Comparison of Hydrus and iStent microinvasive glaucoma surgery implants in combination with phacoemulsification for treatment of open-angle glaucoma: systematic review and network meta-analysis

被引:11
|
作者
Hu, Rongrong [1 ]
Guo, Dongyu [1 ]
Hong, Nan [1 ]
Xuan, Xiuyuan [1 ]
Wang, Xiaoyu [1 ]
机构
[1] Zhejiang Univ, Dept Ophthalmol, Affiliated Hosp 1, Sch Med, Hangzhou, Zhejiang, Peoples R China
来源
BMJ OPEN | 2022年 / 12卷 / 06期
基金
中国国家自然科学基金;
关键词
Glaucoma; Cataract and refractive surgery; Ophthalmology; TRABECULAR BYPASS STENTS; MINIMALLY INVASIVE GLAUCOMA; INTRAOCULAR-PRESSURE; OUTFLOW FACILITY; CATARACT-SURGERY; MICROBYPASS STENT; QUALITY; RELIABILITY; TRIALS;
D O I
10.1136/bmjopen-2021-051496
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives To compare the efficacy and safety of two Schlemm's canal-based microinvasive glaucoma surgery (MIGS) devices, the Hydrus Microstent and the iStent Trabecular Bypass combined with phacoemulsification for treatment of open-angle glaucoma. Design Systematic review and network meta-analysis. Methods Literature searches were conducted on PubMed, Web of Science, Cochrane Library and ClinicalTrials.gov to identify randomised controlled trials (RCTs) assessing the Hydrus or the iStent implantation combined with phacoemulsification for treatment of open-angle glaucoma until September 2020. Risk of bias was assessed using a six-item modified Jadad scale. Effects were estimated using the intraocular pressure (IOP) reduction (IOPR), the percentage of IOPR and the proportion of medication-free patients at follow-up end. Safety was estimated using the proportions of adverse events. The network meta-analysis was conducted within a Bayesian framework using the Markov Chain Monte Carlo method in ADDIS software. Results Six prospective RCTs comprising 1397 patients were identified. Regarding the absolute value and the percentage of IOPR, the Hydrus and 2-iStent implantation combined with phacoemulsification were significantly more effective than phacoemulsification alone. Rank probability analysis revealed the Hydrus might be the best choice to lower IOP. There was no significant difference in the proportion of medication-free patients among groups. The Hydrus and 2-iStent implantation had a higher probability to achieve the medication-free status versus the 1-iStent implantation and phacoemulsification alone. Overall safety profiles were good for each device with the focal peripheral anterior synechiae more frequently reported in Hydrus eyes. Conclusions The Hydrus implantation may have a slight advantage over the 1-iStent or 2-iStent implantation in combination with phacoemulsification to treat open-angle glaucoma. Our findings might be of some uncertainty due to the limited included data. Further studies are needed to investigate whether our findings are robust, including high-quality RCTs to directly compare these MIGS devices.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Primary Open Angle Glaucoma Prevalence in Europe: A Systematic Review and Meta-Analysis
    Afflitto, Gabriele Gallo
    Aiello, Francesco
    Cesareo, Massimo
    Nucci, Carlo
    JOURNAL OF GLAUCOMA, 2022, 31 (10) : 783 - 788
  • [42] Latanoprostene Bunod 0.024% in the Treatment of Open-Angle Glaucoma and Ocular Hypertension: A Meta-Analysis
    Lo, Tzu-Chen
    Chen, Yu-Yen
    Hung, Man-Chen
    Chou, Pesus
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (15)
  • [43] A cost-effectiveness analysis of iStent inject combined with phacoemulsification cataract surgery in patients with mild-to-moderate open-angle glaucoma in France
    Nieland, Kaspar
    Labbe, Antoine
    Schweitzer, Cedric
    Gicquel, Gaetan
    Kleintjens, Joris
    Ostawal, Amrita
    Treur, Maarten
    Falvey, Heather
    PLOS ONE, 2021, 16 (06):
  • [44] Comparison of surgical outcomes between iStent inject W implantation and microhook ab interno trabeculotomy in combination with phacoemulsification in primary open-angle glaucoma patients
    Onoe, Hiromitsu
    Hirooka, Kazuyuki
    Namiguchi, Koji
    Mizoue, Shiro
    Hosokawa, Hiroko
    Mochizuki, Hideki
    Okada, Naoki
    Tokumo, Kana
    Okumichi, Hideaki
    Kiuchi, Yoshiaki
    FRONTIERS IN MEDICINE, 2023, 10
  • [45] The Association of Blood Pressure and Primary Open-Angle Glaucoma: A Meta-analysis
    Zhao, Di
    Cho, Juhee
    Kim, Myung Hun
    Guallar, Eliseo
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (03) : 615 - 627
  • [46] Combined Endoscopic Cyclophotocoagulation and Phacoemulsification Versus Phacoemulsification Alone in the Glaucoma Treatment: A Systematic Review and Meta-Analysis
    Amaral, Dillan Cunha
    Louzada, Ricardo Noguera
    Moreira, Pedro Henrique Santana
    de Oliveira, Lucas Neves
    Yuati, Thais Tiemi
    Guedes, Jaime
    Alves, Milton Ruiz
    Mora-Paez, Denisse Josefina
    Monteiro, Mario Luiz Ribeiro
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)
  • [47] Corneal Biomechanics in Primary Open Angle Glaucoma and Ocular Hypertension: A Systematic Review and Meta-analysis
    Liu, Min-Xin
    Zhou, Miao
    Li, Dan-Lin
    Dong, Xing-Xuan
    Liang, Gang
    Pan, Chen-Wei
    JOURNAL OF GLAUCOMA, 2023, 32 (03) : E24 - E32
  • [48] Association of MYOC and APOE promoter polymorphisms and primary open-angle glaucoma: a meta-analysis
    Guo, Hui
    Li, Minghao
    Wang, Zhe
    Liu, Qiji
    Wu, Xinyi
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (02): : 2052 - 2064
  • [49] Systematic Literature Review of Clinical and Economic Outcomes of Micro-Invasive Glaucoma Surgery (MIGS) in Primary Open-Angle Glaucoma
    Agrawal, Pavi
    Bradshaw, Steven E.
    OPHTHALMOLOGY AND THERAPY, 2018, 7 (01) : 49 - 73
  • [50] Comparison of canaloplasty and trabeculectomy for open angle glaucoma: a Meta-analysis
    Lin, Zhong-Jing
    Xu, Shuo
    Huang, Shou-Yue
    Zhang, Xiao-Bin
    Zhong, Yi-Sheng
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (12) : 1814 - 1819