Ultra trace analysis of small molecule by label-free impedimetric immunosensor using multilayer modified electrode

被引:27
作者
Chullasat, Kochaporn [3 ,4 ,5 ]
Kanatharana, Proespichaya [3 ,4 ,5 ]
Limbut, Warakorn [2 ,4 ,5 ]
Numnuam, Apon [3 ,4 ,5 ]
Thavarungkul, Panote [1 ,4 ,5 ]
机构
[1] Prince Songkla Univ, Fac Sci, Dept Phys, Hat Yai 90112, Songkhla, Thailand
[2] Prince Songkla Univ, Fac Sci, Dept Appl Sci, Hat Yai 90112, Songkhla, Thailand
[3] Prince Songkla Univ, Fac Sci, Dept Chem, Hat Yai 90112, Songkhla, Thailand
[4] Prince Songkla Univ, Fac Sci, Ctr Excellence Innovat Chem, Hat Yai 90112, Songkhla, Thailand
[5] Prince Songkla Univ, Trace Anal & Biosensor Res Ctr, Hat Yai 90112, Songkhla, Thailand
关键词
Label-free; Trace analysis; Small molecule; Chloramphenicol; Impedance biosensor; Sensitivity enhancement; IMPEDANCE SPECTROSCOPY; INTERFERON-GAMMA; CHLORAMPHENICOL; CONFIRMATION; AU; IDENTIFICATION; RESIDUES; THIOUREA; MUSCLE; LIVER;
D O I
10.1016/j.bios.2011.05.029
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A multilayer electrode modified with a self-assembled thiourea monolayer (SATUM) followed by gold nanoparticles (AuNPs), mercaptosuccinic acid (MSA) and antibody was investigated for the detection of ultra trace amount of a small molecule (chloramphenicol) in an impedimetric system. The formation of the antibody-antigen complex at the electrode surface caused the impedance to increase. Under optimum conditions three modified electrodes were compared the SATUM/AuNPs/MSA electrode provided a wide linear range (0.50-10) x 10(-16) M, and a very low determination limit of 1.0 x 10(-16) M. This determination limit was much lower than the SATUM/AuNPs electrode, 1.0 x 10(-15) M, and SATUM electrode, 4.7 x 10(-14) M. The modified electrode provided good selectivity for chloramphenicol detection and can be reused up to 45 times with a relative standard deviation of lower than 4%. When applied to determine chloramphenicol in shrimp samples, the results agreed well with those obtained by the high-performance liquid chromatography coupled with a photo diode array detector (P > 0.05). The developed system can be applied to detect other small molecules using appropriate affinity binding pairs. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:4571 / 4578
页数:8
相关论文
共 34 条
[1]  
[Anonymous], 2003, OFF J EUR COMMUN L, VL71, P17
[2]   On the response of a label-free interferon-γ immunosensor utilizing electrochemical impedance spectroscopy [J].
Bart, M ;
Stigter, ECA ;
Stapert, HR ;
de Jong, GJ ;
van Bennekom, WP .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (01) :49-59
[3]  
Berggren C, 2001, ELECTROANAL, V13, P173, DOI 10.1002/1521-4109(200103)13:3<173::AID-ELAN173>3.0.CO
[4]  
2-B
[5]   Capacitance measurements of antibody-antigen interactions in a flow system [J].
Berggren, C ;
Johansson, G .
ANALYTICAL CHEMISTRY, 1997, 69 (18) :3651-3657
[6]  
Cunningham A.J., 1998, INTRO BIOANALYTICAL
[7]   Label-free impedance biosensors: Opportunities and challenges [J].
Daniels, Jonathan S. ;
Pourmand, Nader .
ELECTROANALYSIS, 2007, 19 (12) :1239-1257
[8]   Development of an electrochemical immunosensor for direct detection of interferon-γ at the attomolar level [J].
Dijksma, M ;
Kamp, B ;
Hoogvliet, JC ;
van Bennekom, WP .
ANALYTICAL CHEMISTRY, 2001, 73 (05) :901-907
[9]  
Eurachem W.G., 1998, EURACHEM GUID
[10]   Detection of chloramphenicol and chloramphenicol glucuronide residues in poultry muscle, honey, prawn and milk using a surface plasmon resonance biosensor and Qflex® kit chloramphenicol [J].
Ferguson, J ;
Baxter, A ;
Young, P ;
Kennedy, G ;
Elliott, C ;
Weigel, S ;
Gatermann, R ;
Ashwind, H ;
Stead, S ;
Sharman, M .
ANALYTICA CHIMICA ACTA, 2005, 529 (1-2) :109-113