Mass Transport in a Micro Flow-Through Vial of a Junction-at-the-Tip Capillary Electrophoresis-Mass Spectrometry Interface

被引:64
|
作者
Zhong, Xuefei [1 ]
Maxwell, E. Jane [1 ]
Chen, David D. Y. [1 ]
机构
[1] Univ British Columbia, Dept Chem, Vancouver, BC V6T 1Z1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
MICELLAR ELECTROKINETIC CHROMATOGRAPHY; ZONE-ELECTROPHORESIS; MS; CE; PERFORMANCE; PEPTIDES; DESIGN;
D O I
10.1021/ac200636y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
When coupling capillary electrophoresis with postcolumn detection methods, such as mass spectrometry, the presence of postcolumn band broadening must be considered. The band broadening effects introduced by junction-at-the-tip CE-MS interfaces using a postcolumn micro flow-through vial are investigated by studying the hydrodynamic flow patterns and mass transport process inside the micro vial at the end of the CE separation capillary. Simulation results obtained by solving the Navier-Stokes and mass balance equations provide insights into the velocity field and concentration distribution of the analytes in the micro vial and demonstrate that, with a low flow rate of chemical modifier solution, the laminar flow streams confine the analyte molecules to the central part of the micro vial and thus maintain major features of the peak shapes. Peaks detected by UV and MS under similar experimental conditions were compared to verify the numerical prediction that the main features of the UV peak can be retained in the MS peak Experiments also show that band broadening can be minimized when an appropriate chemical modifier flow rate is selected.
引用
收藏
页码:4916 / 4923
页数:8
相关论文
共 50 条
  • [1] Capillary electrophoresis-mass spectrometry using a flow-through microvial interface for cationic metabolome analysis
    Lindenburg, Petrus W.
    Ramautar, Rawi
    Jayo, Roxana G.
    Chen, David D. Y.
    Hankemeier, Thomas
    ELECTROPHORESIS, 2014, 35 (09) : 1308 - 1314
  • [2] Modified liquid junction interface for nonaqueous capillary electrophoresis-mass spectrometry
    Jussila, M
    Sinervo, K
    Porras, SP
    Riekkola, ML
    ELECTROPHORESIS, 2000, 21 (15) : 3311 - 3317
  • [3] Electrospray ionization stability and concentration sensitivity in capillary electrophoresis-mass spectrometry using a flow-through microvial interface
    Wang, Lingyu
    Li, Yueyang
    Chen, Dazhou
    Chen, David Da Yong
    ELECTROPHORESIS, 2021, 42 (04) : 360 - 368
  • [4] Simple Capillary Electrophoresis-Mass Spectrometry Method for Complex Glycan Analysis Using a Flow-Through Microvial Interface
    Jayo, Roxana G.
    Thaysen-Andersen, Morten
    Lindenburg, Petrus W.
    Haselberg, Rob
    Hankemeier, Thomas
    Ramautar, Rawi
    Chen, David D. Y.
    ANALYTICAL CHEMISTRY, 2014, 86 (13) : 6479 - 6486
  • [5] CAPILLARY ZONE ELECTROPHORESIS-MASS SPECTROMETRY
    OLIVARES, JA
    NGUYEN, NT
    SMITH, RD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 204 - ANYL
  • [6] Quantitation in capillary electrophoresis-mass spectrometry
    Ohnesorge, J
    Neusüss, C
    Wätzig, H
    ELECTROPHORESIS, 2005, 26 (21) : 3973 - 3987
  • [7] Nonaqueous capillary electrophoresis-mass spectrometry
    Scriba, Gerhard K. E.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1159 (1-2) : 28 - 41
  • [8] Microfabricated liquid junction hybrid capillary electrophoresis-mass spectrometry interface for fully automated operation
    Krenkova, Jana
    Kleparnik, Karel
    Luksch, Jaroslav
    Foret, Frantisek
    ELECTROPHORESIS, 2019, 40 (18-19) : 2263 - 2270
  • [9] A gold foil covered fused silica capillary tip as a sheathless interface for coupling capillary electrophoresis-mass spectrometry
    Zhang, Hanzhi
    Lou, Chunli
    Li, Jing
    Kang, Jingwu
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1624
  • [10] Special issue: Capillary electrophoresis-mass spectrometry
    Klampfl, Christian W.
    ELECTROPHORESIS, 2008, 29 (10) : 1955 - 1955