Amperometric detection of hydrogen peroxide at a Prussian Blue-modified FTO electrode

被引:65
|
作者
Tseng, KS
Chen, LC
Ho, KC [1 ]
机构
[1] Natl Taiwan Univ, Dept Chem Engn, Taipei 10617, Taiwan
[2] Natl Taiwan Univ, Inst Polymer Sci & Engn, Taipei 10617, Taiwan
关键词
FTO; hydrogen peroxide; modified electrode; Prussian blue; H2O2; sensor;
D O I
10.1016/j.snb.2004.12.031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This research focuses on the use of a Prussian Blue (PB)-modified optically transparent electrode for sensing hydrogen peroxide (H2O2). The PB thin films were deposited galvanostatically onto F-doped tin oxide (FTO) glass substrates. Then a reliable and reproducible detection was achieved by exerting a constant bias of -0.2 V (versus Ag/AgCl/saturated KCl) at the PB-modified FTO electrode immersed in an H2O2 solution containing 0.1 M KCl, pH 2. The dynamic range of detection was found to lie between 50 mu M and 50 mM, and the sensitivity was ca. 58.1 mA/cm(2) M. But it was also observed that the dissolved oxygen interfered the H2O2 sensing. Better sensing results could be obtained if the solution was pre-purged with N-2. To sum up, this study possesses the potential to eliminate the use of costly platinum or glassy carbon in a PB-based H2O2 sensor and may provide the basis for optical sensing. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:738 / 745
页数:8
相关论文
共 50 条
  • [21] An amperometric biosensor using Prussian blue modified electrode
    Yi, In-Je
    Kim, Ju-Ho
    Kang, C. J.
    Park, Jaehyun
    Kim, Yong-Sang
    ECO-MATERIALS PROCESSING & DESIGN VII, 2006, 510-511 : 746 - 749
  • [22] Behavior of PQQ glucose dehydrogenase on Prussian blue-modified carbon electrode
    Laurinavicius, Valdas
    Kurtinaitiene, Bogumila
    Stankeviciute, Rasa
    ELECTROANALYSIS, 2008, 20 (13) : 1391 - 1395
  • [23] Amperometric choline biosensors prepared by layer-by-layer deposition of choline oxidase on the Prussian blue-modified platinum electrode
    Shi, Haibin
    Yang, Yu
    Huang, Jiadong
    Zhao, Zixia
    Xu, Xinhua
    Anzai, Jun-ichi
    Osa, Tetsuo
    Chen, Qiang
    TALANTA, 2006, 70 (04) : 852 - 858
  • [24] Determination of hydrogen peroxide using a Prussian Blue modified macroporous gold electrode
    Jiao Yang
    Meng Lin
    MiSuk Cho
    Youngkwan Lee
    Microchimica Acta, 2015, 182 : 1089 - 1094
  • [25] Determination of hydrogen peroxide using a Prussian Blue modified macroporous gold electrode
    Yang, Jiao
    Lin, Meng
    Cho, MiSuk
    Lee, Youngkwan
    MICROCHIMICA ACTA, 2015, 182 (5-6) : 1089 - 1094
  • [26] A HYDROGEN PEROXIDE SENSOR BASED ON PRUSSIAN BLUE AND DNA-MODIFIED ELECTRODE
    Ma, Xiuju
    Yin, Guang
    Yang, Xiao
    Wan, Jun
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2013, 41 (05) : 490 - 499
  • [27] Electrochemical Detection of Hydrogen Peroxide Based on Graphene Oxide/Prussian Blue Modified Glassy Carbon Electrode
    Farah, Abdullahi Mohamed
    Thema, Force Tefo
    Dikio, Ezekiel Dixon
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (06): : 5069 - 5083
  • [28] Rhodium stabilized Prussian Blue-modified graphite electrodes for H2O2 amperometric detection
    Muresan, Laura
    Turdean, Graziella Liana
    Popescu, Ionel Catalin
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2008, 38 (03) : 349 - 355
  • [29] Uptake and Electrochemical Ejection of Cesium Ion by a Prussian Blue-modified Electrode
    Tatsuma, Tetsu
    Kuroiwa, Yoshinori
    Ishii, Kazuyuki
    Kudo, Kazuaki
    Sakoda, Akiyoshi
    CHEMISTRY LETTERS, 2014, 43 (08) : 1281 - 1283
  • [30] Rhodium stabilized Prussian Blue-modified graphite electrodes for H2O2 amperometric detection
    Laura Mureşan
    Graziella Liana Turdean
    Ionel Cătălin Popescu
    Journal of Applied Electrochemistry, 2008, 38 : 349 - 355