Univ, Dept Chem & Biochem, Beaumont, TX 77710 USA
关键词
Sensor; Nanocomposite; Flufenamic acid; Mefenamic acid; Electro-oxidation; Voltammetry; FLOW-INJECTION ANALYSIS; ELECTROCHEMICAL SENSOR; PASTE ELECTRODE; PHARMACEUTICAL-PREPARATIONS; VOLTAMMETRIC DETERMINATION; SENSITIVE DETERMINATION; SELECTIVE DETERMINATION; ANTIINFLAMMATORY DRUGS; LIQUID-CHROMATOGRAPHY; GOLD NANOPARTICLES;
D O I
10.1016/j.aca.2018.11.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recent advances to utilize two or more nanoparticles for developing novel sensors with superior sensitivity have spurred advanced detection limits even at low concentrations. In this research, a blend of rutheniumdoped TiO2 (Ru-TiO2) nanoparticles and multiwalled carbon nanotubes (MWCNTs) loaded into carbon paste matrix to fabricate a novel Ru-TiO2/MWCNTs-CPE sensor was used for the detection and quantification of flufenamic acid (FFA) and mefenamic acid (MFA) drugs. The surface morphology of Ru-TiO2 was assessed by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), transmission electron microscopy (TEM), X-ray diffraction (XRD) and atomic force microscopy (AFM). Sensitivity and selectivity of the electrode was improved at the Ru-TiO2/MWCNTs modified CPE compared to nascent CPE due to the amazing surface distinctive characteristics of the modifier at pH 5.0. The effect of concentration of the modifier, pH, pre-concentration time, sweep rate and concentration on signal enhancement of FFA and MFA was studied. The square wave voltammetry (SWV) currents are linearly related in the concentration range of 0.01 mu M-0.9 mu M with the detection limit values of 0.68 nM for FFA and 0.45 nM for MFA, respectively. The developed electrode assembly was used for the quantification of both the drug analytes in human urine samples. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:58 / 72
页数:15
相关论文
共 65 条
  • [21] A novel and sensitive hexadecyltrimethylammoniumbromide functionalized Fe decorated MWCNTs modified carbon paste electrode for the selective determination of Quercetin
    Erady, Veera
    Mascarenhas, Ronald J.
    Satpati, Ashis K.
    Detriche, Simon
    Mekhalif, Zineb
    Delhalle, Joseph
    Dhason, A.
    [J]. MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 76 : 114 - 122
  • [22] Graham G.G., 2016, COMPENDIUM INFLAMMAT, P1, DOI [10.1007/978-3-0348-0620-6_24-1, DOI 10.1007/978-3-0348-0620-6_24-1]
  • [23] Preparation of a new electrochemical sensor based on iron (III) complexes modified carbon paste electrode for simultaneous determination of mefenamic acid and indomethacin
    Hasanzadeh, Mohammad
    Shadjou, Nasrin
    Saghatforoush, Lotfali
    Dolatabadi, Jafar Ezzati Nazhad
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2012, 92 : 91 - 97
  • [24] Crystallization monitoring by Raman spectroscopy: Simultaneous measurement of desupersaturation profile and polymorphic form in flufenamic acid systems
    Hu, YR
    Liang, JK
    Myerson, AS
    Taylor, LS
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2005, 44 (05) : 1233 - 1240
  • [25] Simultaneous voltammetric determination of paracetamol, cetirizine and phenylephrine using a multiwalled carbon nanotube-platinum nanoparticles nanocomposite modified carbon paste electrode
    Kalambate, Pramod K.
    Srivastava, Ashwini K.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2016, 233 : 237 - 248
  • [26] SENSORS BASED ON CARBON-PASTE IN ELECTROCHEMICAL ANALYSIS - A REVIEW WITH PARTICULAR EMPHASIS ON THE PERIOD 1990-1993
    KALCHER, K
    KAUFFMANN, JM
    WANG, J
    SVANCARA, I
    VYTRAS, K
    NEUHOLD, C
    YANG, Z
    [J]. ELECTROANALYSIS, 1995, 7 (01) : 5 - 22
  • [27] Liquid phase analysis of methyldopa in the presence of tyrosine using electrocatalytic effect of a catechol derivative at a surface of NiO nanoparticle modified carbon paste electrode
    Keyvanfard, Mohsen
    Hatami, Mehdi
    Gupta, Vinod Kumar
    Agarwal, Shilpi
    Sadeghifar, Hasan
    Khalilzadeh, Mohammad A.
    [J]. JOURNAL OF MOLECULAR LIQUIDS, 2017, 230 : 290 - 294
  • [28] SPECTROPHOTOMETRIC METHOD FOR THE DETERMINATION OF FLUFENAMIC AND MEFENAMIC ACIDS
    KHIER, AA
    ELSADEK, M
    BARAKA, M
    [J]. ANALYST, 1987, 112 (10) : 1399 - 1403
  • [29] Room Temperature Ionic Liquid/Multiwalled Carbon Nanotube/Chitosan-Modified Glassy Carbon Electrode as a Sensor for Simultaneous Determination of Ascorbic Acid, Uric Acid, Acetaminophen, and Mefenamic Acid
    Kianipour, Shokat
    Asghari, Alireza
    [J]. IEEE SENSORS JOURNAL, 2013, 13 (07) : 2690 - 2698
  • [30] Ru-TiO2 semiconducting nanoparticles for the photo-catalytic degradation of bromothymol blue
    Kulkarni, R. M.
    Malladi, R. S.
    Hanagadakar, M. S.
    Doddamani, M. R.
    Santhakumari, B.
    Kulkarni, S. D.
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2016, 27 (12) : 13065 - 13074