Surface spark-over voltage on solid insulator in sub-cooled liquid nitrogen

被引:2
作者
Chiba, M [1 ]
Nitta, T [1 ]
机构
[1] Univ Tokyo, Dept Elect Engn, Tokyo 1138656, Japan
关键词
bubble; electrical gradient force; solid insulator; sub-cooled liquid nitrogen; surface spark-over voltage;
D O I
10.1109/TASC.2005.849271
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Surface spark-over voltages on solid insulators in boiling and sub-cooled liquid nitrogen are studied under ac, dc and impulse voltage. The insulator structure used is a model of a power cable end. In the structure, static capacitance is formed between outer surface and inner conductor of the insulator. The spark-over voltages for several insulators were measured at gap length 60 mm or less under each voltage waveform. The spark-over voltages increase slightly with increasing gap length in boiling and sub-cooled liquid. In range of shorter gap length spark-over voltages in sub-cooled liquid are higher than those in boiling liquid nitrogen. The differences between spark-over voltages in both liquids are caused by bubbles generated due to discharge at low voltage. The spark-over voltage for the insulator with the larger static capacitance is lower than that for one with the small capacitance.
引用
收藏
页码:1743 / 1746
页数:4
相关论文
共 4 条