Pulpal temperature increases with Er:YAG laser and high-speed handpieces

被引:59
作者
Cavalcanti, BN
Lage-Marques, JL
Rode, SM
机构
[1] Sao Paulo State Univ, Sch Dent, Dept Dent Mat & Prosthet, Sao Paulo, Brazil
[2] Univ Sao Paulo, Dept Operat Dent, Sao Paulo, Brazil
[3] Ibirapuera Univ, Sao Paulo, Brazil
关键词
POWERED HYDROKINETIC SYSTEM; CAVITY PREPARATION; DENTAL-PULP; ERBIUM; ABLATION; TOOTH; RADIATION; DENTISTRY; CHAMBER; TISSUE;
D O I
10.1016/j.prosdent.2003.08.022
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. During tooth preparation, both high-speed handpieces and lasers generate heat, which, if not controlled, can cause pulpal necrosis. Purpose. The aim of this study was to compare temperature increases produced by a high-speed dental handpiece with those produced by a relatively new instrument, the Er:YAG (erbium: yttrium-aluminum-garnet) laser. Material and methods. Thirty bovine mandibular incisors were reduced to an enamel/dentin thickness of 2.5 mm. Class V preparations were completed to a depth of 2.0 mm, measured with a caliper or by a mark oil the burs. A thermocouple was placed inside the pulp chamber to determine temperature increases (degreesC). Analysis was performed on the following groups (n = 10): Group 1, high-speed handpiece without water cooling, Group 11, high-speed handpiece with water cooling (30 mL/min), and Group III, the noncontact Er:YAG laser (2.94 mum at 350 mJ/10 Hz) with water cooling (4.5 mL/min). The temperature increases were recorded by a computer linked to the thermocouples. The data were analyzed using the Kruskal-Wallis test. The Dunn multiple comparison test was used as post hoc test (alpha = .05). Results. The average temperature rises were: 11.64degreesC (+/-4.35) for Group 1, 0.96degreesC (+/-0.71) for Group 11, and 2.69degreesC (+/-1.12) for Group III. There were no statistical differences between Groups 11 and III, both 11 and III differed from Group I significantly (P = .000 and P = .002, respectively). Conclusion. The preparations made with the high-speed and the laser instrument generated similar heat increases under water cooling. Water cooling was essential to avoid destructive temperature increases when using both the high-speed handpiece and laser.
引用
收藏
页码:447 / 451
页数:5
相关论文
共 30 条
[1]   LASER AND DENTAL PULP [J].
ADRIAN, JC ;
BERNIER, JL ;
SPRAGUE, WG .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1971, 83 (01) :113-+
[2]  
ANIC I, 1992, CARIES RES, V26, P165
[3]   WET VERSUS DRY ENAMEL ABLATION BY ER-YAG LASER [J].
BURKES, EJ ;
HOKE, J ;
GOMES, E ;
WOLBARSHT, M .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 67 (06) :847-851
[4]   High-speed cavity preparation techniques with different water flows [J].
Cavalcanti, BN ;
Otani, C ;
Rode, SM .
JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (02) :158-161
[5]  
Chang JC, 1998, LASER SURG MED, V22, P46, DOI 10.1002/(SICI)1096-9101(1998)22:1<46::AID-LSM11>3.0.CO
[6]  
2-6
[7]   Dentistry for the 21st century? Erbium:YAG laser for teeth [J].
Cozean, C ;
Arcoria, CJ ;
Pelagalli, J ;
Powell, GL .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1997, 128 (08) :1080-1087
[8]  
Dostalova Tatjana, 1996, Scanning Microscopy, V10, P285
[9]   Pulpal response to cavity preparation by an erbium, chromium:YSGG laser-powered hydrokinetic system [J].
Eversole, LR ;
Rizoiu, I ;
Kimmel, AI .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1997, 128 (08) :1099-1106
[10]   Intrapulpal temperature during preparation with the Er:YAG laser compared to the conventional burr:: An in vitro study [J].
Glockner, K ;
Rumpler, J ;
Ebeleseder, K ;
Stadtler, P .
JOURNAL OF CLINICAL LASER MEDICINE & SURGERY, 1998, 16 (03) :153-157