Evaluation of High-Pitch Ungated Pediatric Cardiovascular Computed Tomography for the Assessment of Cardiac Structures in Neonates

被引:13
作者
Sriharan, Mona [1 ]
Lazoura, Olga [1 ]
Pavitt, Christopher W. [1 ,2 ,4 ]
Castellano, Isabel [3 ]
Owens, Catherine M.
Rubens, Michael B. [1 ,5 ]
Padley, Simon P. G. [1 ,5 ]
Nicol, Edward D. [1 ,2 ,5 ]
机构
[1] Royal Brompton Hosp, Dept Radiol, Sydney St, London SW3 6NP, England
[2] Royal Brompton Hosp, Dept Cardiol, Sydney St, London SW3 6NP, England
[3] Royal Marsden, Joint Dept Phys, Fulham Rd, London, England
[4] Great Ormond St Hosp Sick Children, Dept Radiol, Great Ormond St, London WC1N 3JH, England
[5] Univ London Imperial Coll Sci Technol & Med, Fac Med, Natl Heart & Lung Inst, London, England
关键词
multidetector computed tomography; radiation dose; pediatric cardiac computed tomography; CONGENITAL HEART-DISEASE; DUAL-SOURCE CT; MULTIDETECTOR-ROW CT; IMAGE QUALITY; SPIRAL CT; CHILDREN; ANGIOGRAPHY; DIAGNOSIS; ARTERIES; INFANTS;
D O I
10.1097/RTI.0000000000000201
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We evaluated a high-pitch, non-electrocardiogram-gated cardiac computed tomographic protocol, designed to image both cardiac and extracardiac structures, including coronary arteries, in a neonatal population (less than 1 year old) that was referred for congenital heart disease assessment and compared it with an optimized standard-pitch protocol in an equivalent cohort. Materials and Methods: Twenty-nine high-pitch scans were compared with 31 age-matched, sex-matched, and weight-matched standard-pitch, dosimetrically equivalent scans. The visualization and subjective quality of both cardiac and extracardiac structures were scored by consensus between 2 trained blinded observers. Image noise, signal-to-noise and contrast-to-noise ratios, and radiation doses were also compared. Results: The high-pitch protocol better demonstrated the pulmonary veins (P = 0.03) and all coronary segments (all P < 0.05), except the distal right coronary artery (P = 0.10), with no significant difference in the visualization of the remaining cardiac or extracardiac structures. Both contrast-to-noise and signal-to-noise ratios improved due to greater vessel opacity, with significantly fewer streak (P < 0.01) and motion (P < 0.01) artifacts. Image noise and computed tomographic dose index were comparable across the 2 techniques; however, the high-pitch acquisition resulted in a small, but statistically significant, increase in dose-length product [13.0 mGy.cm (9.0 to 17.3) vs. 11.0 mGy.cm (9.0 to 13.0), P = 0.05] due to greater z-overscanning. Conclusions: In neonates, a high-pitch protocol improves coronary artery and pulmonary vein delineation compared with the standard-pitch protocol, allowing a more comprehensive assessment of cardiovascular anatomy while obviating the need for either patient sedation or heart rate control.
引用
收藏
页码:177 / 182
页数:6
相关论文
共 26 条
[1]  
Austen W G, 1975, Circulation, V51, P5
[2]   Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience [J].
Cheng, Zhaoping ;
Wang, Ximing ;
Duan, Yanhua ;
Wu, Lebin ;
Wu, Dawei ;
Chao, Baoting ;
Liu, Cheng ;
Xu, Zhuodong ;
Li, Hongxin ;
Liang, Fei ;
Xu, Jian ;
Chen, Jiuhong .
EUROPEAN RADIOLOGY, 2010, 20 (10) :2503-2511
[3]   Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality [J].
Flohr, Thomas G. ;
Leng, Shuai ;
Yu, Lifeng ;
Allmendinger, Thomas ;
Bruder, Herbert ;
Petersilka, Martin ;
Eusemann, Christian D. ;
Stierstorfer, Karl ;
Schmidt, Bernhard ;
McCollough, Cynthia H. .
MEDICAL PHYSICS, 2009, 36 (12) :5641-5653
[4]   Image Quality in Reduced-Dose Coronary CT Angiography [J].
Gagarina, Nina V. ;
Irwan, Roy ;
Gordina, Galina ;
Fominykh, Ekaterina ;
Sijens, Paul E. .
ACADEMIC RADIOLOGY, 2011, 18 (08) :984-990
[5]   Low dose dual-source CT angiography in infants with complex congenital heart disease: A randomized study [J].
Gao, Yang ;
Lu, Bin ;
Hou, Zhihui ;
Yu, Fangfang ;
Cao, Huili ;
Han, Lei ;
Wu, Runze .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (07) :E789-E795
[6]   Computed tomography for the diagnosis of congenital heart disease in pediatric and adult patients [J].
Goo, HW ;
Park, IS ;
Ko, JK ;
Kim, YH ;
Seo, DM ;
Park, JJ .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (2-3) :347-365
[7]   Accuracy and Safety of High Pitch Computed Tomography Imaging in Young Children With Complex Congenital Heart Disease [J].
Han, B. Kelly ;
Lindberg, Jana ;
Grant, Katharine ;
Schwartz, Robert S. ;
Lesser, John R. .
AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (10) :1541-1546
[8]   The neonate with congenital heart disease: What the cardiac surgeon needs to know from the neonatologist and the cardiologist [J].
Jaquiss, RDB ;
Tweddell, JS .
CLINICS IN PERINATOLOGY, 2005, 32 (04) :947-+
[9]   64-slice multidetector-row computed tomographic angiography for evaluating congenital heart disease [J].
Khatri, Sanjay ;
Varma, Suraj Kumar ;
Khatri, Payal ;
Kumar, Raghavannair Suresh .
PEDIATRIC CARDIOLOGY, 2008, 29 (04) :755-762
[10]   Using multidetector-row CT in neonates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: initial experiences in technical and clinical feasibility [J].
Lee, Tain ;
Tsai, I-Chen ;
Fu, Yun-Ching ;
Jan, Sheng-Lin ;
Wang, Chung-Chi ;
Chang, Yen ;
Chen, Min-Chi .
PEDIATRIC RADIOLOGY, 2006, 36 (12) :1273-1282