Aortic root thrombosis in patients supported with continuous-flow left ventricular assist devices

被引:25
作者
Fried, Justin [1 ]
Garan, Arthur R. [1 ]
Shames, Sophia [1 ]
Masoumi, Amirali [1 ]
Yuzefpolskaya, Melana [1 ]
Takeda, Koji [2 ]
Takayama, Hiroo [2 ]
Uriel, Nir [3 ]
Naka, Yoshifumi [2 ]
Colombo, Paolo C. [1 ]
Topkara, Veli K. [1 ]
机构
[1] Columbia Univ, Dept Med, Div Cardiol, Med Ctr,New York Presbyterian Hosp, New York, NY USA
[2] Columbia Univ, Div Cardiothorac Surg, Dept Surg, Med Ctr,New York Presbyterian Hosp, New York, NY USA
[3] Univ Chicago, Dept Med, Div Cardiol, 5841 S Maryland Ave, Chicago, IL 60637 USA
基金
美国国家卫生研究院;
关键词
IMPLANTATION;
D O I
10.1016/j.healun.2018.07.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Aortic root thrombosis (ART) is a recently recognized complication of continuous-flow left ventricular assist device (CF-LVAD) therapy. However, little is known about the prevalence or clinical significance of this complication. The aim of our study was to systematically evaluate the incidence and significance of ART on CF-LVAD support. METHODS: We retrospectively reviewed all patients who underwent HeartMate II or HeartWare HVAD CF-LVAD implantation from April 2004 through June 2016 at the Columbia University Medical Center. Echocardiography studies were systematically reviewed to identify patients who developed ART. Study outcomes included post-ART survival on CF-LVAD support, stroke, pump thrombosis, and clinically significant myocardial infarction (MI). RESULTS: The study cohort consisted of 436 CF-LVAD patients with 21 patients (4.8%) diagnosed with confirmed ART at a median time of 22 days (interquartile range [IQR] 3 to 56 days) after CF-LVAD implantation. Involvement of the non-coronary cusp was the most common location of the ART (n=15, 71.4%) and concomitant RV failure occurred in 14 patients (66.7%). Actuarial survival at 1 and 2 years after diagnosis of ART was 73.8% and 44.3%, respectively. ART was associated with a high rate of complications, including stroke (28.6%, 0.337 episode per patient-year [EPPY]) and clinically significant MI (28.6%, 0.337 EPPY). CONCLUSIONS: ART is not uncommon after CF-LVAD implantation and is associated with significant morbidity and mortality in CF-LVAD patients. Given the early occurrence and high incidence of stroke and MI in patients who develop ART, surveillance and treatment strategies should be implemented to address this potentially devastating complication. (C) 2018 International Society for Heart and Lung Transplantation. All rights reserved.
引用
收藏
页码:1425 / 1432
页数:8
相关论文
共 11 条
[1]   Aortic Valve Thrombus in a Patient With an Extracorporeal Left Ventricular Assist Device: The Dilemma of Management [J].
Barrick, Brian P. ;
Smeltz, Alan ;
Ganesh, Arun ;
Arora, Harendra ;
Kumar, Priya A. .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2016, 30 (01) :196-199
[2]   Computational fluid dynamic study of hemodynamic effects on aortic root blood flow of systematically varied left ventricular assist device graft anastomosis design [J].
Callington, Andrew ;
Long, Quan ;
Mohite, Prashant ;
Simon, Andre ;
Mittal, Tarun Kumar .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 150 (03) :696-704
[3]  
Crestanello Juan A, 2009, Interact Cardiovasc Thorac Surg, V8, P661, DOI 10.1510/icvts.2009.202242
[4]  
Demirozu ZT, 2012, TEX HEART I J, V39, P618
[5]   Myocardial infarction after left ventricular assist device implantation: Clinical course, role of aortic root thrombus, and outcomes [J].
Fried, Justin ;
Han, Jason ;
Naka, Yoshifumi ;
Jorde, Ulrich P. ;
Uriel, Nir .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (01) :112-115
[6]   Readmissions After Implantation of Axial Flow Left Ventricular Assist Device [J].
Hasin, Tal ;
Marmor, Yariv ;
Kremers, Walter ;
Topilsky, Yan ;
Severson, Cathy J. ;
Schirger, John A. ;
Boilson, Barry A. ;
Clavell, Alfredo L. ;
Rodeheffer, Richard J. ;
Frantz, Robert P. ;
Edwards, Brooks S. ;
Pereira, Naveen L. ;
Stulak, John M. ;
Joyce, Lyle ;
Daly, Richard ;
Park, Soon J. ;
Kushwaha, Sudhir S. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (02) :153-163
[7]   Watchful Waiting in Continuous-Flow Left Ventricular Assist Device Patients With Ongoing Hemolysis Is Associated With an Increased Risk for Cerebrovascular Accident or Death [J].
Levin, Allison P. ;
Saeed, Omar ;
Willey, Joshua Z. ;
Levin, Charles J. ;
Fried, Justin A. ;
Patel, Snehal R. ;
Sims, Daniel B. ;
Nguyen, Jenni D. ;
Shin, Julia J. ;
Topkara, Veli K. ;
Colombo, Paolo C. ;
Goldstein, Daniel J. ;
Naka, Yoshifumi ;
Takayama, Hiroo ;
Uriel, Nir ;
Jorde, Ulrich P. .
CIRCULATION-HEART FAILURE, 2016, 9 (05)
[8]   Two-Year Outcomes with a Magnetically Levitated Cardiac Pump in Heart Failure [J].
Mehra, M. R. ;
Goldstein, D. J. ;
Uriel, N. ;
Cleveland, J. C. ;
Yuzefpolskaya, M. ;
Salerno, C. ;
Walsh, M. N. ;
Milano, C. A. ;
Patel, C. B. ;
Ewald, G. A. ;
Itoh, A. ;
Dean, D. ;
Krishnamoorthy, A. ;
Cotts, W. G. ;
Tatooles, A. J. ;
Jorde, U. P. ;
Bruckner, B. A. ;
Estep, J. D. ;
Jeevanandam, V. ;
Sayer, G. ;
Horstmanshof, D. ;
Long, J. W. ;
Gulati, S. ;
Skipper, E. R. ;
O'Connell, J. B. ;
Heatley, G. ;
Sood, P. ;
Naka, Y. .
NEW ENGLAND JOURNAL OF MEDICINE, 2018, 378 (15) :1386-1395
[9]   Evaluation of low-intensity anti-coagulation with a fully magnetically levitated centrifugal-flow circulatory pump-the MAGENTUM 1 study [J].
Netuka, Ivan ;
Ivak, Peter ;
Tucanova, Zuzana ;
Gregor, Stanislav ;
Szarszoi, Ondrej ;
Sood, Poornima ;
Crandall, Daniel ;
Rimsans, Jessica ;
Connors, Jean Marie ;
Mehra, Mandeep R. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (05) :579-586
[10]   Intrapericardial Left Ventricular Assist Device for Advanced Heart Failure [J].
Rogers, Joseph G. ;
Pagani, Francis D. ;
Tatooles, Antone J. ;
Bhat, Geetha ;
Slaughter, Mark S. ;
Birks, Emma J. ;
Boyce, Steven W. ;
Najjar, Samer S. ;
Jeevanandam, Valluvan ;
Anderson, Allen S. ;
Gregoric, Igor D. ;
Mallidi, Hari ;
Leadley, Katrin ;
Aaronson, Keith D. ;
Frazier, O. H. ;
Milano, Carmelo A. .
NEW ENGLAND JOURNAL OF MEDICINE, 2017, 376 (05) :451-460