Hard X-ray micro(spectro)scopy: A powerful tool for the geomicrobiologists

被引:4
作者
Kemner, K. M. [1 ]
机构
[1] Argonne Natl Lab, Biosci Div, Argonne, IL 60439 USA
关键词
D O I
10.1111/j.1472-4669.2008.00145.x
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
During the past few decades, the use of electron microscopy approaches - many developed by Terry Beveridge - to probe the physiology of microorganisms has become a mainstay in fields including microbiology, human health, and geomicrobiology. Recent developments of third-generation synchrotron X-ray sources and X-ray-based microscopy approaches for studying microbial systems have proved their utility as complements to the very powerful approaches regularly employed by electron microscopists. In addition, in recent geomicrobiological studies, researchers have begun to take advantage of the strengths of each technique by using the superior spatial resolution of the electron microscope (relative to the X-ray microscope) and the superior elemental sensitivity of the X-ray microscope (relative to the electron microscope), along with the ability of the X-ray microscope to spatially probe the chemical speciation of elements. The benefits of integrating these two nanoprobes for investigating the same microenvironments within a geomicrobial system are far superior to those of independent studies separately employing each probe.
引用
收藏
页码:270 / 277
页数:8
相关论文
共 41 条
[11]  
Kemner K, 2007, AIP CONF PROC, V882, P250
[12]  
Kemner KM, 2007, MANUAL OF ENVIRONMENTAL MICROBIOLOGY, 3RD ED, P1183
[13]   Elemental and redox analysis of single bacterial cells by X-ray microbeam analysis [J].
Kemner, KM ;
Kelly, SD ;
Lai, B ;
Maser, J ;
O'Loughlin, EJ ;
Sholto-Douglas, D ;
Cai, ZH ;
Schneegurt, MA ;
Kulpa, CF ;
Nealson, KH .
SCIENCE, 2004, 306 (5696) :686-687
[14]   A LOW-TEMPERATURE TOTAL ELECTRON YIELD DETECTOR FOR X-RAY-ABSORPTION FINE-STRUCTURE SPECTRA [J].
KEMNER, KM ;
KROPF, J ;
BUNKER, BA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (12) :3667-3669
[15]   Using zone plates for X-ray microimaging and microspectroscopy in environmental science [J].
Kemner, KM ;
Yun, W ;
Cai, Z ;
Lai, B ;
Lee, HR ;
Maser, J ;
Legnini, DG ;
Rodrigues, W ;
Jastrow, JD ;
Miller, RM ;
Pratt, ST ;
Schneegurt, MA ;
Kulpa, CF .
JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 :639-641
[16]  
KEMNER KM, 1998, USING XRAY MICROPROB
[17]  
KEMNER KM, 2001, P 6 INT C BIOG TRAC
[18]  
KEMNER KM, 2000, USE HIGH ENERGY XRAY
[19]   SOFT-X-RAY MICROSCOPES AND THEIR BIOLOGICAL APPLICATIONS [J].
KIRZ, J ;
JACOBSEN, C ;
HOWELLS, M .
QUARTERLY REVIEWS OF BIOPHYSICS, 1995, 28 (01) :33-130
[20]  
Koningsberger D. C., 1987, XRAY ABSORPTION PRIN