Response Time of Thermal Flow Sensors

被引:5
作者
Sosna, C. [1 ]
Walter, T. [1 ]
Lang, W. [1 ]
机构
[1] Univ Bremen, IMSAS Inst Microsensors Actuators & Syst, D-28359 Bremen, Germany
来源
EUROSENSORS XXIV CONFERENCE | 2010年 / 5卷
关键词
Thermal flow sensor; response time measurement;
D O I
10.1016/j.proeng.2010.09.162
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Thermal flow sensors are applied for measurement of instationary flow and for the control of dispensing very small fluid volumes. For these applications, the response time of the sensor must be determined accurately. We investigated three methods for response time determination: a jump of temperature induced by electric heating, a gas velocity step made by a membrane burst and acoustic phase shifts between sound velocity and sound pressure. The measurements have shown that the response time of thermal flow sensors is a function of flow velocity. For stagnant flow, the thermal response time is at about 4.5 ms. With increasing flow, heat transfer rises, thus response time is faster and moves down to about 1 ms. (C) 2010 Published by Elsevier Ltd.
引用
收藏
页码:524 / 527
页数:4
相关论文
共 4 条
[1]  
Buchner R, 2006, PROC IEEE MICR ELECT, P582
[2]   A high-temperature thermopile fabrication process for thermal flow sensors [J].
Buchner, Rainer ;
Sosna, Christoph ;
Maiwald, Marcus ;
Benecke, Wolfgang ;
Lang, Walter .
SENSORS AND ACTUATORS A-PHYSICAL, 2006, 130 :262-266
[3]  
HEDRICH F, 2010, SENS ACTUATO A UNPUB
[4]  
*VOGTL INSTR, GASFL MEAS CONTR MIX