Liquid chromatography coupled to Venturi easy ambient sonic spray ionization mass spectrometry

被引:2
作者
Campos Oliveira, Luan Felipe [1 ]
Tega, David Ulisses [1 ]
Eberlin, Marcos Nogueira [2 ]
Sussulini, Alessandra [1 ]
机构
[1] Univ Campinas UNICAMP, Inst Chem, Dept Analyt Chem, Lab Bioanalyt & Integrated Omics LaBI, BR-13083970 Campinas, SP, Brazil
[2] Univ Prebiteriana Mackenzie, Sch Engn, BR-01302907 Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Venturi easy ambient sonic-spray ionization; mass spectrometry; Annatto analysis; Liquid chromatography; Analytical methods; Ambient ionization; REAL-TIME ANALYSIS; INTERFACE; ASPIRATION; TISSUE; MS;
D O I
10.1016/j.talanta.2021.123004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Venturi easy ambient sonic spray ionization (V-EASI) is a soft ambient ionization (AI) source that has the advantages of being suitable to the analysis of samples in solution (differently from the majority of AI sources), performing self-pumping, voltage- and heat-free ionization, and requiring minimum or no sample preparation. Since this ionization technique has not been fully explored, the present study provides a proof of principle of the coupling of liquid chromatography to mass spectrometry (LC-MS) using V-EASI as the interface. In order to test the performance of the developed LC-V-EASI-MS system, a quantification method for bixin, a natural dye from annatto (Bixa Orellana L.), which is known to be sensitive to the high voltage applied for electrospray ionization mass spectrometry (ESI-MS) analysis, was validated according to FDA criteria and tested in real samples. The analytical method was successfully applied and met the validation criteria, providing a detectability 10 times better than methods already reported to the quantification of bixin and no matrix effect was observed. Therefore, this proof of principle contributes to the continuous development of AI sources that represents the last great technological advance in MS towards becoming a miniaturized technique able to analyze samples closer to their actual state.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Determination and characterization of diuretics in human urine by liquid chromatography coupled to pneumatically assisted electrospray ionization mass spectrometry
    Sanz-Nebot, V
    Toro, I
    Bergés, R
    Ventura, R
    Segura, J
    Barbosa, J
    JOURNAL OF MASS SPECTROMETRY, 2001, 36 (06): : 652 - 657
  • [32] A novel method to distinguish β-methylphenylethylamines from isomeric α-methylphenylethylamines by liquid chromatography coupled to electrospray ionization mass spectrometry
    Tsumura, Yukari
    Kiguchi, Akio
    Komatsuzaki, Satoshi
    Ieuji, Kei
    FORENSIC TOXICOLOGY, 2020, 38 (02) : 465 - 474
  • [33] Ambient ionization mass spectrometry
    Lebedev, A. T.
    RUSSIAN CHEMICAL REVIEWS, 2015, 84 (07) : 665 - 692
  • [34] Recent developments in DNA adduct analysis using liquid chromatography coupled with mass spectrometry
    Tang, Yu
    Zhang, Jin-Lan
    JOURNAL OF SEPARATION SCIENCE, 2020, 43 (01) : 31 - 55
  • [35] Lipidomics of the Edible Brown Alga Wakame (Undaria pinnatifida) by Liquid Chromatography Coupled to Electrospray Ionization and Tandem Mass Spectrometry
    Coniglio, Davide
    Bianco, Mariachiara
    Ventura, Giovanni
    Calvano, Cosima D.
    Losito, Ilario
    Cataldi, Tommaso R., I
    MOLECULES, 2021, 26 (15):
  • [36] Determination of sulfonamides in beeswax by liquid chromatography coupled to tandem mass spectrometry
    Mitrowska, Kamila
    Antczak, Maja
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 1006 : 179 - 186
  • [37] Determination of halogenated flame retardants by liquid chromatography coupled to mass spectrometry
    Guerra, P.
    Eljarrat, E.
    Barcelo, D.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2011, 30 (06) : 842 - 855
  • [38] Capillary Vibrating Sharp-Edge Spray Ionization (cVSSI) for Voltage-Free Liquid Chromatography-Mass Spectrometry
    Ranganathan, Nandhini
    Li, Chong
    Suder, Timothy
    Karanji, Ahmad K.
    Li, Xiaojun
    He, Ziyi
    Valentine, Stephen J.
    Li, Peng
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2019, 30 (05) : 824 - 831
  • [39] A validated assay for the quantitative analysis of tranexamic acid in human serum by liquid chromatography coupled with electrospray ionization mass spectrometry
    Grassin Delyle, Stanislas
    Abe, Emuri
    Batisse, Anne
    Tremey, Benjamin
    Fischler, Marc
    Devillier, Philippe
    Alvarez, Jean Claude
    CLINICA CHIMICA ACTA, 2010, 411 (5-6) : 438 - 443
  • [40] Dual-channel chromatography a smart way to improve the analysis efficiency in liquid chromatography coupled to mass spectrometry
    Rajski, Lukasz
    Jesus, Florencia
    Jose Diaz-Galiano, Francisco
    Rodriguez Fernandez-Alba, Amadeo
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1633