A semiautomatic method for rapid segmentation of velocity-encoded myocardial magnetic resonance imaging data

被引:10
作者
Espe, Emil K. S. [1 ,2 ]
Skardal, Kristine [1 ,2 ]
Aronsen, Jan Magnus [3 ]
Zhang, Lili [1 ,2 ]
Sjaastad, Ivar [1 ,2 ]
机构
[1] Oslo Univ Hosp, Inst Expt Med Res, Oslo, Norway
[2] Univ Oslo, Oslo, Norway
[3] Bjorknes Coll, Oslo, Norway
关键词
magnetic resonance imaging; MRI; tissue phase mapping; postprocessing; segmentation; phase contrast; PHASE-CONTRAST MRI; MOTION; TRACKING; QUANTIFICATION; HEART; DENSE;
D O I
10.1002/mrm.26486
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop a semiautomatic method for rapid segmentation of myocardial tissue phase mapping (TPM) data. MethodsManual segmentation of the myocardium was performed at end-diastole and end-systole. The points in both user-defined masks were then automatically tracked over the entire cardiac cycle using temporal integration of the velocity field. Paths that failed to visit both masks at the expected times were excluded, after which masks for all time points were generated automatically from the accepted paths. Midventricular and basal phase contrast TPM slices from 12 rats were segmented using the proposed method and fully manual segmentation. The results were compared using Dice's metric and Bland-Altman analysis, and interobserver variability was assessed. ResultsThe semiautomatic method reduced the average user input time from 21min to 1min per slice. The Dice metrics between the methods were 0.880.03 (midventricular) and 0.83 +/- 0.06 (basal), and Bland-Altman limits of agreement of peak systolic and diastolic regional velocities were: midventricular: 0.05 +/- 0.65cm/s, -0.02 +/- 0.42cm/s, and -0.03 +/- 0.40cm/s (radial, tangential, longitudinal); basal: -0.04 +/- 0.73cm/s, 0.03 +/- 0.60cm/s, and -0.04 +/- 0.48cm/s (radial, tangential, longitudinal). Interobserver variability following semiautomatic segmentation was lower than for manual segmentation. ConclusionThe proposed method reduced the segmentation time substantially and exhibited well-preserved data quality and excellent interobserver limits of agreement. Magn Reson Med 78:1199-1207, 2017. (c) 2016 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:1199 / 1207
页数:9
相关论文
共 22 条
[21]   Motion-guided segmentation for cine DENSE MRI [J].
Spottiswoode, Bruce S. ;
Zhong, Xiaodong ;
Lorenz, Christine H. ;
Mayosi, Bongani M. ;
Meintjes, Ernesta M. ;
Epstein, Frederick H. .
MEDICAL IMAGE ANALYSIS, 2009, 13 (01) :105-115
[22]   Fourier tracking of myocardial motion using Cine-PC data [J].
Zhu, YD ;
Drangova, M ;
Pelc, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (04) :471-480