A simple and efficient ultrasonic-assisted extraction procedure combined with UV-Vis spectrophotometry for the pre-concentration and determination of folic acid (vitamin B9) in various sample matrices

被引:10
作者
Gurkan, Ramazan [1 ]
Altunay, Nail [1 ]
机构
[1] Cumhuriyet Univ, Dept Chem, Fac Sci, TR-58140 Sivas, Turkey
来源
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT | 2016年 / 33卷 / 07期
关键词
Folic acid; vegetables; silver; ultrasonic-assisted extraction; spectrophotometry; PERFORMANCE LIQUID-CHROMATOGRAPHY; VOLTAMMETRIC DETERMINATION; ELECTROCHEMICAL-BEHAVIOR; GOLD NANOPARTICLES; GAS-CHROMATOGRAPHY; WATER; ION; ELECTRODE; COMPLEX; POWDER;
D O I
10.1080/19440049.2016.1191380
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A simple and efficient ultrasonic-assisted extraction (UAE) procedure has been proposed for the pre-concentration of (2S)-2-[(4-{[(2-amino-4-hydroxypteridin-yl)methyl]amino}phenyl)formamido]pentanedioic acid (folic acid) in vegetables, pharmaceuticals and foods prior to determination at 540nm using UV-Vis spectrophotometry. The method is based on hydrophobic ternary complex formation of folic acid with silver ions in the presence of cetyltrimethylammonium bromide (CTAB) as a sensitivity enhancer counter ion at pH 7.0, and then extraction into a micellar phase of polyethylene glycol monoalkyl ether (Genapol X-080). The impacts on the extraction efficiency and complex formation of analytical parameters such as sample pH, concentration of silver, concentration of surfactants and extraction time, ultrasonic time and sample volume, were investigated and optimised in detail. The matrix effect on the pre-concentration and determination of folic acid was investigated, and it was observed that the proposed method was highly selective against possible matrix co-extractives. Under optimised conditions, a good linear relationship between the analytical signal and folic acid concentration was obtained in the range of 0.6-180gl(-1) with a detection limit of 0.19gl(-1) and quantification limit of 0.63gl(-1). The applicability was evaluated using samples fortified at different concentration levels, and recoveries higher than 94.1% were obtained. The precision as the percent relative standard deviation (RSD%) was in range of 2.5-3.8% (10 and 40gl(-1), n = 5). The proposed method was validated by analysis of two standard reference materials (SRMs) and various real samples, and satisfactory results were obtained.
引用
收藏
页码:1127 / 1138
页数:12
相关论文
共 39 条
[1]   Determination of folic acid in fortified wheat flours [J].
Alaburda, Janete ;
de Almelda, Adriana P. ;
Shundo, Luzia ;
Ruvieri, Valter ;
Sabino, Myrna .
JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2008, 21 (04) :336-342
[2]   Membrane filtration of Sudan orange G on a cellulose acetate membrane filter for separation-preconcentration and spectrophotometric determination in water, chili powder, chili sauce and tomato sauce samples [J].
AlOthman, Zeid A. ;
Unsal, Yunus E. ;
Habila, Mohamed ;
Shabaka, Azza ;
Tuzen, Mustafa ;
Soylak, Mustafa .
FOOD AND CHEMICAL TOXICOLOGY, 2012, 50 (08) :2709-2713
[3]   A simple and efficient electrochemical sensor for folic acid determination in human blood plasma based on gold nanoparticles-modified carbon paste electrode [J].
Arvand, Majid ;
Dehsaraei, Mohammad .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (06) :3474-3480
[4]   Ionic liquid-based dispersive liquid-liquid microextraction combined with high performance liquid chromatography-UV detection for the simultaneous pre-concentration and determination of Ni, Co, Cu and Zn in water samples [J].
Asghari, Alireza ;
Ghazaghi, Mehri ;
Rajabi, Maryam ;
Behzad, Mahdi ;
Ghaedi, Mehrorang .
JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2014, 79 (01) :63-76
[5]   Do low doses of folic acid result in maximum lowering of homocysteine? [J].
Bailey, LB .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 2005, 82 (04) :717-718
[6]   Unmetabolized serum folic acid and its relation to folic acid intake from diet and supplements in a nationally representative sample of adults aged ≥60 y in the United States [J].
Bailey, Regan L. ;
Mills, James L. ;
Yetley, Elizabeth A. ;
Gahche, Jaime J. ;
Pfeiffer, Christine M. ;
Dwyer, Johanna T. ;
Dodd, Kevin W. ;
Sempos, Christopher T. ;
Betz, Joseph M. ;
Picciano, Mary Frances .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 2010, 92 (02) :383-389
[7]   Dietary intake of folate and risk of stroke in US men and women - NHANES I Epidemiologic Follow-up Study [J].
Bazzano, LA ;
He, J ;
Ogden, LG ;
Loria, C ;
Vupputuri, S ;
Myers, L ;
Whelton, PK .
STROKE, 2002, 33 (05) :1183-1188
[8]   Electrochemical determination of hydrochlorothiazide and folic acid in real samples using a modified graphene oxide sheet paste electrode [J].
Beitollahi, Hadi ;
Hamzavi, Mozhdeh ;
Torkzadeh-Mahani, Masoud .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 52 :297-305
[9]   Electrocatalytic and simultaneous determination of isoproterenol, uric acid and folic acid at molybdenum (VI) complex-carbon nanotube paste electrode [J].
Beitollahi, Hadi ;
Sheikhshoaie, Iran .
ELECTROCHIMICA ACTA, 2011, 56 (27) :10259-10263
[10]   STUDIES ON THE HYDROLYSIS OF METAL IONS .29. THE HYDROLYSIS OF THE SILVER ION, AG+, IN ACID SELF-MEDIUM [J].
BIEDERMANN, G ;
HIETANEN, S .
ACTA CHEMICA SCANDINAVICA, 1960, 14 (03) :711-716