Evaluation of Sinus/Edge-Corrected Zero-Echo-Time-Based Attenuation Correction in Brain PET/MRI

被引:42
作者
Yang, Jaewon [1 ]
Wiesinger, Florian [2 ]
Kaushik, Sandeep [3 ]
Shanbhag, Dattesh [3 ]
Hope, Thomas A. [1 ]
Larson, Peder E. Z. [1 ]
Seo, Youngho [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, 185 Berry St,Suite 350, San Francisco, CA 94107 USA
[2] GE Global Res, Munich, Germany
[3] GE Global Res, Bangalore, Karnataka, India
关键词
neurology; PET; PET/MRI; ZTE; attenuation correction; brain; F-18-FDG PET/MRI; BONE; PET; MRI; MODEL; IMAGE; BIAS;
D O I
10.2967/jnumed.116.188268
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In brain PET/MRI, the major challenge of zero-echo-time (ZTE)-based attenuation correction (ZTAC) is the misclassification of air/tissue/bone mixtures or their boundaries. Our study aimed to evaluate a sinus/edge-corrected (SEC) ZTAC (ZTAC(SEC)), relative to an uncorrected (UC) ZTAC (ZTAC(UC)) and a CT atlas-based attenuation correction (ATAC). Methods: Whole-body F-18-FDG PET/MRI scans were obtained for 12 patients after PET/CT scans. Only data acquired at a bed station that included the head were used for this study. Using PET data from PET/MRI, we applied ZTAC(UC), ZTAC(SEC), ATAC, and reference CT-based attenuation correction (CTAC) to PET attenuation correction. For ZTAC(UC), the bias-corrected and normalized ZTE was converted to pseudo-CT with air (-1,000 HU for ZTE < 0.2), soft-tissue (42 HU for ZTE > 0.75), and bone (-2,000 x [ZTE - 1] + 42 HU for 0.2 <= ZTE <= 0.75). Afterward, in the pseudo-CT, sinus/edges were automatically estimated as a binary mask through morphologic processing and edge detection. In the binary mask, the overestimated values were rescaled below 42 HU for ZTAC(SEC). For ATAC, the atlas deformed to MR in-phase was segmented to air, inner air, soft tissue, and continuous bone. For the quantitative evaluation, PET mean uptake values were measured in twenty 1-mL volumes of interest distributed throughout brain tissues. The PET uptake was compared using a paired t test. An error histogram was used to show the distribution of voxel-based PET uptake differences. Results: Compared with CTAC, ZTAC(SEC) achieved the overall PET quantification accuracy (0.2% +/- 2.4%, P = 0.23) similar to CTAC, in comparison with ZTAC(UC) (5.6% +/- 3.5%, P < 0.01) and ATAC (-0.9% +/- 5.0%, P = 0.03). Specifically, a substantial improvement with ZTAC(SEC) (0.6% +/- 2.7%, P < 0.01) was found in the cerebellum, in comparison with ZTAC(UC) (8.1% +/- 3.5%, P < 0.01) and ATAC (-4.1% +/- 4.3%, P < 0.01). The histogram of voxel-based uptake differences demonstrated that ZTAC(SEC) reduced the magnitude and variation of errors substantially, compared with ZTAC(UC) and ATAC. Conclusion: ZTAC(SEC) can provide an accurate PET quantification in brain PET/MRI, comparable to the accuracy achieved by CTAC, particularly in the cerebellum.
引用
收藏
页码:1873 / 1879
页数:7
相关论文
共 25 条
  • [1] Combined PET/MR imaging in neurology: MR-based attenuation correction implies a strong spatial bias when ignoring bone
    Andersen, Flemming Littrup
    Ladefoged, Claes Nohr
    Beyer, Thomas
    Keller, Sune Hogild
    Hansen, Adam Espe
    Hojgaard, Liselotte
    Kjaer, Andreas
    Law, Ian
    Holm, Soren
    [J]. NEUROIMAGE, 2014, 84 : 206 - 216
  • [2] Avants BB, 2009, INSIGHT J, V2, P1, DOI 10.54294/uvnhin
  • [3] Attenuation correction in emission tomography using the emission data-A review
    Berker, Yannick
    Li, Yusheng
    [J]. MEDICAL PHYSICS, 2016, 43 (02) : 807 - 832
  • [4] MR-Based PET Attenuation Correction for PET/MR Imaging
    Bezrukov, Ilja
    Mantlik, Frederic
    Schmidt, Holger
    Schoelkopf, Bernhard
    Pichler, Bernd J.
    [J]. SEMINARS IN NUCLEAR MEDICINE, 2013, 43 (01) : 45 - 59
  • [5] Attenuation Correction Synthesis for Hybrid PET-MR Scanners: Application to Brain Studies
    Burgos, Ninon
    Cardoso, M. Jorge
    Thielemans, Kris
    Modat, Marc
    Pedemonte, Stefano
    Dickson, John
    Barnes, Anna
    Ahmed, Rebekah
    Mahoney, Colin J.
    Schott, Jonathan M.
    Duncan, John S.
    Atkinson, David
    Arridge, Simon R.
    Hutton, Brian F.
    Ourselin, Sebastien
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (12) : 2332 - 2341
  • [6] Qualitative and quantitative ultrashort echo time (UTE) imaging of cortical bone
    Du, Jiang
    Carl, Michael
    Bydder, Mark
    Takahashi, Atsushi
    Chung, Christine B.
    Bydder, Graeme M.
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2010, 207 (02) : 304 - 311
  • [7] NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system
    Grant, Alexander M.
    Deller, Timothy W.
    Khalighi, Mohammad Mehdi
    Maramraju, Sri Harsha
    Delso, Gaspar
    Levin, Craig S.
    [J]. MEDICAL PHYSICS, 2016, 43 (05) : 2334 - 2343
  • [8] Iagaru A, 2015, CLIN NUCL MED, V40, P1, DOI 10.1097/RLU.0000000000000611
  • [9] Dixon Sequence with Superimposed Model-Based Bone Compartment Provides Highly Accurate PET/MR Attenuation Correction of the Brain
    Koesters, Thomas
    Friedman, Kent P.
    Fenchel, Matthias
    Zhan, Yiqiang
    Hermosillo, Gerardo
    Babb, James
    Jelescu, Ileana O.
    Faul, David
    Boada, Fernando E.
    Shepherd, Timothy M.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (06) : 918 - 924
  • [10] Region specific optimization of continuous linear attenuation coefficients based on UTE (RESOLUTE): application to PET/MR brain imaging
    Ladefoged, Claes N.
    Benoit, Didier
    Law, Ian
    Holm, Soren
    Kjaer, Andreas
    Hojgaard, Liselotte
    Hansen, Adam E.
    Andersen, Flemming L.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (20) : 8047 - 8065