An experimental investigation on performance of annular fins on a horizontal cylinder in free convection heat transfer

被引:54
作者
Yildiz, S [1 ]
Yüncü, H [1 ]
机构
[1] Middle E Tech Univ, Dept Mech Engn, TR-06531 Ankara, Turkey
关键词
Rayleigh Number; Heat Transfer Rate; Horizontal Cylinder; Heat Transfer Area; High Temperature Difference;
D O I
10.1007/s00231-002-0404-x
中图分类号
O414.1 [热力学];
学科分类号
摘要
Natural convection heat transfer in annular fin-arrays mounted on a horizontal cylinder was experimentally investigated. An experimental set-up was constructed to investigate heat transfer characteristics of 18 sets of annular fin-arrays mounted on a horizontal cylinder of 24.9-mm diameter in atmospheric conditions. Keeping the fin thickness fixed at 1 mm, fin diameter is varied from 35 mm to 125 mm and fin spacing is varied from 3.6 mm to 31.7 mm. The base-to-ambient temperature difference was also varied with a calibrated wattmeter ranging from 25 W to 150 W. The results have shown that the convection heat transfer rate from the fin arrays depends on fin diameter, fin spacing and base-to-ambient temperature difference. In addition, for every fin diameter, for a given base-to-ambient temperature difference, there exists an optimum value for the fin spacing for which the heat transfer rate from the fin array is maximised. Experimental results show that, for practical engineering applications, the optimum fin spacing may be taken approximately as 8 mm. A scale analysis is also performed in order to estimate order-of-magnitude of optimum fin spacing at a given fin diameter and base-to-ambient temperature difference. The correlation obtained from scale analysis is the result of limited number of experiments. This correlation may be generalised by applying the order-of-magnitude analysis developed in this work for wider range of experiments.
引用
收藏
页码:239 / 251
页数:13
相关论文
共 21 条
[1]  
Bejan A., 1984, CONVECTION HEAT TRAN
[2]   CORRELATING EQUATIONS FOR LAMINAR AND TURBULENT FREE CONVECTION FROM A HORIZONTAL CYLINDER [J].
CHURCHILL, SW ;
CHU, HHS .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1975, 18 (09) :1049-1053
[3]   OPTIMUM SPACING OF FINS COOLED BY FREE CONVECTION [J].
FITZROY, ND .
JOURNAL OF HEAT TRANSFER, 1971, 93 (04) :462-&
[4]   An experimental investigation on performance of fins on a horizontal base in free convection heat transfer [J].
Güvenç, A ;
Yüncü, H .
HEAT AND MASS TRANSFER, 2001, 37 (4-5) :409-416
[5]   NATURAL CONVECTION HEAT TRANSFER FROM HORIZONTAL RECTANGULAR FIN ARRAYS [J].
HARAHAP, F ;
MCMANUS, HN .
JOURNAL OF HEAT TRANSFER, 1967, 89 (01) :32-&
[6]  
Incropera F.P., 1996, FUNDAMENTAL HEAT MAS, VFourth
[7]   OPTIMUM ARRANGEMENT OF RECTANGULAR FINS ON HORIZONTAL SURFACES FOR FREE-CONVECTION HEAT TRANSFER [J].
JONES, CD ;
SMITH, LF .
JOURNAL OF HEAT TRANSFER, 1970, 92 (01) :6-&
[8]   NUMERICAL AND EXPERIMENTAL-STUDY OF TURBULENT HEAT-TRANSFER AND FLUID-FLOW IN LONGITUDINAL FIN ARRAYS [J].
KADLE, DS ;
SPARROW, EM .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1986, 108 (01) :16-23
[9]  
KAKAC S, 1994, NATO ASI SERIES
[10]  
Kern D., 1972, EXTENDED SURFACE HEA