Variation of modal parameters of a cable-stayed bridge identified from ambient vibration measurements and FE modelling

被引:90
作者
Macdonald, JHG [1 ]
Daniell, WE [1 ]
机构
[1] Univ Bristol, Dept Civil Engn, Bristol BS8 1TR, Avon, England
基金
英国工程与自然科学研究理事会;
关键词
cable-stayed bridge; modal parameters; ambient vibration test; damping; finite element model; aeroelastic coupling;
D O I
10.1016/j.engstruct.2005.06.007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
During construction, the first cantilever of the Second Severn Crossing cable-stayed bridge was monitored for dynamic effects. Modal parameters of many modes were identified from ambient vibration measurements, and mode shapes and natural frequencies were matched with modes from a Finite Element (FE) model. The accuracy of the measured natural frequencies and damping ratios was estimated, and variations in these parameters were identified from long-term records. The contributions of aerodynamic and structural damping were separated, and the magnitude of the components is discussed. Variations in natural frequencies with wind velocity and, for the finished bridge, traffic loading were identified, but no changes due to temperature were detected, although the temperature range experienced was small. The variations are compared with results from the FE analysis and the significance of the measurement accuracy and natural variations are discussed in relation to Model Updating and Structural Health Monitoring. Finally, evidence of aeroelastic coupling of vertical and torsional modes, during construction, is presented. This arose as the natural frequencies of the two modes were much closer than anticipated, highlighting the need for detailed FE modelling to determine this important frequency ratio accurately. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1916 / 1930
页数:15
相关论文
共 28 条
[1]  
Bendat JS., 2011, RANDOM DATA ANAL MEA
[3]   Civil structure condition assessment by FE model updating: methodology and case studies [J].
Brownjohn, JMW ;
Xia, PQ ;
Hao, H ;
Xia, Y .
FINITE ELEMENTS IN ANALYSIS AND DESIGN, 2001, 37 (10) :761-775
[4]  
Daniell WE, 1999, EARTHQUAKE ENG STRUC, V28, P1327, DOI 10.1002/(SICI)1096-9845(199911)28:11<1327::AID-EQE869>3.3.CO
[5]  
2-M
[6]  
DANIELL WE, UNPUB ENG STRUCT
[7]  
Davenport A G, 1962, Proceedings of the Institution of Civil Engineers, V23, P389, DOI [10.1680/iicep.1962.10876, DOI 10.1680/IICEP.1962.10876]
[8]  
ERNST MJ, 1965, BAUINGENIEUR-GERMANY, V40, P52
[9]  
HOLMES JD, 1975, P 4 INT C WIND EFF B, P187
[10]  
IRWIN PA, 1994, P INT C CABL STAYED, V2, P143