Evaluation of Chromium and Manganese levels in sports supplements using graphite furnace atomic absorption spectrometry

被引:2
作者
Lisboa, Thalles Pedrosa [1 ]
Flores, Leona da Silva [2 ]
Correa, Charlane Cimini [2 ]
de Sousa, Rafael Arromba [1 ]
机构
[1] Univ Fed Juiz de Fora, Dept Quim, Grp Baccan Quim Analit, R Jose Lourenco Kelmer S-N,Campus Univ, BR-36036900 Juiz De Fora, MG, Brazil
[2] Univ Fed Juiz de Fora, Dept Quim, Grp Pesquisa Quim Mat Porosos, Juiz De Fora, MG, Brazil
来源
REVISTA DE NUTRICAO-BRAZILIAN JOURNAL OF NUTRITION | 2020年 / 33卷
关键词
Atomic absorption; Chromium; Manganese; Micronutrients; Supplements; X-ray diffraction; DIETARY-SUPPLEMENTS; INFANT FORMULAS; QUALITY-CONTROL; ELEMENTS; SAMPLES; CR; CU; MICROEXTRACTION; SPECIATION; CADMIUM;
D O I
10.1590/1678-9865202033e190141
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Objective In this paper, we studied three different types of ordinary sports supplements containing whey protein: whey protein-based ones, hypercaloric ones, and protein bars. Methods A sample preparation procedure was studied employing microwave-assisted wet digestion in order to determine the Chromium and Manganese levels by graphite furnace atomic absorption spectrometry. Results The developed methods have presented good accuracy (recoveries in the range of 90% to 109%) and precision (Relative standard deviation <8%). Although an adequate detectability was obtained (50ng g(-1) for Manganese and 65ng g(-1) for Chromium), the sample preparation method was also adequate to inductively coupled plasma mass spectrometry analysis. The method was applied to 26 commercial samples, in which the Chromium concentrations were in the range between 0.22 and 1.0 mu g g(-1) and the Manganese concentrations varied from 2.0 to 37 mu g g(-1). Conclusion The results obtained by atomic absorption for both analytes were in agreement with those obtained by mass spectrometry. In addition, some samples presented concentrations of Chromium above the recommended daily intake and, as a result, we used the X-ray powder diffraction technique as an analytical tool to evaluate the oxidation state of Chromium in such samples.
引用
收藏
页数:13
相关论文
共 50 条
[41]   Direct and Simultaneous Determination of Cd Cu, and Se in Blood Samples by Graphite Furnace Atomic Absorption Spectrometry [J].
Caldas, Naise Mary ;
Raposo, Jorge Luiz, Jr. ;
Oliveira, Silvana Ruella ;
Gomes Neto, Jose Anchieta ;
Barbosa, Fernando, Jr. .
ATOMIC SPECTROSCOPY, 2009, 30 (04) :115-119
[42]   EVALUATION OF DIFFERENT METHODS FOR COPPER DETERMINATION IN INSULATING OILS BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY [J].
Caldas, Luiz Fernando S. ;
de Paula, Carlos Eduardo R. ;
Brum, Daniel M. ;
Lepri, Fabio G. ;
Cassella, Ricardo J. .
QUIMICA NOVA, 2014, 37 (05) :776-782
[43]   DETERMINATION OF TRACE AMOUNTS OF IRON AND CHROMIUM IN ALUMINUM NITRIDE BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
SHIMADA, Y ;
OHASHI, H ;
HARIMAYA, S .
TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1991, 77 (11) :1922-1928
[44]   PHYSIOLOGICAL CHROMIUM DETERMINATION IN SERUM BY ZEEMAN GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY - A SERIOUS CHALLENGE [J].
CHAPPUIS, P ;
POUPON, J ;
DESCHAMPS, JF ;
GUILLAUSSEAU, PJ ;
ROUSSELET, F .
BIOLOGICAL TRACE ELEMENT RESEARCH, 1992, 32 :85-91
[45]   Multivariate Approach in the Optimization Procedures for the Direct Determination of Manganese in Serum Samples by Graphite Furnace Atomic Absorption Spectrometry [J].
Ferraz Fabrino, Henrique Jose ;
Silveira, Josianne Nicacio ;
Borges Neto, Waldomiro ;
Goes, Alfredo Miranda ;
Beinner, Mark Anthony ;
Borba da Silva, Jose Bento .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2011, 35 (08) :571-576
[46]   Development of a method to determine Ni and Cd in biodiesel by graphite furnace atomic absorption spectrometry [J].
Lobo, Fabiana A. ;
Goveia, Danielle ;
Oliveira, Adriana P. ;
Romao, Luciane P. C. ;
Fraceto, Leonardo F. ;
Dias Filho, Newton L. ;
Rosa, Andre H. .
FUEL, 2011, 90 (01) :142-146
[47]   Determination of lead and cadmium in wines by graphite furnace atomic absorption spectrometry [J].
Kim, M .
FOOD ADDITIVES AND CONTAMINANTS, 2004, 21 (02) :154-157
[48]   Condensation of analyte vapor species in graphite furnace atomic absorption spectrometry [J].
Panichev, NA ;
Ma, Q ;
Sturgeon, RE ;
Chakrabarti, CL ;
Pavski, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (05) :719-731
[49]   DETERMINATION OF LEAD IN CROATIAN WINES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY [J].
Tariba, Blanka ;
Pizent, Alica ;
Kljakovia-Gaspic, Zorana .
ARHIV ZA HIGIJENU RADA I TOKSIKOLOGIJU-ARCHIVES OF INDUSTRIAL HYGIENE AND TOXICOLOGY, 2011, 62 (01) :25-31
[50]   Method development for the determination of chromium and thallium in fertilizer samples using graphite furnace atomic absorption spectrometry and direct solid sample analysis [J].
Borges, Aline R. ;
Francois, Luciane L. ;
Becker, Ernilene M. ;
Vale, Maria Goreti R. ;
Welz, Bernhard .
MICROCHEMICAL JOURNAL, 2015, 119 :169-175