A semiautomatic method for rapid segmentation of velocity-encoded myocardial magnetic resonance imaging data

被引:10
作者
Espe, Emil K. S. [1 ,2 ]
Skardal, Kristine [1 ,2 ]
Aronsen, Jan Magnus [3 ]
Zhang, Lili [1 ,2 ]
Sjaastad, Ivar [1 ,2 ]
机构
[1] Oslo Univ Hosp, Inst Expt Med Res, Oslo, Norway
[2] Univ Oslo, Oslo, Norway
[3] Bjorknes Coll, Oslo, Norway
关键词
magnetic resonance imaging; MRI; tissue phase mapping; postprocessing; segmentation; phase contrast; PHASE-CONTRAST MRI; MOTION; TRACKING; QUANTIFICATION; HEART; DENSE;
D O I
10.1002/mrm.26486
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop a semiautomatic method for rapid segmentation of myocardial tissue phase mapping (TPM) data. MethodsManual segmentation of the myocardium was performed at end-diastole and end-systole. The points in both user-defined masks were then automatically tracked over the entire cardiac cycle using temporal integration of the velocity field. Paths that failed to visit both masks at the expected times were excluded, after which masks for all time points were generated automatically from the accepted paths. Midventricular and basal phase contrast TPM slices from 12 rats were segmented using the proposed method and fully manual segmentation. The results were compared using Dice's metric and Bland-Altman analysis, and interobserver variability was assessed. ResultsThe semiautomatic method reduced the average user input time from 21min to 1min per slice. The Dice metrics between the methods were 0.880.03 (midventricular) and 0.83 +/- 0.06 (basal), and Bland-Altman limits of agreement of peak systolic and diastolic regional velocities were: midventricular: 0.05 +/- 0.65cm/s, -0.02 +/- 0.42cm/s, and -0.03 +/- 0.40cm/s (radial, tangential, longitudinal); basal: -0.04 +/- 0.73cm/s, 0.03 +/- 0.60cm/s, and -0.04 +/- 0.48cm/s (radial, tangential, longitudinal). Interobserver variability following semiautomatic segmentation was lower than for manual segmentation. ConclusionThe proposed method reduced the segmentation time substantially and exhibited well-preserved data quality and excellent interobserver limits of agreement. Magn Reson Med 78:1199-1207, 2017. (c) 2016 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:1199 / 1207
页数:9
相关论文
共 22 条
[1]   DENSE: Displacement encoding with stimulated echoes in cardiac functional MRI [J].
Aletras, AH ;
Ding, SJ ;
Balaban, RS ;
Wen, H .
JOURNAL OF MAGNETIC RESONANCE, 1999, 137 (01) :247-252
[2]   Semi-automated left ventricular segmentation based on a guide point model approach for 3D cine DENSE cardiovascular magnetic resonance [J].
Auger, Daniel A. ;
Zhong, Xiaodong ;
Epstein, Frederick H. ;
Meintjes, Ernesta M. ;
Spottiswoode, Bruce S. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
[3]   A fast and highly automated approach to myocardial motion analysis using phase contrast magnetic resonance imaging [J].
Bergvall, E ;
Cain, P ;
Arheden, H ;
Sparr, G .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (05) :652-661
[4]   Spline-based cardiac motion tracking using velocity-encoded magnetic resonance imaging [J].
Bergvall, Erik ;
Hedstrom, Erik ;
Bloch, Karin Markenroth ;
Arheden, Hakan ;
Sparr, Gunnar .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (08) :1045-1053
[5]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[6]   Cardiac segmentation by a velocity-aided active contour model [J].
Cho, JS ;
Benkeser, PJ .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2006, 30 (01) :31-41
[7]   Details of left ventricular radial wall motion supporting the ventricular theory of the third heart sound obtained by cardiac MR [J].
Codreanu, I. ;
Robson, M. D. ;
Rider, O. J. ;
Pegg, T. J. ;
Dasanu, C. A. ;
Jung, B. A. ;
Rotaru, N. ;
Clarke, K. ;
Holloway, C. J. .
BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1037)
[8]   Improved method for quantification of regional cardiac function in mice using phase-contrast MRI [J].
Dall'Armellina, Erica ;
Jung, Bernd A. ;
Lygate, Craig A. ;
Neubauer, Stefan ;
Markl, Michael ;
Schneider, Juergen E. .
MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) :541-551
[9]  
Espe EK, 2015, CIRC-CARDIOVASC IMAG, P8
[10]   Unwrapping Eddy Current Compensation: Improved Compensation of Eddy Current Induced Baseline Shifts in High-Resolution Phase-Contrast MRI at 9.4 Tesla [J].
Espe, Emil K. S. ;
Zhang, Lili ;
Sjaastad, Ivar .
MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (04) :1096-1102