On a single-counts rate stabilization scheme employed in the imaging camera of the TACTIC γ-ray telescope

被引:14
作者
Bhatt, N [1 ]
Yadav, KK [1 ]
Kanda, A [1 ]
Koul, R [1 ]
Kaul, SR [1 ]
Goyal, HC [1 ]
Dhar, VK [1 ]
Kaul, SK [1 ]
Venugopal, K [1 ]
Tickoo, AK [1 ]
Kaul, IK [1 ]
Kothari, M [1 ]
Bhat, CL [1 ]
机构
[1] Bhabha Atom Res Ctr, Nucl Res Lab, Trombay 400085, Mumbai, India
关键词
single-counts rate; high voltage; photomultipliers; gamma-ray telescope; TACTIC; rate stabilization; gain calibration;
D O I
10.1088/0957-0233/12/2/307
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A cost-effective methodology for operating the 349-pixel Cerenkov light imaging camera of the imaging clement of the TACTIC gamma -ray telescope array at stable single-counts rate and safe anode current values has successfully been tried out despite variations in the light of the night sky experienced by these pixels from time to time. Important details of this unconventional scheme are discussed and reference is made to the methods evolved for in situ absolute and relative gain calibrations of the camera pixels, which air particularly required for this mode of operation.
引用
收藏
页码:167 / 171
页数:5
相关论文
共 9 条
[1]   The CAT imaging telescope for very-high-energy gamma-ray astronomy [J].
Barrau, A ;
Bazer-Bachi, R ;
Beyer, E ;
Cabot, H ;
Cerutti, M ;
Chounet, LM ;
Debiais, G ;
Degrange, B ;
Delchini, H ;
Denance, JP ;
Descotes, G ;
Dezalay, JP ;
Djannati-Atai, A ;
Dumora, D ;
Espigat, P ;
Fabre, B ;
Fleury, P ;
Fontaine, G ;
George, R ;
Ghesquiere, C ;
Gilly, J ;
Goret, P ;
Gouiffes, C ;
Gouillaud, JC ;
Gregory, C ;
Grenier, IA ;
Iacoucci, L ;
Kalt, L ;
Le Bohec, S ;
Malet, I ;
Meynadier, C ;
Mols, JP ;
de Freitas, PM ;
Morano, R ;
Morinaud, G ;
Munz, F ;
Palatka, M ;
Palfrey, TA ;
Pare, E ;
Pons, Y ;
Punch, M ;
Quebert, J ;
Ragan, K ;
Renault, C ;
Rivoal, M ;
Rob, L ;
Schovanek, P ;
Smith, D ;
Tabary, A ;
Tavernet, JP .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 416 (2-3) :278-292
[2]   Hybrid Zener-based VDN - A better choice for Cherenkov light imaging cameras [J].
Bhat, CL ;
Koul, R ;
Kaul, SR ;
Koul, SK ;
Kaul, I ;
Goyal, HC .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (04) :706-708
[3]  
BHAT CL, 1997, P WORKSH MAJ ATM CER, V5, P196
[4]  
Cawley M. F., 1990, Experimental Astronomy, V1, P173, DOI 10.1007/BF00462039
[5]   A 3.8 M IMAGING CHERENKOV TELESCOPE FOR THE TEV GAMMA-RAY ASTRONOMY COLLABORATION BETWEEN JAPAN AND AUSTRALIA [J].
HARA, T ;
KIFUNE, T ;
MATSUBARA, Y ;
MIZUMOTO, Y ;
MURAKI, Y ;
OGIO, S ;
SUDA, T ;
TANIMORI, T ;
TESHIMA, M ;
YOSHIKOSHI, T ;
EDWARDS, PG .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 332 (1-2) :300-309
[6]  
Konopelko A, 1996, ASTROPART PHYS, V4, P199, DOI 10.1016/0927-6505(95)00044-5
[7]  
MORZOYAN R, 1995, MAJOR ATMOSPHERIC CE, V4, P209
[8]   Drive-control system for the TACTIC gamma-ray telescope [J].
Tickoo, AK ;
Koul, R ;
Kaul, SK ;
Kaul, IK ;
Bhat, CL ;
Bhatt, NG ;
Kothari, MK ;
Goyal, HC ;
Agarwal, NK ;
Kaul, SR .
EXPERIMENTAL ASTRONOMY, 1999, 9 (02) :81-101
[9]  
1994, PHILIPS PHOTONICS PH, P4