Amperometric detection of hydrogen peroxide at a Prussian Blue-modified FTO electrode

被引:65
|
作者
Tseng, KS
Chen, LC
Ho, KC [1 ]
机构
[1] Natl Taiwan Univ, Dept Chem Engn, Taipei 10617, Taiwan
[2] Natl Taiwan Univ, Inst Polymer Sci & Engn, Taipei 10617, Taiwan
关键词
FTO; hydrogen peroxide; modified electrode; Prussian blue; H2O2; sensor;
D O I
10.1016/j.snb.2004.12.031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This research focuses on the use of a Prussian Blue (PB)-modified optically transparent electrode for sensing hydrogen peroxide (H2O2). The PB thin films were deposited galvanostatically onto F-doped tin oxide (FTO) glass substrates. Then a reliable and reproducible detection was achieved by exerting a constant bias of -0.2 V (versus Ag/AgCl/saturated KCl) at the PB-modified FTO electrode immersed in an H2O2 solution containing 0.1 M KCl, pH 2. The dynamic range of detection was found to lie between 50 mu M and 50 mM, and the sensitivity was ca. 58.1 mA/cm(2) M. But it was also observed that the dissolved oxygen interfered the H2O2 sensing. Better sensing results could be obtained if the solution was pre-purged with N-2. To sum up, this study possesses the potential to eliminate the use of costly platinum or glassy carbon in a PB-based H2O2 sensor and may provide the basis for optical sensing. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:738 / 745
页数:8
相关论文
共 50 条
  • [31] A Prussian blue-based amperometric sensor for the determination of hydrogen peroxide residues in milk
    Ping, Jianfeng
    Mao, Xiuling
    Fan, Kai
    Li, Dongyang
    Ru, Shiping
    Wu, Jian
    Ying, Yibin
    IONICS, 2010, 16 (06) : 523 - 527
  • [32] Electrocatalytic oxidation of hydrazine at a Prussian Blue-modified glassy carbon electrode
    Scharf, U
    Grabner, EW
    ELECTROCHIMICA ACTA, 1996, 41 (02) : 233 - 239
  • [33] Behavior of PQQ glucose dehydrogenase on Prussian blue-modified carbon electrode
    Laurinavicius, Valdas
    Kurtinaitiene, Bogumila
    Stankeviciute, Rasa
    ELECTROANALYSIS, 2008, 20 (13) : 1391 - 1395
  • [34] Amperometric choline biosensors prepared by layer-by-layer deposition of choline oxidase on the Prussian blue-modified platinum electrode
    Shi, Haibin
    Yang, Yu
    Huang, Jiadong
    Zhao, Zixia
    Xu, Xinhua
    Anzai, Jun-ichi
    Osa, Tetsuo
    Chen, Qiang
    TALANTA, 2006, 70 (04) : 852 - 858
  • [35] Rhodium stabilized Prussian Blue-modified graphite electrodes for H2O2 amperometric detection
    Muresan, Laura
    Turdean, Graziella Liana
    Popescu, Ionel Catalin
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2008, 38 (03) : 349 - 355
  • [36] Non-enzyme Sensor for Hydrogen Peroxide Based on Prussian Blue/Manganese Dioxide Composite Modified Electrode
    Liu Yu-Ge
    Li Zhi-Guo
    Chen Wei-Zhen
    CHINESE JOURNAL OF INORGANIC CHEMISTRY, 2020, 36 (03) : 421 - 425
  • [37] Electrocatalytic reduction of hydrogen peroxide at Prussian blue modified electrode: An in situ Raman spectroelectrochemical study
    Mazeikiene, Regina
    Niaura, Gediminas
    Malinauskas, Albertas
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 660 (01) : 140 - 146
  • [38] Amphiphilic dendrimer loaded prussian blue nanoparticle for the detection of hydrogen peroxide
    Pakrudheen, Iqbal
    Bathinapatla, Ayyappa
    Murugan, Eagambaram
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2022, 29 (06) : 668 - 677
  • [39] Rhodium stabilized Prussian Blue-modified graphite electrodes for H2O2 amperometric detection
    Laura Mureşan
    Graziella Liana Turdean
    Ionel Cătălin Popescu
    Journal of Applied Electrochemistry, 2008, 38 : 349 - 355
  • [40] A novel and improved surfactant-modified Prussian Blue electrode for amperometric detection of free chlorine in water
    Salazar, Pedro
    Martin, Miriam
    Garcia-Garcia, Francisco J.
    Luis Gonzalez-Mora, Jose
    Gonzalez-Elipe, Agustin R.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 213 : 116 - 123