Amperometric detection of hydrogen peroxide at a Prussian Blue-modified FTO electrode

被引:65
|
作者
Tseng, KS
Chen, LC
Ho, KC [1 ]
机构
[1] Natl Taiwan Univ, Dept Chem Engn, Taipei 10617, Taiwan
[2] Natl Taiwan Univ, Inst Polymer Sci & Engn, Taipei 10617, Taiwan
关键词
FTO; hydrogen peroxide; modified electrode; Prussian blue; H2O2; sensor;
D O I
10.1016/j.snb.2004.12.031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This research focuses on the use of a Prussian Blue (PB)-modified optically transparent electrode for sensing hydrogen peroxide (H2O2). The PB thin films were deposited galvanostatically onto F-doped tin oxide (FTO) glass substrates. Then a reliable and reproducible detection was achieved by exerting a constant bias of -0.2 V (versus Ag/AgCl/saturated KCl) at the PB-modified FTO electrode immersed in an H2O2 solution containing 0.1 M KCl, pH 2. The dynamic range of detection was found to lie between 50 mu M and 50 mM, and the sensitivity was ca. 58.1 mA/cm(2) M. But it was also observed that the dissolved oxygen interfered the H2O2 sensing. Better sensing results could be obtained if the solution was pre-purged with N-2. To sum up, this study possesses the potential to eliminate the use of costly platinum or glassy carbon in a PB-based H2O2 sensor and may provide the basis for optical sensing. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:738 / 745
页数:8
相关论文
共 50 条
  • [21] Determination of hydrogen peroxide using a Prussian Blue modified macroporous gold electrode
    Jiao Yang
    Meng Lin
    MiSuk Cho
    Youngkwan Lee
    Microchimica Acta, 2015, 182 : 1089 - 1094
  • [22] Electrochemical Detection of Hydrogen Peroxide Based on Graphene Oxide/Prussian Blue Modified Glassy Carbon Electrode
    Farah, Abdullahi Mohamed
    Thema, Force Tefo
    Dikio, Ezekiel Dixon
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (06): : 5069 - 5083
  • [23] A sensitivity-controlled hydrogen peroxide sensor based on self-assembled Prussian Blue modified electrode
    Liu, Yu
    Chu, Zhenyu
    Jin, Wanqin
    ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (02) : 484 - 487
  • [24] Determination of hydrogen peroxide using a Prussian Blue modified macroporous gold electrode
    Yang, Jiao
    Lin, Meng
    Cho, MiSuk
    Lee, Youngkwan
    MICROCHIMICA ACTA, 2015, 182 (5-6) : 1089 - 1094
  • [25] Acetylcholinesterase biosensor based on prussian blue-modified electrode for detecting organophosphorous pesticides
    Sun, Xia
    Wang, Xiangyou
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (12) : 2611 - 2614
  • [26] Dependence of redox characteristics in Prussian blue-modified electrode on pH of electrolytic solution
    Toyoda, Y
    Katoh, N
    Kuwabara, K
    MATERIALS SCIENCE AND ENGINEERING B-SOLID STATE MATERIALS FOR ADVANCED TECHNOLOGY, 2004, 108 (03): : 271 - 277
  • [27] Fabrication of Prussian Blue/Multi-Walled Carbon Nanotubes Modified Glassy Carbon Electrode for Electrochemical Detection of Hydrogen Peroxide
    Farah, Abdullahi Mohamed
    Shooto, Ntaote David
    Thema, Force Tefo
    Modise, Johannes Sekomeng
    Dikio, Ezekiel Dixon
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (05): : 4302 - 4313
  • [28] Amperometric biosensor based on Prussian Blue-modified screen-printed electrode for lipase activity and triacylglycerol determination
    Rejeb, Ines Ben
    Arduini, Fabiana
    Amine, Aziz
    Gargouri, Mohamed
    Palleschi, Giuseppe
    ANALYTICA CHIMICA ACTA, 2007, 594 (01) : 1 - 8
  • [29] An amperometric sensor based on Prussian blue and poly(o-phenylenediamine) modified glassy carbon electrode for the determination of hydrogen peroxide in beverages
    Ping, Jianfeng
    Wu, Jian
    Fan, Kai
    Ying, Yibin
    FOOD CHEMISTRY, 2011, 126 (04) : 2005 - 2009
  • [30] An amperometric biosensor using Prussian blue modified electrode
    Yi, In-Je
    Kim, Ju-Ho
    Kang, C. J.
    Park, Jaehyun
    Kim, Yong-Sang
    ECO-MATERIALS PROCESSING & DESIGN VII, 2006, 510-511 : 746 - 749