摘要
Elevated intraocular pressure (IOP) is an important risk factor for glaucoma. However, the role of IOP in glaucoma progression, as well as retinal physiology in general, remains incompletely understood. We demonstrate the use of visible light optical coherence tomography to measure retinal responses to acute IOP elevation in Brown Norway rats. We monitored retinal responses in reflectivity, angiography, blood flow, oxygen saturation (sO(2)), and oxygen metabolism over a range of IOP from 10 to 100 mmHg. As IOP was elevated, nerve fiber layer reflectivity was found to decrease. Vascular perfusion in the three retinal capillary plexuses remained steady until IOP exceeded 70 mmHg and arterial flow was noted to reverse periodically at high IOPs. However, a significant drop in total retinal blood flow was observed first at 40 mmHg. As IOP increased, the venous sO(2) demonstrated a gradual decrease despite steady arterial sO(2), which is consistent with increased arterial-venous oxygen extraction across the retinal capillary beds. Calculated total retinal oxygen metabolism was steady, reflecting balanced responses of blood flow and oxygen extraction, until IOP exceeded 40 mmHg, and fell to 0 at 70 and 80 mmHg. Above this, measurements were unattainable. All measurements reverted to baseline when the IOP was returned to 10 mmHg, indicating good recovery following acute pressure challenge. These results demonstrate the ability of this system to monitor retinal oxygen metabolism noninvasively and how it can help us understand retinal responses to elevated IOP. (C) The Authors. Published by SPIE undera Creative Commons Attribution 4.0 Unported License.
引用
收藏
页数:10
相关论文
共 60 条
[1]   Evaluation of Retinal Nerve Fiber Layer Thickness and Axonal Transport 1 and 2 Weeks After 8 Hours of Acute Intraocular Pressure Elevation in Rats [J].
Abbott, Carla J. ;
Choe, Tiffany E. ;
Lusardi, Theresa A. ;
Burgoyne, Claude F. ;
Wang, Lin ;
Fortune, Brad .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (02) :674-687
[2]   A literature review and novel theoretical approach on the optical properties of whole blood [J].
Bosschaart, Nienke ;
Edelman, Gerda J. ;
Aalders, Maurice C. G. ;
van Leeuwen, Ton G. ;
Faber, Dirk J. .
LASERS IN MEDICAL SCIENCE, 2014, 29 (02) :453-479
[3]   Relationship between the Magnitude of Intraocular Pressure during an Episode of Acute Elevation and Retinal Damage Four Weeks later in Rats [J].
Bui, Bang V. ;
Batcha, Abrez H. ;
Fletcher, Erica ;
Wong, Vickie H. Y. ;
Fortune, Brad .
PLOS ONE, 2013, 8 (07)
[4]   Retinal oximetry in humans using visible-light optical coherence tomography [Invited] [J].
Chen, Siyu ;
Shu, Xiao ;
Nesper, Peter L. ;
Liu, Wenzhong ;
Fawzi, Amani A. ;
Zhang, Hao F. .
BIOMEDICAL OPTICS EXPRESS, 2017, 8 (03) :1415-1429
[5]   Measuring oxygen saturation in retinal and choroidal circulations in rats using visible light optical coherence tomography angiography [J].
Chen, Siyu ;
Yi, Ji ;
Zhang, Hao F. .
BIOMEDICAL OPTICS EXPRESS, 2015, 6 (08) :2840-2853
[6]   Ultrahigh resolution retinal imaging by visible light OCT with longitudinal achromatization [J].
Chong, Shau Poh ;
Zhang, Tingwei ;
Kho, Aaron ;
Bernucci, Marcel T. ;
Dubra, Alfredo ;
Srinivasan, Vivek J. .
BIOMEDICAL OPTICS EXPRESS, 2018, 9 (04) :1477-1491
[7]   Structural and functional human retinal imaging with a fiber-based visible light OCT ophthalmoscope [J].
Chong, Shau Poh ;
Bernucci, Marcel ;
Radhakrishnan, Harsha ;
Srinivasan, Vivek J. .
BIOMEDICAL OPTICS EXPRESS, 2017, 8 (01) :323-337
[8]   Quantitative microvascular hemoglobin mapping using visible light spectroscopic Optical Coherence Tomography [J].
Chong, Shau Poh ;
Merkle, Conrad W. ;
Leahy, Conor ;
Radhakrishnan, Harsha ;
Srinivasan, Vivek J. .
BIOMEDICAL OPTICS EXPRESS, 2015, 6 (04) :1429-1450
[9]   An acute intraocular pressure challenge to assess retinal ganglion cell injury and recovery in the mouse [J].
Crowston, Jonathan G. ;
Kong, Yu Xiang G. ;
Trounce, Ian A. ;
Dang, Trung M. ;
Fahy, Eamonn T. ;
Bui, Bang V. ;
Morrison, John C. ;
Chrysostomou, Vicki .
EXPERIMENTAL EYE RESEARCH, 2015, 141 :3-8
[10]   Posterior rat eye during acute intraocular pressure elevation studied using polarization sensitive optical coherence tomography [J].
Fialova, Stanislava ;
Augustin, Marco ;
Fischak, Corinna ;
Schmetterer, Leopold ;
Handschuh, Stephan ;
Glosmann, Martin ;
Pircher, Michael ;
Hitzenberger, Christoph K. ;
Baumann, Bernhard .
BIOMEDICAL OPTICS EXPRESS, 2017, 8 (01) :298-314