Non invasive process probe for inline Raman monitoring through optical inspection glasses

被引:6
作者
Braun, Frank [1 ]
Schalk, Robert [1 ]
Brunner, Jochen [1 ]
Eckhardt, Hanns Simon [2 ]
Theuer, Michael [3 ]
Veith, Ute [3 ]
Hennig, Steffen [3 ]
Ferstl, Wolfgang [3 ]
Methner, Frank-Juergen [4 ]
Beuermann, Thomas [1 ]
Gretz, Norbert [5 ]
Raedle, Matthias [1 ]
机构
[1] Hsch Mannheim, Inst Prozessmesstech & Innovat Energiesyst PI, Paul Wittsack Str 10, D-68163 Mannheim, Germany
[2] Tec5 AG, Au 27, D-61440 Oberursel, Germany
[3] Fachzentrum Prozessanalysentech, BASF SE, Carl Bosch Str 38, D-67056 Ludwigshafen, Germany
[4] Tech Univ Berlin, Inst Lebensmitteltechnol & Lebensmittelchem, Fachgebiet Brauwesen, Seestr 13, D-13353 Berlin, Germany
[5] Heidelberg Univ, Zentrum Med Forsch, Med Fak Mannheim, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, Germany
关键词
Process analytical technology; Raman probe; Raman spectroscopy; inspection glass; non-invasive; SPECTROSCOPY; FERMENTATION;
D O I
10.1515/teme-2016-0011
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Raman spectroscopy features some significant advantages against existing spectroscopic techniques. Amongst them are higher chemical sensitivities compared to NIR and a relatively low detection range for water molecules, in contrast to MIR spectroscopy. In process installations, compared to all spectroscopic techniques Raman plays only a minor role. Main challenges for process integration are long-term stability of the available measurement systems, high installation costs of so-called immersion probes and the addition of measurement points to existing plant layouts in piping and vessels. After the implementation of probes, a technical clearance that consists of an acceptance and pressure test has to be carried out by external certification authorities. A practical alternative is demonstrated by a robust probe concept, which enables beam propagation through large aperture optics. Therefore, focal lengths exceeding 25 mm allow real-time measurement of samples from the outside of piping filled with analytes through optical windows in production plants. The potential of this new measurement option is tested exemplarily by the detection of ethanol through optical windows of various thicknesses. A quantitative real-time monitoring of a mixture of propylene carbonate in water through an inspection glass PN 16 was tested in a pilot plant scale. The presented Raman probe has a high potential for the use in industrial plants, as it allows a simple, cost-efficient and contact-free adaption to existing measurement points in process analytic technology and features a long service life.
引用
收藏
页码:593 / 605
页数:13
相关论文
共 17 条
  • [11] In situ monitoring by quantitative Raman spectroscopy of alcoholic fermentation by Saccharomyces cerevisiae under high pressure
    Picard, A.
    Daniel, I.
    Montagnac, G.
    Oger, P.
    [J]. EXTREMOPHILES, 2007, 11 (03) : 445 - 452
  • [12] Pouchert C.J., 1997, ALDRICH LIB FT IR SP
  • [13] Rankin D. W. H., 2009, CRC handbook of chemistry and physics, V15, P223, DOI [10.1080/08893110902764125, DOI 10.1080/08893110902764125]
  • [14] Organic Carbonates as Solvents in Synthesis and Catalysis
    Schaeffner, Benjamin
    Schaeffner, Friederike
    Verevkin, Sergey P.
    Boerner, Armin
    [J]. CHEMICAL REVIEWS, 2010, 110 (08) : 4554 - 4581
  • [15] Fast and Efficient Acquisition of Kinetic Data in Microreactors Using In-Line Raman Analysis
    Schwolow, Sebastian
    Braun, Frank
    Raedle, Matthias
    Kockmann, Norbert
    Roeder, Thorsten
    [J]. ORGANIC PROCESS RESEARCH & DEVELOPMENT, 2015, 19 (09) : 1286 - 1292
  • [16] ATR photometer for the detection of isocyanate concentrations in process applications
    Theuer, Michael
    Hennig, Steffen
    Ferstl, Wolfgang
    Konz, Werner
    Lambrecht, Armin
    [J]. TM-TECHNISCHES MESSEN, 2015, 82 (01) : 16 - 23
  • [17] Applications of Raman spectroscopy in pharmaceutical analysis
    Vankeirsbilck, T
    Vercauteren, A
    Baeyens, W
    Van der Weken, G
    Verpoort, F
    Vergote, G
    Remon, JP
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2002, 21 (12) : 869 - 877